Electronics & Software
•
Software - GUI Control Panel
Watkiss DigiVAC Service Manual - Issue 2 - 29/11/04
93
7. After 40 to 60 seconds, the following prompt should appear:
Program success!
The process is now complete. You can reboot the DigiVAC by pressing
z
followed by return. Alternatively, switch the DigiVAC’s Mains On/Off
switch off and then on again. Hyperterminal can be closed, and the RS232
cable can be disconnected.
4.4.3.3 Updating Software from an SFM Card in Manual Mode
Once the RS232 connection is established (see Section 4.4.3.1), follow this
procedure to update the DigiVAC software from an SFM card in manual
mode.
Procedure
1. Insert the SFM Card in the slot on the CPU. Make sure the Card is inserted
squarely, and do not let go of it until you are sure it is located correctly in
the CPU. It is possible to drop the SFM Card inside the CPU’s casing if it
is inserted incorrectly.
2. To see what version of software is stored on the SFM Card, type
i
and
press return. The software version will be displayed in a table (see Figure
4:18).
Figure 4:18 Checking which Version of Software is Installed on the SFM Card.
3. To see what version of software is stored in the DigiVAC’s flash memory,
type
f
and press return.
4. In order to download the software from the SFM Card to the DigiVAC’s
download cache, type
l
and press return.
5. If the download is successful, you will see the following prompt:
Read SFM to download cache success.
This means that the software is currently stored in the DigiVAC’s down-
load cache.
Type
p
and press return to transfer the software to the flash memory. The
following prompt should now appear:
Program success!
The process is now complete. You can reboot the DigiVAC by typing
z
fol-
lowed by return. Alternatively, switch the DigiVAC’s Mains On/Off switch
off and then on again.
4.4.4 Installing Software Via an Ethernet Connection
The ethernet connection on the GUI CPU allows the DigiVAC to be linked di-
rectly to a computer network, or a stand-alone computer with an ethernet card.
In either case, the connection is made using a 10 Base T cable, which is widely
Software Version
Contents of SFM memory Module..
---- Download Header: ----
AppType: MPC82x DigiVAC
AppName: GUI Panel
AppBuildDate: Feb 16 2001 12:26:37
AppVersion: V0.2p
AppExeCompress: LZW Version 1.0
[WALBOOT]
Содержание DigiVAC
Страница 16: ...10 Watkiss DigiVAC Service Manual Issue 2 29 11 04 Overview Fuses...
Страница 136: ...130 Watkiss DigiVAC Service Manual Issue 2 29 11 04 Trouble Shooting...
Страница 140: ...134 Watkiss DigiVAC Service Manual Issue 2 29 11 04 Appendix...
Страница 141: ......