FIREROD® Product Guide

3. Termination/Environment
  Do not handle the product by the lead wires or sensor wires!

  Handling by the leads can compromise electrical and/or mechanical integrity of the product. Certain wires such  

as fiberglass jacketed wires may also cause skin irritation or other personal injuries.

  In order to maintain termination integrity, the termination area should be kept below 400°F (222°C) or the  

maximum temperature rating of the lead wire insulation. Keep terminations clean, dry and tight. Do not allow oil, 
moisture or other possible contaminants to come in contact with the lead wires or the electrical termination end  
of the product.

 

CAUTION –  

Failure of components in a temperature control loop, such as the sensor, heater control relay  

 

or main temperature controller, can result in damage to a product in process, a product failure and/or  

 

damaging fire. To protect against this possibility, over-temperature protection must be provided to interrupt  

 

or remove power from the heater circuit during abnormal conditions. To limit this risk, perform a functional  

 

test of all temperature limiting devices on a regular interval.

 

CAUTION –  

Certain heating applications may accompany volumetric expansion and/or phase change. In all  

 

cases, ensure that appropriate safeguards against over-pressurization are included in system design. 

 

WARNING – 

Electric heaters are capable of developing high temperatures. To minimize the risk of fire or  

 

other personal injury or property damage, extreme care should be taken at all times to use and maintain   

 

the product in a safe environment. Operating this product in atmospheres containing combustible gases  

 

and vapors should be avoided. 

 

This product is not suitable for use in hazardous (classified) locations.

FIREROD® Product Guide

 

WARNING – 

Always install high temperature control protection in systems where an over temperature fault  

 

condition could cause a fire or other hazard. Failure to install temperature control protection where such a  

 

hazard exists could result in damage to equipment, property, and/or injury to personnel.

 

NOTE:

 It is the responsibility of the user to properly use overtemperature control devices or protection  

 

circuits, even if the product has been supplied with thermocouples or thermostats.

2.  Protection of heater elements from over temperature
 

The use of a temperature controller to regulate the heating process and prevent product over temperature is  
critical to ensure the safe operation. User shall also ensure that the thermal insulating materials used in the  
process do not come in contact with any portion of the product. It is the user’s responsibility to ensure safety  
of the installation.

 

CAUTION –  

Ensure that the heater is installed in the correct orientation. A hi limit sensor (if so equipped)  

 

is critical! For more information regarding the correct orientation for your product, contact your Watlow   

 

representative.  

 

For Immersion applications, in order to help prevent premature failure and a potentially hazardous  

 

condition in cases where consequences of failure may be severe, use an appropriate third party approved  

 

liquid level protection device. The liquid level should be such that the entire heater sheath (other than    

 

non-immersed cold section) is fully submerged with enough liquid above the heater to adequately dissipate  

 

heat from itself as under normal operating conditions

 

All temperature limit devices must have appropriate third-party approval and be applied in the classification for 
which it was tested and approved. The high temperature limiting device(s) should function independently from the 
process temperature control.

 

CAUTION –  

Heater orientation is important in order to ensure efficient heat transfer and safe operation.   

 

Care should be taken to allow enough room for heater expansion without compromising heat transfer. 

Содержание FIREROD

Страница 1: ...product is properly selected and installed in accordance with applicable recommendations given within this guide Note this guide does not cover all foreseeable end use applications therefore consult y...

Страница 2: ...pre check During shipping and or storage the possibility of moisture absorption by the insulation material within a heater element is possible To determine if the proper megohm value is present use a...

Страница 3: ...ure control protection in systems where an over temperature fault condition could cause a fire or other hazard Failure to install temperature control protection where such a hazard exists could result...

Страница 4: ...mains line voltage applied to the product must always be equal to or less than the voltage rating marked on the product s name plate label Some heaters are supplied as dual voltage e g 240V 480V unit...

Страница 5: ...mm 5 8 in Fiberglass insulated 24 Ga MGT 300V 22 Ga MGT 300V 18 Ga MGT 300V 18 Ga MGT 600V PTFE insulated 24 Ga black PTFE 300V 22 Ga black PTFE 300V 18 Ga black PTFE 300V 14 Ga black PTFE 600V Minimu...

Страница 6: ...1 8 5 16 in 9 4 12 6 mm 3 8 and 7 16 in 12 6 15 8 mm 1 2 and 9 16 in 15 8 mm 5 8 in Recognition UL 1815 CSA UL 1659 CSA Max voltage 300 Volts 600 Volts Strands 7 32 7 30 7 26 19 27 Design description...

Страница 7: ...less than one megohm Refer to megohm pre check in the Installation section of this guide Not enough power application not heating to desired temperature Verify line voltage is within specification If...

Страница 8: ...may be found attached to any order acceptance or bid prepared by Watlow For a copy of such terms and conditions please contact Watlow s customer service department or visit our website http www watlow...

Отзывы: