START UP PROCEDURE

1)  Check to see all connections are made

2)  Check that the pre-filter and pre-carbon sumps are secure with “O” rings in place using the 

housing wrench provided.

3)  Slowly turn on the water by turning the needle valve counterclockwise or ball valve 1/4 turn, 

where handle is parallel to the tubing line. 

4)  The valve handle on top of the tank should be in the open position, parallel to the valve 

body.

5)  The handle of the faucet should be in the closed position. 

6)  Check for leaks. 

7)  The Millennium

®

 drinking water system makes 2 gallons of drinking water per hour and 

requires 2 hours before water is readily available.

8)  During this initial fill period, you will hear water being discharged through the red drain 

line. This is normal as the contaminated water is being rejected by the reverse osmosis 

membrane.

The Millennium system comes with a manual flushing valve on the drain line. This must be 

closed during normal operation.
Remember to connect the transformer for the booster pump to a dedicated GFI electrical 

outlet.
CAUTION: ALWAYS CONSIDER ELECTRICAL SHOCK HAZARD WHEN WORKING WITH 

AND HANDLING ELECTRICAL EQUIPMENT. IF UNCERTAIN, CONSULT AN ELECTRICIAN. 

ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL 

AND STATE  ELECTRICAL CODES.
WARNING: DO NOT DRINK  WATER FROM THE FIRST TANK PRODUCED BY THE 

SYSTEM. COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET. 

DISCHARGING MIGHT TAKE UP TO 15 MIN.

If you have any difficulties with the installation, or require additional information on your unit please 

consult your local dealer.

We thank you for purchasing our Millennium

®

 Reverse Osmosis drinking water unit. In order 

to maintain high quality pure water, it is important that scheduled maintenance be followed.

RECOMMENDED MAINTENANCE

1)  Sediment Pre-filter: The Pre-Filter protects the system and should be maintained 

regularly. The Pre-Filter should be changed when the outside discolors to a cardboard 

brown color and before the inner core discolors. The life of the Pre-Filter will depend 

upon condition of your water supply and should be checked at 3 month intervals until 

a filter life is established (average life 6 months). Always make sure that o-rings are 

seated properly inside sumps before tightening canisters. 

2)  GAC & Carbon Block: Designed to remove chlorine from the water supply, as well as 

organic and inorganic substance before entering the TFC membrane (average life 12 

months). 

Always make sure that o-rings are seated properly inside sumps before tightening 

canisters. 

3)  Post-Carbon: The post-filter should be changed when you experience an unusual taste 

and/or odor to the water and has a nominal life of 1 year.

4)  Membrane: The high quality Thin Film Composite membrane should last between 2 to 4 

years depending on the quality of your local water & water usage.

Содержание new millenium

Страница 1: ...Installation Service Manual Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump...

Страница 2: ...Distributed by Serial...

Страница 3: ...ECTRICAL EQUIPMENT IF UNCERTAIN CONSULT AN ELECTRICIAN ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE ELECTRICAL CODES Before installing you will need to make sur...

Страница 4: ...line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball valve on...

Страница 5: ...er supply line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball...

Страница 6: ...t is used DC 38J Drain Clamp used for tapping into drainline for discharge of the wastewater down the drain when air gap faucet is used Teflon Tape 5 Teflon Tape Teflon Tape is used on all threaded fi...

Страница 7: ...the 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 PPASV121208W Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the PPASV...

Страница 8: ...en starting the hole Use a special porcelain hole cutter 4 For Stainless Steel Sink Before using the selected bit an indent should be made with a center punch to keep the drill bit from moving A small...

Страница 9: ...ket Drain line to air gap 1 4 red tubing Drain line from air gap to drain clamp 3 8 red tubing Darin Output Darin Input Chrome cover plate Plastic spacer Faucet connector 3 8 X 7 16 Faucet nut Metal w...

Страница 10: ...ig 7 5 Connect the 1 4 red tubing to the drain clamp or 3 8 when air gap faucet is used Sink Mount drain saddle at either location Never mount here DRAIN CLAMP INSTALLATION 1 The drain clamp assembly...

Страница 11: ...AP FAUCETS Connector White Plastic Sleeve Compression nut Plastic Tubing Brass Insert Fig 8 Fig 9 To disconnect ensure the system is depressurized before removing the tube Push in collet squarely agai...

Страница 12: ...HE FIRST TANK PRODUCED BY THE SYSTEM COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MIN If you have any difficulties with the installation or require a...

Страница 13: ...hould you require additional information or need further technical assistance on Millennium system contact your local dealer 5 Drain your storage tank frequently to ensure the freshness of the water i...

Страница 14: ...1 8 to turn with housing wrench DO NOT OVER TIGHTEN Over tightening will cause cracks and leaks if not careful CAUTION ALWAYS MAKE SURE THAT O RINGS ARE SEATED PROPERLY INSIDE SUMPS BEFORE TIGHTENING...

Страница 15: ...F WATER 2 BLADDER IN TANK IS RUPTURED TANK MUST BE REPLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP I...

Страница 16: ...o event shall Factory its subsidiaries or affiliates or their respective officers directors employees representatives dealers or agents be liable for special incidental consequential punitive indirect...

Отзывы: