FIREROD® Product Guide

 

WARNING – Risk of Electric Shock –

 The installation and wiring of this product shall only be done by    

 

a qualified electrician, in accordance with applicable national and local electrical codes. It is the end  

 

 

user’s responsibility to ensure that proper precautions are taken in reference to applicable personal  

 

 

safety equipment needed by those installing and maintaining equipment.

 

Never interrupt the protective earth circuit/ground. Any interruption or disconnection of the protective 

 

earth circuit used by this product will create a dangerous situation and could result in an electric shock    

 

that in some situations could lead to serious personal injury or property damage. It is the user’s  

 

responsibility to properly size the ground wire for the protective earth circuit/ground and to ensure  

 

that the impedance of such wire is low enough to avoid dangerous conditions.

 

In some equipment or installations a GFI style breaker or circuit should be installed to ensure the safe  

 

operation of the product. Determining if this is a requirement is the responsibility of the user.

 

The mains/line voltage applied to the product must always be equal to or less than the voltage rating  

 

 

marked on the product’s name plate/label. 

 

Some heaters are supplied as dual voltage (e.g. 240V / 480V) units and hence the user should check  

 

 

the wiring diagram to ensure that the product is wired correctly for its supply voltage. 

 

Thermostats should not be used as an “OFF” or disconnect device. The use of a disconnect switch or  

 

circuit breaker is highly recommended and will allow the isolation of the product when maintenance is  

 required

Minimum Circuit Requirements

 

WARNING – 

It is the user’s responsibility to properly size and install the feeder wires to the product.  

 

Feeder wire should be properly selected based on amperage, electrical power rating, ambient  

 

temperature, and type of environment.

 

It is the user’s responsibility to ensure that the bending radius of the products and/or any conductors/ 

 

cables and coverings (even if supplied by Watlow) are large enough to prevent any damage.

 

For components that do not already have insulated supply leads provided, user must take suitable  

 

action to either add suitable insulating sleeving or equivalent (with appropriate temperature and  

 

environmental rating) to suitably cover any exposed conductive surface.

4. Wiring

Minimum Recommended Circuit Requirements

Содержание FIREROD

Страница 1: ...product is properly selected and installed in accordance with applicable recommendations given within this guide Note this guide does not cover all foreseeable end use applications therefore consult y...

Страница 2: ...pre check During shipping and or storage the possibility of moisture absorption by the insulation material within a heater element is possible To determine if the proper megohm value is present use a...

Страница 3: ...ure control protection in systems where an over temperature fault condition could cause a fire or other hazard Failure to install temperature control protection where such a hazard exists could result...

Страница 4: ...mains line voltage applied to the product must always be equal to or less than the voltage rating marked on the product s name plate label Some heaters are supplied as dual voltage e g 240V 480V unit...

Страница 5: ...mm 5 8 in Fiberglass insulated 24 Ga MGT 300V 22 Ga MGT 300V 18 Ga MGT 300V 18 Ga MGT 600V PTFE insulated 24 Ga black PTFE 300V 22 Ga black PTFE 300V 18 Ga black PTFE 300V 14 Ga black PTFE 600V Minimu...

Страница 6: ...1 8 5 16 in 9 4 12 6 mm 3 8 and 7 16 in 12 6 15 8 mm 1 2 and 9 16 in 15 8 mm 5 8 in Recognition UL 1815 CSA UL 1659 CSA Max voltage 300 Volts 600 Volts Strands 7 32 7 30 7 26 19 27 Design description...

Страница 7: ...less than one megohm Refer to megohm pre check in the Installation section of this guide Not enough power application not heating to desired temperature Verify line voltage is within specification If...

Страница 8: ...may be found attached to any order acceptance or bid prepared by Watlow For a copy of such terms and conditions please contact Watlow s customer service department or visit our website http www watlow...

Отзывы: