background image

12

501RLC, 1.6mm

Product codes

  

m m

#

Marprene

Bioprene

Pumpsil

 0.5 1/50

112

902.0005.016

903.0005.016

913.0005.016

 0.8 1/32

13

902.0008.016

903.0008.016

913.0008.016

 1.6 1/16

14

902.0016.016

903.0016.016

913.0016.016

 3.2

1/8

16

902.0032.016

903.0032.016

913.0032.016

 4.8 3/16

25

902.0048.016

903.0048.016

913.0048.016

 6.4

1/4

17

902.0064.016

903.0064.016

913.0064.016

 8.0 5/16

18

902.0080.016

903.0080.016

913.0080.016

   

m m

#

Tygon

Fluorel

Neoprene

 0.8 1/32

13

920.0008.016

 1.6 1/16

14

950.0016.016

970.0016.016

920.0016.016

 3.2

1/8

16

950.0032.016

970.0032.016

920.0032.016

 4.8 3/16

25

950.0048.016

970.0048.016

920.0048.016

 6.4

1/4

17

950.0064.016

970.0064.016

920.0064.016

 8.0 5/16

18

950.0080.016

970.0080.016

920.0080.016

501RL2C, 2.4mm

Product codes

  

m m

#

Marprene

Bioprene

Pumpsil

 0.5 1/50

913.A005.024

 0.8 1/32

913.A008.024

 1.6 1/16

119

902.0016.024

903.0016.024

913.A016.024

 3.2

1/8

120

902.0032.024

903.0032.024

913.A032.024

 4.8 3/16

15

902.0048.024

903.0048.024

913.A048.024

 6.4

1/4

24

902.0064.024

903.0064.024

913.A064.024

 8.0 5/16

121

902.0080.024

903.0080.024

913.A080.024

   

m m

#

Chem-Sure

Sta-Pure

 1.6 1/16

119

965.0016.024

960.0016.024

 3.2

1/8

120

965.0032.024

960.0032.024

 4.8 3/16

15

965.0048.024

960.0048.024

 6.4

1/4

24

965.0064.024

960.0064.024

 8.0 5/16

121

965.0080.024

960.0080.024

Note: 2.4mm wall Chem-Sure and Sta-Pure tubing are supplied in 355mm lengths

Содержание 501CC

Страница 1: ...501CC 501cc gb 02 pdf...

Страница 2: ...2 9 8 501F 501P 501X 501V ATEX 501DF 501DP 501DFX 501DV ATEX II 2 G T4...

Страница 3: ...ll not be binding upon Watson Marlow Limited unless expressly approved in writing by a Director or Manager of Watson Marlow Limited Information for returning pumps Equipment which has been contaminate...

Страница 4: ...s through the gearbox foot mounting holes AC Motor Ensure that mains voltage frequency are in accordance with motor nameplate information Secure protective conductor connections If the motor is runnin...

Страница 5: ...igh air humidity aggressive media and large temperature variations will reduce the interval between lubricant changing intervals Select the correct lubricating oil from the table in the back of this o...

Страница 6: ...r line too small x Restricted exhaust x x Poor lubrication x x x x Jammed machine x x x x Compressor too small x x Compressor too far from unit x x PumpSpecifications Control range See pump specificat...

Страница 7: ...d open the hinged guard and swing out the rotor crank handle until it locks into position Select the length of tubing required noting that approximately 240mm is required for the track systems Fit one...

Страница 8: ...guard After the pump has been started open the delivery clamp for a short time so that the tube can find its natural length The 501RLC pumphead is fitted with four position tube clamps to accommodate...

Страница 9: ...ck 3 FN 2341 Hinge screw 4 MN 0266M Hinge grey 5 MNA0114A Tube clamp assembly 6 FN 2332 Screw 7 FN 0422 Screw x 4 8 MN 0011T Main roller 9 MNA0143A 501RLC Rotor assembly 9 MNA0511A 501RL2C Rotor assem...

Страница 10: ...220 EnergolGR XP 100 Mobil gear 629 Shell Omala Oel 100 Bartran HV15 Mobil DTE 11M Shell Tellus Oel T 15 501F RL 501I RL 501TI RL 100ml 601F R 601I R 601TI R 250ml Technical Data 165 165 English Tube...

Страница 11: ...380 60 600 21 213 0 88 8 9 2 6 26 9 0 91 39 400 85 860 130 1400 210 2100 29 291 1 2 12 3 6 36 12 120 54 540 120 1200 180 1900 290 2900 6 62 0 25 2 6 0 74 7 6 2 6 26 11 120 24 250 38 390 60 620 22 223...

Страница 12: ...0048 016 970 0048 016 920 0048 016 6 4 1 4 17 950 0064 016 970 0064 016 920 0064 016 8 0 5 16 18 950 0080 016 970 0080 016 920 0080 016 501RL2C 2 4mm Product codes mm Marprene Bioprene Pumpsil 0 5 1...

Страница 13: ...13 501RLC Flow rates...

Страница 14: ...14 501F R 501DF R 501FX RL 220 250 340 345 230 75 85 62rpm model 223 rpm model...

Страница 15: ...Sta Pure and Chem Sure are trademarks of W L Gore and Associates Warning These products are not designed for use in and should not be used for patient connected applications The information contained...

Страница 16: ...16...

Страница 17: ...ate for each pump returned RGA No 1 Company Address Postcode Telephone Fax Number 3 4 Cleaning fluid to be used if residue of chemical is found during 2 Product servicing 2 1 Serial Number a 2 2 Has t...

Отзывы: