9

POSITIONING THE SYSTEM

1)  The head assembly will stand up in the sink cabinet or can be hung on screws.
2)  The storage tank may be laid on its side. The bladder tank will function both  

ways horizontal and vertical.

3)  The head assembly and/or storage tank may be placed up to 10 feet from the point of use with some 

pressure loss.

CONNECTING THE SYSTEM

1)  Compression fitting may be found on the water supply adapter. To 

make the connections, slide a compression nut onto the tubing (Fig. 

8). Slip the white plastic sleeve onto the tubing with the beveled end 

towards the end of the tubing. Insert a brass or plastic insert into the 

tubing, bottom the tubing into the fitting, slide the nut up and tighten 

with a wrench. 

DO NOT OVER TIGHTEN. Do not use the brass 

sleeves on plastic tubing, use only plastic sleeves on plastic 

tubing.

2)  The plastic fitting on the drain clamp is connected by slipping the plastic 

nut onto the tubing. Bottom the tubing into the drain clamp and tighten 

firmly without tools. 

3-A)  See page 2 for connection diagram on color coded tubing on systems with STANDARD FAUCETS
3-B)  See page 3 for connection diagram on color coded tubing on systems with AIR GAP FAUCETS

Connector

White Plastic Sleeve

Compression nut 

Plastic Tubing

Brass Insert 

(Fig. 8)

(Fig.9)

To disconnect, ensure the system is depressurized before removing the tube.

 

Push in collet squarely against face of fitting. With the collet held in the 

 

position, the tube can be removed. The fitting can there be re-used.

Push in collet and remove tube

Disconnecting

Pull on the tube to check that it is secure. It is a good practice to test the

system prior to leaving site and/or before use.

4  Pull to check secure

Push the tube into the tube stop. The collet (gripper) has stainless steel

 

teeth which hold the tube firmly in position while the ‘O’ ring provides a

 

permanent leak proof seal.

3  Push up to tube stop

Fitting grips before it seals. Ensure tube is pushed into the tube stop.

2  Insert tube

Cut the tube square. It is essential that the outside diameter be free of score marks 

and that burrs and sharp edges be removed before inserting into fittings.  For soft 

thin walled plastic tubing, we recommend the use of a tube insert.

1  Cut tube into square

Push on collet

Pull on tubing

Pull on tubing

EZ FITTINGS- QUICK CONNECT

Your Millennium

 

reverse osmosis system is equipped with EZ fittings. The quick connect fittings feature leak 

proof installations. EZ Fittings provide efficient quick connection and disconnection resulting in reduction of 

service time and labor cost.

Содержание new millenium

Страница 1: ...Installation Service Manual Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump...

Страница 2: ...Distributed by Serial...

Страница 3: ...ECTRICAL EQUIPMENT IF UNCERTAIN CONSULT AN ELECTRICIAN ELECTRICAL WIRING SHOULD ONLY BE DONE BY A QUALIFIED ELECTRICIAN PER LOCAL AND STATE ELECTRICAL CODES Before installing you will need to make sur...

Страница 4: ...line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball valve on...

Страница 5: ...er supply line to inlet Feed ball valve labeled TO FEED 3 8 Blue Carbon post filter elbow labeled TO FAUCET to center threaded shank of faucet 3 8 Yellow Carbon post filter tee labeled TO TANK to ball...

Страница 6: ...t is used DC 38J Drain Clamp used for tapping into drainline for discharge of the wastewater down the drain when air gap faucet is used Teflon Tape 5 Teflon Tape Teflon Tape is used on all threaded fi...

Страница 7: ...the 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 PPASV121208W Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the PPASV...

Страница 8: ...en starting the hole Use a special porcelain hole cutter 4 For Stainless Steel Sink Before using the selected bit an indent should be made with a center punch to keep the drill bit from moving A small...

Страница 9: ...ket Drain line to air gap 1 4 red tubing Drain line from air gap to drain clamp 3 8 red tubing Darin Output Darin Input Chrome cover plate Plastic spacer Faucet connector 3 8 X 7 16 Faucet nut Metal w...

Страница 10: ...ig 7 5 Connect the 1 4 red tubing to the drain clamp or 3 8 when air gap faucet is used Sink Mount drain saddle at either location Never mount here DRAIN CLAMP INSTALLATION 1 The drain clamp assembly...

Страница 11: ...AP FAUCETS Connector White Plastic Sleeve Compression nut Plastic Tubing Brass Insert Fig 8 Fig 9 To disconnect ensure the system is depressurized before removing the tube Push in collet squarely agai...

Страница 12: ...HE FIRST TANK PRODUCED BY THE SYSTEM COMPLETELY DRAIN IT FROM THE STORAGE TANK BY OPENING THE FAUCET DISCHARGING MIGHT TAKE UP TO 15 MIN If you have any difficulties with the installation or require a...

Страница 13: ...hould you require additional information or need further technical assistance on Millennium system contact your local dealer 5 Drain your storage tank frequently to ensure the freshness of the water i...

Страница 14: ...1 8 to turn with housing wrench DO NOT OVER TIGHTEN Over tightening will cause cracks and leaks if not careful CAUTION ALWAYS MAKE SURE THAT O RINGS ARE SEATED PROPERLY INSIDE SUMPS BEFORE TIGHTENING...

Страница 15: ...F WATER 2 BLADDER IN TANK IS RUPTURED TANK MUST BE REPLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP I...

Страница 16: ...o event shall Factory its subsidiaries or affiliates or their respective officers directors employees representatives dealers or agents be liable for special incidental consequential punitive indirect...

Отзывы: