WATROD Circulation Heater Installation & Maintenance  Manual 

I&M NUMBER: 316-42-5-1 

 

Page: 3 

Date: 6/11/2008 

 

Rev: 2.00 

________________________________________________________________________________________________________________________________________________________________________________________________________________________

 

 

WATLOW IND.n  # 6 INDUSTRIAL LOOP RD. n HANNIBAL MO, 63401n PHONE 573-221-2816 n FAX 573-221-3723 

 

INLET

OUTLET

OUTLET

INLET

INLET

OUTLET

OUTLET

INLET

AIR / GAS APPLICATION

LIQUID APPLICATION

 

 

 

 

 

 

 

 

 

Figure # 1  

 

 

 

 

         Figure # 2  

 
 

NPSH

PUMP

NPSH

PUMP

INCORRECT HEATER POSITION - HEATER ABOVE NPSH

CORRECT HEATER POSITION - HEATER BELOW NPSH

 

Figure # 3  

 
 

When installing piping connections, care should be taken to avoid supporting the tank by the nozzles. 
Mounting blocks are provided to help prevent this. Provisions for thermal expansion and contraction 
should be considered, slotted bolt holes in one of the mating mounting pads would do adequately. 

 
 

Installation of an isolation valve and pressure relief valve is recommended but not provided. Rating of 
valves should not exceed the ANSI class 150 flange rating. Two 1/2" FNPT couplings are provided for 
drainage and installation of valves. 

 

  

 

DANGER: HAZARD OF FIRE.

 Electric heaters are capable of developing high temperatures so extreme 

care should be taken to locate heaters in safe environments. Mounting heaters in atmospheres 
containing combustible gases and vapors should be avoided. According to article 501 of the NEC, the 
maximum surface temperature of the heater shall not exceed 80 % of the auto-ignition of the surrounding 

Содержание WATROD 316-42-5-1

Страница 1: ...ibility of moisture absorption by the insulation material within the element is possible To ensure proper megohm values a minimum 500 VDC megohm meter Megger should be used to ensure that the megohm r...

Страница 2: ...from itself as under normal operating conditions Consult your local authorized sales representative for specific recommendations for your application 3 Terminal Enclosures Terminal enclosures should...

Страница 3: ...ions care should be taken to avoid supporting the tank by the nozzles Mounting blocks are provided to help prevent this Provisions for thermal expansion and contraction should be considered slotted bo...

Страница 4: ...le the bottom nut is supported Ground connection color coded green is supplied inside the housing for ground wire Line voltage must be equal to or less than rating stamped on the heater assembly Some...

Страница 5: ...rent if voltage is correct If line current is lower the heater may be wired wrong or has open elements Fluid not heating to desired Not enough Kw temperature Too much heat loss High limit tripping ala...