Содержание 500 Series

Страница 1: ...8 6 Safety notes 9 7 Pump specifications 12 7 1 Weights 13 7 2 Pumphead options 13 8 Good pump installation practice 14 8 1 General recommendations 14 8 2 Dos and don ts 15 9 Pump operation 16 9 1 Keypad layout and key IDs 16 9 2 Starting and stopping 17 9 3 Using up and down keys 17 9 4 Maximum speed 17 9 5 Change rotation direction 17 10 Connecting to a power supply 18 10 1 Conductor colour codi...

Страница 2: ...nual 74 17 1 Start 74 17 2 Stop 75 17 3 Increasing and decreasing flow rate 75 18 Flow calibration 77 18 1 Setting the flow calibration 77 19 PROFINET mode 80 19 1 Behaviour on start up 80 19 2 Configure PROFINET settings 80 19 3 PROFINET mode 85 19 4 Pump parameters 85 19 5 GSDML compatibility guide 93 20 Dispense mode 94 20 1 Create a new recipe or edit a recipe 94 20 2 Create a new batch or edi...

Страница 3: ... Pump part numbers 141 28 2 Tubing and element part numbers 142 28 3 Pumphead spares 146 29 Performance data 148 29 1 Performance curves 148 30 Trademarks 153 31 Disclaimers 154 32 Publication history 155 33 List of tables and figures 156 33 1 Tables 156 33 2 Figures 157 Original instructions The original instructions for this manual have been written in English Other language versions of this man...

Страница 4: ...harmonisation legislation Machinery Directive 2006 42 EC EMC Directive 2014 30 EC ROHS Directive 2015 863 6 Harmonised standards used BS EN61010 1 2010 third edition Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General require...

Страница 5: ...ity Management System ISO 9001 and the technical documentation is compiled in accordance with Annex VII B of the Directive We undertake to transmit in response to a reasoned request by the appropriate national authorities relevant information on the partly completed machinery identified above The method of transmission shall be by mail or email The pump head is incomplete and must not be put into ...

Страница 6: ...mponents supplied 530 Components l 530 pump drive unit fitted with pumphead if specified as a pump l The designated power cable attached to the pump drive unit l A 530N module providing pump ingress protection to IP66 NEMA 4X if a PnN l Note the module is attached for transit but must be removed to allow wiring up voltage selection and fuse inspection and then re affixed before the pump is operate...

Страница 7: ...oller and a track on an arc of a circle creating a seal at the point of contact As the roller advances along the tube the seal also advances After the roller has passed the tube returns to its original shape creating a partial vacuum which is filled by fluid drawn from the inlet port Before the roller reaches the end of the track a second roller compresses the tube at the start of the track isolat...

Страница 8: ...d and loss of production This warranty does not obligate Watson Marlow to bear any costs of removal installation transportation or other charges which may arise in connection with a warranty claim Watson Marlow shall not be responsible for shipping damage of returned items Conditions o Products must be returned by pre arrangement to Watson Marlow or a Watson Marlow approved service centre o All re...

Страница 9: ...regulations and guidance This symbol used on the pump and in the manual means An appropriate safety instruction should be followed or caution to a potential hazard exists This symbol used on the pump and in the manual means Do not allow fingers to contact moving parts This symbol used on the pump and in the manual means Caution hot surface This symbol used on the pump and in the manual means Cauti...

Страница 10: ... cable is supplied hardwired into the pump and is not customer replaceable Observe voltage selector switch setting for your region IP66 pumps are supplied with a mains plug The gland at the NEMA Module end of the cable is IP66 rated The mains plug at the opposite end of the cable is NOT IP66 rated It is the user s responsibility to ensure that the connection to the mains supply is IP66 rated This ...

Страница 11: ... per 3 minutes We recommend remote control where a high number of starts is required If the pump is configured to Dispense or PROFINET mode it will respond to remote commands at any time including immediately after power on The pump may operate without any manual intervention e g a remote setpoint could start the pump with no key press required There are moving parts inside the pumphead Before ope...

Страница 12: ...e fluctuation 10 of nominal voltage A well regulated electrical mains supply is required along with cable connections conforming to the best practice of noise immunity Full load current 530 0 6 A 230 V 1 25 A 115 V Fuse rating T2 5AH250V 5x20 mm Installation category overvoltage category II Pollution degree 2 IP 530 IP31 to BS EN 60529 if supplied with N module then IP66 to BS EN 60529 Meets the r...

Страница 13: ... the model and pumphead see on the pump Lifting should be performed according to standard Health and Safety guidelines Finger recesses are built into the sides of the lower shell for convenience in lifting in addition the pump can conveniently be lifted by grasping the pumphead and where fitted the module at the rear of the pump 7 2 Pumphead options Figure 1 530 pump range 520R 520R2 520REH 520REL...

Страница 14: ...hat the direction of rotor rotation is clockwise or counter clockwise whichever is required Please note however that for some pumpheads the tube life will be greater if the rotor rotates clockwise and that performance against pressure will be maximised if the rotor rotates counter clockwise To achieve pressure in some pumpheads the pump must rotate counter clockwise Optimum tube life 4 bar Figure ...

Страница 15: ...e runs with a bore several times larger than the pump tube l Do site the pump at or just below the level of the fluid to be pumped if possible This will ensure flooded suction and maximum pumping efficiency l Do run at slow speed when pumping viscous fluids Flooded suction will enhance pumping performance particularly for materials of a viscous nature l Do recalibrate after changing tubing fluid o...

Страница 16: ...to the last known operating mode FUNCTION keys FUNCTION keys when pressed will perform the function displayed on the screen directly above the relevant function key and keys These keys are used to change the programmable values within the pump These keys are also used to move the selection bar up and down in the menus MODE key To change modes or mode settings press the MODE key The MODE key can be...

Страница 17: ...ng Figure 5 Starting and stopping 9 3 Using up and down keys Figure 6 Using up and down keys 9 4 Maximum speed Figure 7 Maximum speed 9 5 Change rotation direction Figure 8 Change rotation direction m 530pn en 09 02 02 22 17 ...

Страница 18: ... while the module is in place It is mounted in the switch plate at the rear of the pump protected from water by the N Module The module must be removed to allow access to the switch plate Do not switch the pump on unless you have checked that it is set to suit your power supply by removing the module and inspecting the switch and then refitting the module 1 2 3 4 Figure 9 Voltage selector We recom...

Страница 19: ...hite Ground Green Yellow Green 10 2 Wiring the NEMA module PROFINET pumps The NEMA 4X modules fitted to 530 630 and 730 PnN cased pumps have two pairs of wiring ports Two M16 ports are provided together with glands to seal circular cross section cables ranging in diameter from 4 mm to 10 mm 5 32 in to 13 32 in PROFINET connection is via the two M12 connectors mounted to the rear of the NEMA module...

Страница 20: ...f control cables onPROFINET NEMA module 2 No additional control cable earth screening required when EMC gland is used NEMA module with conductive mounting kit for connecting screen to earth for PROFINET 20 m 530pn en 09 02 02 22 ...

Страница 21: ...p installation practice on page 14 are followed 12 PROFINET control wiring Never apply mains power to the D connectors Apply the correct signals to the pins shown Limit signals to the maximum values shown Do not apply voltage across other pins Permanent damage not covered by warranty may result Keep 4 20 mA and low voltage signals separate from mains power Use separate glanded input cables Followi...

Страница 22: ... 8 7 2 1 1 RJ45 connection 1 2 RJ45 connection 2 3 Standard 9 way D Sensor connector Female 4 USB Type A port for service use only 5 Voltage selector switch 6 On Off switch 7 Mains power cable 8 Customer replaceable fuse 22 m 530pn en 09 02 02 22 ...

Страница 23: ...cted flickers to indicate 10 Mbit activity High Low One green LED on for link detected flickers to indicate 100 Mbit activity 12 3 Control wiring Standard 9 way D Sensor connector Female Chassis Skt Recommended control cable 7 0 2 mm 24AWG screened circular The cable screen should be earthed with a 360 deg connection to a conductive back shell AN IP1 PRESSURE_ALARM AN IP2 STOP_START LEAK FREQ EART...

Страница 24: ...ak Clockwise rotation Manual keypad control Wet leak detected Anticlockwise rotation Analogue Table 4 Wiring the D Connector Signal Name Input or output Configurable Signal response 1 5 6 9 0V ANALOGUE 1 Input Yes 1 5 6 9 ANALOGUE 2 0V Input Yes 24 m 530pn en 09 02 02 22 ...

Страница 25: ... Wiring the D Connector Signal Name Input or output Configurable Signal response 1 5 6 9 1KHz FREQ 0V 1 5 6 9 FREQ VAUX 200Hz Input Yes 1 5 6 9 LEAK VAUX VDC 0V 1 5 6 9 LEAK Input Yes m 530pn en 09 02 02 22 25 ...

Страница 26: ... the D Connector Signal Name Input or output Configurable Signal response 1 5 6 9 PRESSURE_ALARM VAUX 1 5 6 9 VDC 0V PRESSURE_ALARM Input Yes 1 5 6 9 STOP VAUX 1 5 6 9 VDC STOP 0V Input Yes 26 m 530pn en 09 02 02 22 ...

Страница 27: ...MA 4X version of the pump otherwise ingress protection may be impaired Ensure that the module cover is correctly secured at all times by all screws supplied Failure to do so may compromise the IP66 NEMA 4X protection Ensure that unused openings on the module are sealed using the blanking plugs provided Failure to do so may compromise the IP66 NEMA 4X protection 1 2 3 4 Figure 13 N Module and F Mod...

Страница 28: ...t connection Adapter PCB Figure 15 Adapter PCB 1 2 U1 1 Without isolated power supply option N Module 2 With isolated power supply option F Module Note Disconnect the adapter module by use of the ribbon eject levers It is recommended to leave the 9W connector permanently attached to the pump Recommended control cable metric 0 05 sq mm 1 31 sq mm solid and stranded USA 30AWG 16AWG solid stranded Ca...

Страница 29: ...minal 24 V and 0 V from the pump internal supplies The F Module option may be used if the sensor requires an isolated supply or has a 4 20 mA output which cannot be used with the ground connected load resistor within the pump Figure 16 Power supply options 22V 0VA ISO 24V 0VA U1 22V 0VA U1 22V ISO 0V 1 2 1 Without isolated power supply option N Module 2 With isolated power supply option F Module m...

Страница 30: ...ockwise rotation Manual keypad control Wet leak detected Anticlockwise rotation Analogue Table 5 Input output Connectors Connector No Function Input or output Configurable Signal response J1 No Connection to pump J2 AN1 P ANALOGUE 1 0VA Input Yes J3 AN2 P ANALOGUE 2 0VA Input Yes 30 m 530pn en 09 02 02 22 ...

Страница 31: ...Function Input or output Configurable Signal response J4 SP LK STOP LEAK 22V SP LK STOP LEAK 22V VDC VDC Input Yes J5 PRESS 0VA PRESS FREQ FREQ VDC PRESS 0VA PRESS FREQ FREQ 22V 200Hz 1KHz Input Yes J6 1 Earth 2 Earth No m 530pn en 09 02 02 22 31 ...

Страница 32: ...equency Repetition rate Fmax 1 10 Hz Leak Stop Pressure Analogue input voltage mode VAin 15 10 30 V 0 10 V range 100R source impedance Analogue input voltage mode RVAin 34 4 kΩ 3 Analogue input measurement range Iin 0 25 mA Analogue input current absolute maximum IAin 50 28 mA Dissipation limit Analogue input voltage absolute maximum VAin 0 7 0 V Dissipation limit Analogue input resistance RIIN 25...

Страница 33: ...12 7 Network topology Figure 17 Star network m 530pn en 09 02 02 22 33 ...

Страница 34: ...Figure 18 Ring network Figure 19 Line topology 34 m 530pn en 09 02 02 22 ...

Страница 35: ...nal connection pair Cable type 100m maximum length With NEMA module Without NEMA module Cable with two connectors ü ü Cable with one additional connector pair ü ü Cable with two additional connector pairs û ü m 530pn en 09 02 02 22 35 ...

Страница 36: ... time 1 Power up the pump The pump displays the start up screen with the Watson Marlow Pumps logo for three seconds 13 1 Selecting the display language 1 Use the keys to select your chosen language and press SELECT 36 m 530pn en 09 02 02 22 ...

Страница 37: ...will now be displayed on screen Choose CONFIRM to continue All text will now appear in your chosen language 3 Choose REJECT to return to the language choice screen This then proceeds to the home screen m 530pn en 09 02 02 22 37 ...

Страница 38: ...onfigured to Dispense or PROFINET mode it will respond to remote commands at any time including immediately after power on The pump may operate without any manual intervention e g a remote setpoint could start the pump with no key press required The pump is preset with operational parameters as shown in table below Table 8 First time start up defaults Parameter 530 default Language Not set Default...

Страница 39: ...sume interrupted OFF The pump is now ready to operate according to the defaults listed above Note The display background colour changes according to running state as follows l White background indicates pump stopped l Grey background indicates pump running l Red background indicates error or alarm All operating parameters may be changed by means of key presses see section Pump operation on page 16...

Страница 40: ...l jump from the start up screen to the home screen l The pump runs a power on test to confirm proper functioning of the memory and hardware If a fault is found an error code is displayed l The pump displays the start up screen with the Watson Marlow Pumps logo for three seconds followed by the home screen l Start up defaults are those in place when the pump was switched off last Check that the pum...

Страница 41: ...ess the MENU button from one of the HOME screens or INFO screens 2 This will display the MAIN MENU as shown below Use the keys to move the selection bar between the available options 3 Press SELECT to choose an option m 530pn en 09 02 02 22 41 ...

Страница 42: ...4 Press EXIT to return to the screen from where the MENU was called 15 1 Security settings Security settings can be changed by selecting SECURITY SETTINGS from the Main menu 42 m 530pn en 09 02 02 22 ...

Страница 43: ...e padlock icon will appear on the operating mode home screen to show that keypad lock is activated 4 Note that the STOP key will always work whether the keypad is locked or not PIN protection Using the keys select PIN protection from the SECURITY SETTINGS menu and press ENABLE DISABLE to switch on off the PIN protection If PIN protection has been enabled a Master level PIN will be required to disa...

Страница 44: ...hey will be able to access this functionality by entering a PIN code assigned to them by the Master user 1 To set the Master PIN scroll to Master level and press ENABLE 2 To define a four digit Master PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER 44 m 530pn en 09 02 02 22 ...

Страница 45: ...ou require Press CHANGE to return to PIN entry 4 The following screen will be displayed to indicate that the Master PIN has been applied to access all functionality Press NEXT to selectively enable functionality access for User 1 and User 2 m 530pn en 09 02 02 22 45 ...

Страница 46: ...1 security settings or scroll to configure an alternative User 2 ENABLE user 1 security settings displays the PIN entry screen for User 1 To define a four digit User 1 PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER 46 m 530pn en 09 02 02 22 ...

Страница 47: ...fine the allowed functionality use the keys to select the functionality and press ENABLE User 1 PIN will allow access to only the enabled functionality to disable functionality highlight the enabled functionality and press DISABLE When all the required functionality has been enabled press FINISH m 530pn en 09 02 02 22 47 ...

Страница 48: ...2 security settings or scroll to configure an alternative User 2 ENABLE user 2 security settings displays the PIN entry screen for User 2 To define a four digit User 2 PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER 48 m 530pn en 09 02 02 22 ...

Страница 49: ...Security Settings for User 1 and User 2 have been set by the Master only the Master PIN will allow access to Security Settings 4 The HOME screen will be displayed A PIN is now required to access all functionality The Master PIN accesses all pump functionality and the User 1 and User 2 PINs access only the defined functionality To enter the PIN use the keys to select each digit from 0 9 Once you ha...

Страница 50: ...yed NOTE this screen will also display if the PIN entered does not allow access to that functionality 6 If a PIN number is entered that is already in use the following screen will be displayed press CHANGE to input an alternative PIN or EXIT to abort 50 m 530pn en 09 02 02 22 ...

Страница 51: ...allow access to the functionality the following screen will be displayed Keypad beep 1 From SECURITY SETTINGS scroll to Keypad beep using the keys and select ENABLE The pump will now beep at every key press m 530pn en 09 02 02 22 51 ...

Страница 52: ...ore the pump will enter the home control screen Disabling this feature does not change any other aspects of PIN code operation Anyone wishing to modify pump settings will still need to enter the PIN code 15 2 General settings To view the general settings menu select GENERAL SETTINGS from the main menu Auto restart This pump includes a feature called Auto Restart When Auto Restart is enabled it wil...

Страница 53: ...number of starts is required If the pump is configured to Dispense or PROFINET mode it will respond to remote commands at any time including immediately after power on The pump may operate without any manual intervention e g a remote setpoint could start the pump with no key press required Flow units The current chosen flow unit is displayed on the right hand side of the screen To change flow unit...

Страница 54: ...abel which is displayed in the header bar of the home screen To define or edit the pump label move the selection bar over the Pump label menu entry and press SELECT If a pump label has been previously defined this will be displayed on screen to allow editing otherwise it will display the default label WATSON MARLOW 1 Use the keys to scroll through the available characters for each digit The availa...

Страница 55: ...eneral settings menu Asset number The Asset number is for users to set a unique asset identification code for the pump This can help to track pumps on the network and distinguish between different pumps on the network There is no default factory setting for this parameter and new pumps are supplied without an asset number m 530pn en 09 02 02 22 55 ...

Страница 56: ...Setting up the asset number 1 From the main menu using the keys scroll to General settings and press SELECT 2 Using the keys scroll to Asset number and press SELECT 56 m 530pn en 09 02 02 22 ...

Страница 57: ...Using the keys enter a character 4 There are 20 character slots Press NEXT to confirm your character and to move onto the next Press PREVIOUS to return to the last character slot m 530pn en 09 02 02 22 57 ...

Страница 58: ...g in the event of an error Example disconnect the RJ45 cable from the pump while running on PROFINET mode and the pump will error l If failsafe speed is enabled the pump will run at the failsafe speed and the network error message will display l If failsafe speed is not enabled the pump will stop running and the network error message will display Once the error is acknowledged the pump will run as...

Страница 59: ...the keys to move the selection bar over Pumphead type and press SELECT The following screen will be displayed 3 Use the keys to move the selection bar over Pumphead and press SELECT m 530pn en 09 02 02 22 59 ...

Страница 60: ...lection bar over the required pumphead type and press SELECT Tube size and tube material 1 Select Tube size from GENERAL SETTINGS then use the keys to move the selection bar over Bore size and press SELECT 60 m 530pn en 09 02 02 22 ...

Страница 61: ...se the keys to move the selection bar over the tube size to be used and press SELECT 3 If a LoadSure element has been selected then the tube size is displayed as pressure and bore m 530pn en 09 02 02 22 61 ...

Страница 62: ...the selection bar over the tube material to be used and press SELECT 6 The PUMPHEAD MODEL screen allows the tube Lot Number to be recorded for future reference Using the keys scroll to Tube lot number and press SELECT 7 Use the keys to scroll through the available characters for each digit The available characters are 0 9 A Z and SPACE 62 m 530pn en 09 02 02 22 ...

Страница 63: ...8 Press NEXT to move onto the next character or PREVIOUS to move back to the last character 9 Press FINISH to save the entry and return to the general settings menu m 530pn en 09 02 02 22 63 ...

Страница 64: ...onfirmation screens to ensure that this function is not carried out in error 3 Press CONFIRM followed by RE CONFIRM to restore the defaults Language 1 Select language from the GENERAL SETTINGS menu to choose an alternative display language for the pump The pump must be stopped before changing the language 64 m 530pn en 09 02 02 22 ...

Страница 65: ...inue all displayed text will now appear in your chosen language 4 Press REJECT to return to the language choice screen 15 3 Change mode Selecting CHANGE MODE menu from the main menu will navigate you to access the sub menu shown below This is the same as pressing the MODE key Please see Mode menu on page 73 for further details m 530pn en 09 02 02 22 65 ...

Страница 66: ...menu to define a lower maximum speed limit for the pump This speed limit will be applied to all operating modes 2 Use the keys to adjust the value and press SAVE to set Reset run hours 1 Select Reset run hours from the CONTROL SETTINGS menu 2 Select RESET to zero the run hours counter The run hours counter can be viewed by pressing INFO from your home screen The following screen will be displayed ...

Страница 67: ... keys and press SELECT to choose which input to configure 3 Use the keys and press SELECT to choose the logic state of the chosen input 4 Press SELECT to program the output or BACK to cancel 5 NOTE On this model Inputs 4 and 5 are configured for a pressure sensor m 530pn en 09 02 02 22 67 ...

Страница 68: ...e the remote stop input when the pump is in Manual mode by using the following sequence to configure the start stop settings 2 The default is û The start stop input is not disabled in Manual mode Press SELECT to change the setting to ü 68 m 530pn en 09 02 02 22 ...

Страница 69: ...3 Press HOME to return and store the setting The input is now disabled in Manual mode m 530pn en 09 02 02 22 69 ...

Страница 70: ... 1 The setting is ü The start stop input is disabled Press SELECT to open the logic state menu 2 Use the keys and press SELECT to choose the logic state of the chosen input for your connected control hardware 70 m 530pn en 09 02 02 22 ...

Страница 71: ...3 Press HOME to return and store the setting The input is now enabled in Manual mode m 530pn en 09 02 02 22 71 ...

Страница 72: ...15 6 Help Help 1 Select Help from the main menu to access the help screens 72 m 530pn en 09 02 02 22 ...

Страница 73: ...CHANGE MODE menu 2 Use the keys to scroll through the available modes l Manual default l Flow Calibration l PROFINET l Dispense l BACK 3 Use SELECT to choose mode Use the right hand function key to alter mode settings m 530pn en 09 02 02 22 73 ...

Страница 74: ...s when the power is re applied When the pump is running it displays an animated clockwise arrow In normal operation the direction of flow is into the bottom port of the pumphead and out of the top port If an exclamation mark is displayed it indicates that the pump could automatically restart at any time In Manual mode the Auto Restart behaviour is configurable If a padlock icon shows it indicates ...

Страница 75: ...ess will decrease flow rate by the least significant digit of the chosen flow rate unit l Repeat key presses as required to achieve the desired flow rate l Hold down the key for flow rate scrolling Increasing flow rate l A single key press will increase flow rate by the least significant digit of the chosen flow rate unit l Repeat key presses as required to achieve the desired flow rate l Hold dow...

Страница 76: ...only 1 Using the MAX key l Press and hold the MAX key to run at maximum flow l Release the key to stop the pump l The volume pumped and time elapsed are displayed while the MAX key is pressed and held 76 m 530pn en 09 02 02 22 ...

Страница 77: ... pump displays flow rate in ml min 18 1 Setting the flow calibration 1 Using the keys scroll to Flow calibration and press CALIBRATE 2 Using the keys enter the maximum flow rate limit and press ENTER m 530pn en 09 02 02 22 77 ...

Страница 78: ...3 Press START to begin pumping a volume of fluid for calibration 4 Press STOP to stop pumping fluid for the calibration 78 m 530pn en 09 02 02 22 ...

Страница 79: ...ys to enter the actual volume of fluid pumped 6 To accept the new calibration press ACCEPT or RE CALIBRATE to repeat the procedure Press HOME or MODE to abort 7 The pump is now calibrated m 530pn en 09 02 02 22 79 ...

Страница 80: ...alent parameters viewed on the TFT screen or over the web interface are not cleared New connections may be established without needing to reboot the pump By default the motor will stop upon losing connection but this behaviour can be customised using the failsafe settings Mains power on The I O data of all sub modules as viewed over PROFINET will be cleared to zeroes This does not clear the parame...

Страница 81: ...1 Press the MODE key to access the MODE menu 2 Use the keys to select PROFINET m 530pn en 09 02 02 22 81 ...

Страница 82: ...s the PROFINET SETTINGS menu Setting DHCP Enable 1 Press the DISABLE key to set DHCP Enable to Off Setting the IP Address Subnet mask and Gateway address Configure each of the IP Address subnet mask and gateway address in turn using the following method 82 m 530pn en 09 02 02 22 ...

Страница 83: ...e SET ADDRESS menu 2 Use the keys to set the first number Hold the key increase the scrolling speed Press NEXT to move to the next number 3 After setting the last number press CONFIRM to store the number and return to the PROFINET SETTINGS screen m 530pn en 09 02 02 22 83 ...

Страница 84: ...4 Press BACK to return to the MODE MENU 84 m 530pn en 09 02 02 22 ...

Страница 85: ... below if the pump is not connected to a PROFINET controller 3 If the pump is connected to a PROFINET controller press INFO to display the network settings 19 4 Pump parameters All available pump parameters are grouped in to modules as listed below l Pump Details and set up l Pump Status l Pump Control l Errors and Warnings l Dispense m 530pn en 09 02 02 22 85 ...

Страница 86: ...oint μL min Read SInt32 Displays the Flow low alarm band set point in μL min 24 Flow max alarm setpoint μL Read SInt32 Displays the Flow high alarm band set point in μL min 35 Tube wall size mm Read UInt8 Enum Displays the currently selected tube wall size See Wallsize enumeration table 36 Tube bore size mm Read UInt8 Enum Displays the currently selected tube bore size See BoreSize enumeration tab...

Страница 87: ...value if the flow sensor is setup 16 Sensor pressure deciPSI Read SInt32 Reports a value if the pressure sensor is setup 25 Total volume pumped μL Read UInt32 Displays the totalised flow value 26 Pump Head revolution count Read UInt32 Displays the revolution count in full rotations 27 Current pump speed deciRPM Read UInt16 Displays the current pump speed set point 28 Pump speed limit deciRPM Read ...

Страница 88: ...ailsafeSpeed parameter Bit 1 Set pump direction to anti clockwise If set the pump will run anti clockwise Pump defaults to clockwise rotation Bit 2 Start pump Set to 1 true to allow the pump to run 0 will stop the pump Note that pump enable needs to be set Bit 3 Enable pump Need to set to 1 to allow pump to run Setting to 0 will stop the pump and not allow the pump to run Bit 4 Reset pump run hour...

Страница 89: ...as a speed error Please follow onscreen instructions Bit 3 Over Current error active If set the pump has an over current error Please follow onscreen instructions Bit 4 Over voltage error active If set the set the pump has an over voltage error Please follow onscreen instructions Bit 5 Guard open If set then the guard has been opened Please follow onscreen instructions to clear Bit 6 Flow sensor e...

Страница 90: ...ensor low warning is active Bit 4 Pressure sensor max alarm active if set the pressure sensor high alarm is active Bit 5 Pressure sensor min alarm active If set the pressure low alarm is active Bit 6 Pressure sensor max warning active If set the pressure high warning is active Bit 7 Pressure sensor min warning active If set the pressure sensor low warning is active Bit 0 Pressure switch active if ...

Страница 91: ...s the current batch end delay 88 Active Recipe Start Delay deciSeconds Read UInt16 Reports the current recipe start delay 89 Active Recipe End Delay deciSeconds Read UInt16 Reports the current recipe end delay 90 Current Dispense Doses Delivered Read UInt16 Reports the current number of doses delivered 92 Active Recipe Anti Drip Amount Read Uint8 Reports the current anti drip amount 93 Current Dis...

Страница 92: ... end of the batch 75 Edit recipe start delay deciSeconds Write UInt16 Set the time delay between the start of the dose and the pump head startting 76 Edit recipe end delay deciSeconds Write UInt16 set the time delay between the pump head stopping and the end of the dose 78 Set batch dispense direction anti clockwise Write UInt8 Set batch pump direction to anti clock wise if set 79 Edit recipe anti...

Страница 93: ...ftware versions Version comments GSDML V2 4 Watson Marlow 530_ 630_730 Profinet Pump 20211116 xml January 2021 530Pn 630Pn 730Pn 0 41 03 Initial GSDML release Link to GSDML file location 1 Navigate to https www wmftg com en literature other resources software and devices Notes 1 If your pump software is compatible with multiple GSDML files versions it is recommended to use the latest version avail...

Страница 94: ...ode 1 Create a new recipe or edit a recipe below 2 Create a new batch or edit a batch on page 98 3 Set the active batch on page 102 4 Start dispensing on page 104 20 1 Create a new recipe or edit a recipe Note the pump must be stopped to enter DISPENSE SETTINGS 1 Press MODE to display the CHANGE MODE menu 94 m 530pn en 09 02 02 22 ...

Страница 95: ...2 Using the keys scroll to Dispense and press SETTINGS 3 Using the keys scroll to Recipes and press SELECT m 530pn en 09 02 02 22 95 ...

Страница 96: ...screen is displayed Alternatively scroll to a recipe name and press SELECT to edit that recipe The EDIT RECIPE screen is displayed Press SELECT to edit a parameter Set each parameter to the desired value See Recipe parameters on page 107 for a description of the parameters 96 m 530pn en 09 02 02 22 ...

Страница 97: ...ry field press FINISH to store the entry 6 Use the key to highlight any of the remaining parameters and press SELECT 7 Use the keys to adjust the value as desired and press SET 8 If you have created a new recipe highlight Save and press SELECT 9 If you have edited an existing recipe highlight Save and press SELECT to overwrite or to save as a new recipe highlight Save as and press SELECT 10 Press ...

Страница 98: ...e a new batch or edit a batch Note the pump must be stopped to enter DISPENSE SETTINGS 1 Press MODE to display the CHANGE MODE menu 2 Using the keys scroll to Dispense and press SETTINGS 98 m 530pn en 09 02 02 22 ...

Страница 99: ... Batches and press SELECT 2 Highlight Add new batch and press SELECT to create a new batch or highlight a batch name and press SELECT to edit that batch The EDIT BATCH screen is displayed m 530pn en 09 02 02 22 99 ...

Страница 100: ... character Press NEXT to confirm your character and to move onto the next Press PREVIOUS to move the cursor back one character Move the cursor to the end or beginning of the entry field using NEXT or PREVIOUS When the cursor is at the beginning or end of the entry field press FINISH to store the entry 5 Use the keys to highlight Active Recipe and press SELECT 100 m 530pn en 09 02 02 22 ...

Страница 101: ...h highlight Save and press SELECT 8 If you have edited an existing batch highlight Save and press SELECT to overwrite or to save as a new batch highlight Save as and press SELECT 9 Press FINISH to confirm This will complete the editing save and return to the BATCH screen m 530pn en 09 02 02 22 101 ...

Страница 102: ... Set the active batch Note the pump must be stopped to enter DISPENSE SETTINGS 1 Press MODE to display the CHANGE MODE menu 2 Using the keys scroll to Dispense and press SETTINGS 102 m 530pn en 09 02 02 22 ...

Страница 103: ...1 Using the keys scroll to Active batch and press SELECT 2 Choose the batch from the list of created batches and press SELECT to confirm m 530pn en 09 02 02 22 103 ...

Страница 104: ...ll display the DISPENSE screen 1 3 4 2 DISPENSE screen 1 Target volume 2 Batch name 3 Batch Progress Icon The left hand number is the number of dispenses completed the right hand number is the batch size If Batch size set to Unlimited only the number of dispenses completed is shown 4 Flow rate 104 m 530pn en 09 02 02 22 ...

Страница 105: ...ng pressing this has no effect Info Pressing the INFO function key will display further information End batch 1 Pause the batch i If a Batch size has been entered the batch will pause automatically when the number of fills completed equals the batch size ii If a Batch size is unlimited or to end a batch early press STOP Once the current fill has been completed the batch will pause m 530pn en 09 02...

Страница 106: ...tive batch Batch to be dispensed Select from a list of created batches To create a new batch refer to Create a new batch or edit a batch on page 98 Batches A batch contains the batch size active recipe direction and start and end delay You must create at least one batch and set it as the active batch before Dispense can start Batch parameters Configure the following parameters 106 m 530pn en 09 02...

Страница 107: ...mp may be set up so that the direction of rotor rotation is clockwise or counter clockwise whichever is required Please note however that for some pumpheads the tube life will be greater if the rotor rotates clockwise and that performance against pressure will be maximised if the rotor rotates counter clockwise To achieve pressure in some pumpheads the pump must rotate counter clockwise Start dela...

Страница 108: ... direction of pumphead Anti drip is measured by the number of reverse steps 0 10 Anti drip values are whole numbers between 0 and 10 where 10 is one complete reverse revolution of the rotor and 0 is no reverse revolution of the rotor When using anti drip prime the pump before starting each new batch This will compensate for the volume of fluid that has been retracted due to anti drip Note To reduc...

Страница 109: ... the numerical position in the list of recipes to identify a recipe Deleting a recipe may change that numerical position After deleting a recipe check your batch to make sure the assigned recipe is correct Note The last remaining recipe cannot be deleted Dose adjust Adjust the recipe volume by 50 Applies adjustment to any active recipe Set the value to 100 to use the volume defined in the recipe S...

Страница 110: ... the procedure in Create a new recipe or edit a recipe on page 94 and Create a new batch or edit a batch on page 98 2 Leave the pump in Dispense mode and have the correct batch active Set the active batch on page 102 3 Lock the control of the pump using the PIN function PIN protection on page 43 4 Start stop the pump using PROFINET control 22 Sensors Sensors can be connected to the pump to display...

Страница 111: ...e sensor is correctly wired to the pump before proceeding with set up Control wiring on page 23 or Input output connectors on page 30 PUMP SENSOR Figure 21 Sensor wiring PUMP SENSOR Figure 22 Sensor wiring m 530pn en 09 02 02 22 111 ...

Страница 112: ...ng up the sensors 1 From the CONTROL SETTINGS menu using the keys scroll to Sensor settings option and press SELECT 2 Using the keys scroll to Configure sensors option and press SELECT 112 m 530pn en 09 02 02 22 ...

Страница 113: ... SELECT This selects the type of sensor to configure 4 A list of supported flow sensor families are displayed The example in the image above shows supported flow sensors Using the keys scroll to the desired flow sensor and press SELECT m 530pn en 09 02 02 22 113 ...

Страница 114: ...5 The input that the sensor is attached to needs to be assigned 6 Using the keys scroll to the desired flow sensor and press SELECT 114 m 530pn en 09 02 02 22 ...

Страница 115: ...l to the desired sensor size and press SELECT 9 Using the keys scroll to the desired output unit and press SELECT 10 This choice will alter the units displayed on the home screen Set Alarm and Warning level 1 Using the keys scroll to the alarm level to set up and press SELECT m 530pn en 09 02 02 22 115 ...

Страница 116: ...ss SELECT to store Each one of these defaults to none once the user sets a value in the edit screens the alarm warning will become active 3 When a warning level is triggered the top or bottom bars will show orange 116 m 530pn en 09 02 02 22 ...

Страница 117: ... will stop 22 3 Start up delay Sets the delay from the motor starting to the alarms warnings activating Start up delay activates on a motor start irrelevant of mode includes MAX 1 From the control settings menu using the keys scroll to Sensor settings option and press SELECT m 530pn en 09 02 02 22 117 ...

Страница 118: ...ELECT 3 Using the keys set a value and press SELECT to store 22 4 Generic sensors Generic Sensors allow any sensor with a 4 20 mA output and a linear response to be used on the system The sensor max flow pressure ratings are shown in a table at the end of this section 118 m 530pn en 09 02 02 22 ...

Страница 119: ...1 From the control settings menu using the keys scroll to Sensor settings option and press SELECT 2 Using the keys scroll to Configure sensors option and press SELECT m 530pn en 09 02 02 22 119 ...

Страница 120: ...croll to Flow or Pressure option and press SELECT This selects the type of sensor to configure 4 Using the keys scroll to Generic flow sensor or Generic pressure sensor option and press SELECT 120 m 530pn en 09 02 02 22 ...

Страница 121: ...r has connected the sensor to See PROFINET control wiring on page 21 section for connection specifications Only generic sensors which provide a 4 20 mA output are supported 6 Using the keys select the sensor unit output type and press SELECT Options in table below depending on sensor type selection m 530pn en 09 02 02 22 121 ...

Страница 122: ... Flow Pressure ul min Bar ml min Psi ml hr l min l min 7 After selecting the sensor unit type the user will progress onto the GENERIC SENSOR VALUES screen 8 Using the keys scroll to Set 4mA value 122 m 530pn en 09 02 02 22 ...

Страница 123: ...9 Using the keys change the value reported when the sensor input is at 4 mA Once satisfied with the value press SELECT 10 Using the keys scroll to Set 20mA value m 530pn en 09 02 02 22 123 ...

Страница 124: ... Minimum Maximum PSI 10 0 75 Bar 0 689 5 171 Table 21 Sensor flow limits Flow Unit Minimum Maximum ul min 0 60000000 ml min 0 60000 ml hr 0 900000 l min 0 60 l hr 0 900 Alarm warning levels The Warning error levels screen will then be shown refer to Set Alarm and Warning level on page 115 The error and warning values will default to the value set at 4 mA and 20 mA The user should set up warnings a...

Страница 125: ...ing event is indicated by the dashed lines WL WH on the graph During a warning event the pump will show orange sections on the screen and a warning bit will flag on the Ethernet communications This event is triggered by the sensor signal being equal to or greater than the value set by the Warning Max Min or Ethernet Hi Lo Lo Hi Parameters Note It is normal to expect fluctuations in both pressure a...

Страница 126: ...Procedure 1 From the GENERIC SENSOR VALUES screen 2 Using the keys scroll to Alarm warning levels 126 m 530pn en 09 02 02 22 ...

Страница 127: ...ys select the value to change and press SELECT 4 Using the keys scroll to the desired value and press SELECT 5 Press BACK to store the changes and return to the GENERIC SENSOR VALUES screen m 530pn en 09 02 02 22 127 ...

Страница 128: ...to 1 2 where 1 will result in no change to the slope 1 2 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 mA y2 y1 y B A C 3 Figure 24 Set slope adjust A Sensor configuration determined by the 4mA value and 20mA value B Set slope adjust is greater than 1 C Set slope adjust is less than 1 y1 4mA value Generic sensors on page 118 y2 20mA value Generic sensors on page 118 128 m 530pn en 09 02 02 22 ...

Страница 129: ...Procedure 1 From the GENERIC SENSOR VALUES screen 2 Using the keys scroll to Set slope adjust m 530pn en 09 02 02 22 129 ...

Страница 130: ...mA range of the channel and not affect the slope B A C 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 mA y2 y1 y Figure 25 Set offset adjust A Sensor configuration determined by the 4mA value and 20mA value B Set offset adjust is greater than 1 C Set offset adjust is less than 1 y1 4mA value y2 20mA value 130 m 530pn en 09 02 02 22 ...

Страница 131: ...Procedure 1 From the GENERIC SENSOR VALUES screen 2 Using the keys scroll to Set offset adjust m 530pn en 09 02 02 22 131 ...

Страница 132: ...3 Using the keys scroll to the desired value and press SELECT 22 5 Flow sensor reading 1 The flow sensor value can be read via the Flow sensor reading screen 132 m 530pn en 09 02 02 22 ...

Страница 133: ... of rotation l Check that the rotor is not slipping on the drive shaft If the pump turns on but will not run l Check the remote stop function and configuration l Check the mode you are in are you in Analog mode l Try to operate and run the pump in Manual mode 23 1 Error codes If an internal error occurs an error screen with a red background is displayed Note Signal out of range over signal and lea...

Страница 134: ...top pump immediately Check supply Power OFF ON may reset Er17 Under voltage Stop pump immediately Check supply Power OFF ON may reset Er20 Signal out of range Check analog control signal range Trim signal as required Or seek support Er21 Over signal Reduce the analog control signal Err50 Communication error internal pump communications error and not a network error Attempt to reset by switching po...

Страница 135: ...24 Drive maintenance There are no user serviceable parts inside the pump Please contact your local Watson Marlow representative to arrange repair m 530pn en 09 02 02 22 135 ...

Страница 136: ...t MN2513B PROFINET Cable M12D Right Angle 4 pin plug to M12D Straight 059 9126 000 PROFINET Cable M12D Right Angle 4 pin plug to RJ45 CAT 5 S 059 9127 000 PROFINET Cable RJ45 to RJ45 CAT 5e SHIELDED 3m 059 9128 000 M12 cover MN2943B M12 collars insulated MN2934T M12 collars non insulated MN2935T RJ45 skt TO M12 D CODE skt ADAPTER IP68 059 9124 000 Leak Detector Kit for 530 En 059 9151 000 Leak Det...

Страница 137: ...he tool lockable pumphead track Secondary backup protection is provided in the form of an optional guard switch which stops the pump if the pumphead track is opened The optional guard switch on cased pumps should never be used as primary protection Always disconnect the mains power supply to the pump before opening the pumphead guard 26 1 520R pumphead replacement 1 2 3 4 5 6 m 530pn en 09 02 02 2...

Страница 138: ...m the mains power supply before opening any guard or track or performing any positioning removal or maintenance operation 27 1 Continuous tubing 520R and 520R2 1 2 3 4 5 6 7 8 9 505L 1 2 3 4 5 6 8 0 mm 145 mm 9 6 mm 150 mm 138 m 530pn en 09 02 02 22 ...

Страница 139: ... 30 psi Up to 4 bar 60 psi Up to 7 bar 100 psi Purple Maxthane tubing 3 2 mm Up to 7 bar 100 psi 6 4 mm Up to 4 bar 60 psi 9 6 mm Up to 2 bar 30 psi 520REL 520REM 520REH and 520RET 1 2 3 4 5 530 Sanitary connectors 1 2 3 m 530pn en 09 02 02 22 139 ...

Страница 140: ...ap and clutch boot exposure to less than one minute risk of attack Halogenated chlorinated solvents Not recommended possible risk to polycarbonate tube clamp adjusters and polypropylene tube clamp locators Alcohols general No precaution necessary Glycols Minimize rotor cap and clutch boot exposure to less than one minute risk of attack Estersolvents Remove guard Minimize rotor cap and tube clamp l...

Страница 141: ...EU mains plug A American mains plug K Australia mains plug R Argentina mains plug C Swiss mains plug D India South Africa mains plug B Brazilian mains plug For non profibus and EtherNet IP pumps this option has an engineered product code consult factory for more information Only available with American mains plug U and Du models only Special NEMA module 059 919F 100 PROFINET Watertight Module 530F ...

Страница 142: ...016 8 0 5 16 18 902 0080 016 933 0080 016 966 0080 016 mm inch STA PURE Series PCS Neoprene 0 8 1 32 13 920 0008 016 1 6 1 16 14 920 0016 016 3 2 1 8 16 961 0016 016 920 0032 016 4 8 3 16 25 961 0032 016 920 0048 016 6 4 1 4 17 961 0048 016 920 0064 016 8 0 5 16 18 961 0064 016 920 0080 016 mm inch Pumpsil 0 5 1 50 112 913 A005 016 0 8 1 32 13 913 A008 016 1 6 1 16 14 913 A016 016 3 2 1 8 16 913 A...

Страница 143: ...RE Series PFL STA PURE Series PCS 0 8 1 32 1 6 1 16 119 966 0016 024 961 0016 024 3 2 1 8 120 966 0032 024 961 0032 024 4 8 3 16 15 966 0048 024 961 0048 024 6 4 1 4 24 966 0064 024 961 0064 024 8 0 5 16 121 966 0080 024 961 0080 024 Note 2 4 mm wall STA PURE Series PFL and STA PURE Series PCS tubing are supplied in 355 mm lengths Table 27 2 4 mm wall elements for 520RE pumpheads 0 2 bar 0 30 psi ...

Страница 144: ...4 1 4 17 933 0064 PFT 913 A064 PFT 961 0064 PFT 966 0064 PFT 9 6 3 8 122 933 0096 PFT 913 A096 PFT 961 0096 PFT 966 0096 PFT Table 28 2 4 mm wall elements for 520RE pumpheads 2 4 bar 30 60 psi pressure rated elements Industrial mm inch Marprene TM 3 2 1 8 16 902 P032 PFQ 6 4 1 4 17 902 P064 PFQ Sanitary mm inch Bioprene TM STA PURE Series PCS 3 2 1 8 16 933 P032 PFT 961 M032 PFT 6 4 1 4 17 933 P06...

Страница 145: ... 31 1 6 mm wall elements for 520RET pumpheads 0 2 bar 0 30 psi pressure rated elements Sanitary mm inch Maxthane 9 6 3 8 122 945 0096 PFT Table 32 1 6 mm wall elements for 520RET pumpheads 0 4 bar 0 60 psi pressure rated elements Sanitary mm inch Maxthane 6 4 1 4 17 945 0064 PFT Table 33 1 6 mm wall elements for 520RET pumpheads 0 7 bar 0 100 psi pressure rated elements Sanitary mm inch Maxthane 3...

Страница 146: ...1 ET0 520RET 1 MNA2050A 520R 520R2 Pumphead guard complete with tool unlockable latch 2 MNA2045A 520R 520R2 Track assembly for cased pumps complete with spring loaded tube clamps 3 MNA2043A 520R 1 6 mm wall tube Rotor assembly complete with pumping rollers follower rollers and tube guide rollers MNA2001A 520R2 2 4 mm wall tube MNA2138A grey 520REL MNA2139A beige 520REM MNA2140A blue 520REH MNA2456...

Страница 147: ...2 MN2131M 520RE 5 MNA2005A 520R 520R2 Top RH tube clamp MN2002M 520R 520R2 Tube clamp location plug 6 MN2034B Guard latch spring MN2005M Guard latch spring cartridge 7 MNA2147A 520RE Pumphead guard complete with seal and tool lockable latch 8 MNA2144A 520RE Track assembly for cased pumps 9 MN2023T and MN2003T 520RE Drain port and nut m 530pn en 09 02 02 22 147 ...

Страница 148: ...ure 26 Marprene continuous tubing 1 6 mm wall 200 rpm clockwise rotation ml min 1 500 1000 1500 2000 2500 0 0 5 1 1 5 2 1 6 mm 8 0 mm 3 2 mm 4 8 mm 6 4 mm Suction bar Pressure bar Figure 27 Marprene continuous tubing 1 6 mm wall 200 rpm counter clockwise rotation ml min 1 500 1000 1500 2000 2500 0 0 5 1 1 5 2 1 6 mm 8 0 mm 3 2 mm 4 8 mm 6 4 mm Suction bar Pressure bar 148 m 530pn en 09 02 02 22 ...

Страница 149: ...00 0 0 5 1 1 5 2 1 6 mm 9 6 mm 8 0 mm 3 2 mm 4 8 mm 6 4 mm Suction bar Pressure bar Figure 29 Marprene continuous tubing 2 4 mm wall 200 rpm counter clockwise rotation ml min 1 500 1000 1500 2000 2500 3000 3500 0 0 5 1 1 5 2 1 6 mm 9 6 mm 8 0 mm 3 2 mm 4 8 mm 6 4 mm Suction bar Pressure bar m 530pn en 09 02 02 22 149 ...

Страница 150: ...000 1500 2000 2500 3000 3500 0 0 5 1 1 5 2 3 2 mm 6 4 mm 9 6 mm Suction bar Pressure bar Figure 31 Sta Pure element 0 2 bar 0 30 psi 200 rpm counter clockwise rotation ml min 1 500 1000 1500 2000 2500 3000 3500 0 0 5 1 1 5 2 3 2 mm 6 4 mm 9 6 mm Suction bar Pressure bar 150 m 530pn en 09 02 02 22 ...

Страница 151: ... min 1 200 400 600 800 1000 1200 1400 0 1 2 3 4 3 2 mm 6 4 mm Suction bar Pressure bar Figure 33 Sta Pure element 2 4 bar 30 60 psi 200 rpm counter clockwise rotation ml min 1 200 400 600 800 1000 1200 1400 1600 0 1 2 3 4 3 2 mm 6 4 mm Suction bar Pressure bar m 530pn en 09 02 02 22 151 ...

Страница 152: ...LoadSure Elements Counter clockwise Rotation 200 rpm RET rotor ml min 1 500 1000 1500 2000 2500 3000 3500 0 1 2 3 4 5 6 7 9 6 x 1 6mm 6 4 x 1 6mm 3 2 x 1 6mm Suction bar Pressure bar Note To achieve the discharge pressures stated above the rotor must be run counter clockwise To achieve optimal tube life run the rotor clockwise at a maximum discharge pressure of 2 bar 152 m 530pn en 09 02 02 22 ...

Страница 153: ... of W L Gore and Associates PROFINET is a registered trademark of PROFIBUS and PROFINET International PI Siemens is a registered trademark of Siemens AG SciLog and SciPres are registered trademarks of Parker Hannifin Corporation BioProTT is a trademark of em tec GmbH PendoTECH and PressureMAT are registered trademarks of PendoTECH FLEXMAG is a trademark of KROHNE Messtechnik GmbH SONOFLOW is a tra...

Страница 154: ... but Watson Marlow Fluid Technology Group accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING This product is not designed for use in and should not be used for patient connected applications 154 m 530pn en 09 02 02 22 ...

Страница 155: ...32 Publication history File Date of issue Notes m 530pn en 09 530 Pn PnN pump 01 22 First release m 530pn en 09 02 02 22 155 ...

Страница 156: ...tibility guide 93 Table 18 Maximum pump speed 108 Table 19 Sensor units 122 Table 20 Sensor pressure limits 124 Table 21 Sensor flow limits 124 Table 22 Error codes 133 Table 23 Drive spares 136 Table 24 General guide to cleaning with solvents 140 Table 25 1 6 mm wall tubing for 520R pumpheads 142 Table 26 2 4 mm wall tubing for 520R2 pumpheads 143 Table 27 2 4 mm wall elements for 520RE pumpheads...

Страница 157: ...m warning levels 125 Figure 24 Set slope adjust 128 Figure 25 Set offset adjust 130 Figure 26 Marprene continuous tubing 1 6 mm wall 200 rpm clockwise rotation 148 Figure 27 Marprene continuous tubing 1 6 mm wall 200 rpm counter clockwise rotation 148 Figure 28 Marprene continuous tubing 2 4 mm wall 200 rpm clockwise rotation 149 Figure 29 Marprene continuous tubing 2 4 mm wall 200 rpm counter clo...