Watlow Controls 

EHG CL User’s Guide

Display

Parameter Name & Description

Range

Default

Modbus 
Relative 

Address

Data Type

& Read/

Write

[HyS]

[HyS]

On-Off Hysteresis

Set the how far below the set point 
the temperature can drop before the 
heater turns on.

3 to 28°C (5 to 50°F)

3°C (6°F)

41

unsigned 
integer

RWE

[`Pb]

[ Pb]

Proportional Band

Set the proportional band in tempera-
ture units.

0 to 68°C (0 to 122°F)

0°C or 0°F

37

signed in-
teger

RWE

[Int]

[Int]

Integral

Set the integral value in minutes per 
repeat.

0 to 999

0

38

signed in-
teger

RWE

[dEu]

[dEv]

Derivative

Set the derivative value in minutes.

0 to 999

0

39

signed in-
teger

RWE

[`Ct]

[ Ct]

Cycle Time

Set the cycle time in seconds.

5 to 60

10

40

unsigned 
integer

RWE

[Abt]

[Abt]

Ambient Temperature

View the ambient temperature.

0 to 106°C (0 to 190°F)

43°C (77°F)

24

unsigned 
integer

R

[Adr]

[Adr]

Modbus Device Address

View and or change the present Mod-
bus address.

1 to 247

1

15

unsigned 
integer

RWE

[bAU]

[bAU]

Modbus Baud Rate

Select the communication speed.

[`96]

 9,600 (15)

[192]

 19,200 (16)

[384]

 38,400 (17)

9,600

16

unsigned 
integer

RWE

[tU`]

[tU ]

Temperature Units

Select the temperature scale.

[``F]

 °F (4)

[``C]

 °C (5)

°C

17

unsigned 
integer

RWE

[rpp]

[rPP]

Restore Programmed Parameters

Restore factory default settings.

[yes]

 Yes

[`no]

 No

No

- - - -

- - - -

[bru]

[brv]

Base Release Version

View the controller’s base release 
version.

0 to 9999

- - - -

48

unsigned 
integer

R

[bPu]

[bPv]

Base Prototype Version

View the controller’s base prototype 
version.

0 to 9999

- - - -

49

unsigned 
integer

R

[bbu]

[bbu]

Base Build Version

View the controller’s base build num-
ber.

0 to 9999

- - - -

50

unsigned 
integer

R

[dru]

[drv]

Display Release Version

View the interface’s release version.

0 to 9999

- - - -

11

unsigned 
integer

R

[dPu]

[dPv]

Display Prototype Version

View the interface’s prototype ver-
sion.

0 to 9999

- - - -

12

unsigned 
integer

R

[dbu]

[dbv]

Display Build Version

View the interface’s build number.

0 to 9999

- - - -

13

unsigned 
integer

R

Note:

All values above 999 will be rounded off to fit in the three-character display. Full values can be  

read with other interfaces.

Note:

The EHG CL does not support Modbus function code 16 (0x10) Write Multiple Registers. Pa-
rameter values must be written individually with function code 6 (0x06) Write Single Registers.

R: Read
W: Write
E: EEPROM

Содержание EHG CLseries

Страница 1: ...erature controller and safety limit Process temperature output 10 amp NO ARC relay Safety limit 10 amp relay On off and PID temperature control algorithm Up graded via communications to PID algorithm...

Страница 2: ...to 0 C 32 F to SLA setting 150 C 302 F 34 unsigned integer RWE No Dis play Heat Output Power Read via Modbus communications the present heat output power level 0 to 100 0 22 unsigned integer R No Dis...

Страница 3: ...19 200 16 384 38 400 17 9 600 16 unsigned integer RWE tU tU Temperature Units Select the temperature scale F F 4 C C 5 C 17 unsigned integer RWE rpp rPP Restore Programmed Parameters Restore factory...

Страница 4: ...on on off off Ambient Alarm Abt 85 C on on off off Health Check Error Normal Operating Range Limit High Set Point SLA Closed Loop Set Point Closed Loop Set Point Temperature Alarm Hysteresis Alarm Hys...

Страница 5: ...1 507 494 5656 E12 CPU Clock Error Clock frequency is 5 MHz or 13 1 MHz Contact Technical Support at 1 507 494 5656 E13 Stack Over ow Stack has over owed Contact Technical Support at 1 507 494 5656 E1...

Страница 6: ...l is cleared when the process value is outside of the proportional band Integral Int is measured in minutes per repeat A low integral value causes a fast integrating action Proportional plus Integral...

Страница 7: ...r 4800 0021 With the control facing you this connector is on the right side L1 Switched black L2 white yellow red yellow red 1 3 4 5 7 8 6 2 Heater Limit Thermocouple Process Thermo couple Thermocoupl...

Страница 8: ...parts which upon examination prove to be defective within the warranty period specified This warranty does not apply to damage resulting from transportation alteration misuse or abuse WARNING To avoi...

Страница 9: ...nity EN 61000 4 4 2011 Electrical Fast Transient Burst Immunity EN 61000 4 5 2006 Surge Immunity EN 61000 4 6 2008 Conducted Immunity EN 61000 4 8 2009 Power frequency magnetic field immunity EN 61000...

Страница 10: ...ebsite www watlow co uk From outside The United Kingdom Tel 44 115 964 0777 Fax 44 115 964 0071 Asia and Paci c Watlow Singapore Pte Ltd 16 Ayer Rajah Crescent 06 03 04 Singapore 139965 Tel 65 6773 94...

Отзывы: