![Waterworld new millenium Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/waterworld/new-millenium/new-millenium_installation-and-service-manual_3685898011.webp)
9
POSITIONING THE SYSTEM
1) The head assembly will stand up in the sink cabinet or can be hung on screws.
2) The storage tank may be laid on its side. The bladder tank will function both
ways horizontal and vertical.
3) The head assembly and/or storage tank may be placed up to 10 feet from the point of use with some
pressure loss.
CONNECTING THE SYSTEM
1) Compression fitting may be found on the water supply adapter. To
make the connections, slide a compression nut onto the tubing (Fig.
8). Slip the white plastic sleeve onto the tubing with the beveled end
towards the end of the tubing. Insert a brass or plastic insert into the
tubing, bottom the tubing into the fitting, slide the nut up and tighten
with a wrench.
DO NOT OVER TIGHTEN. Do not use the brass
sleeves on plastic tubing, use only plastic sleeves on plastic
tubing.
2) The plastic fitting on the drain clamp is connected by slipping the plastic
nut onto the tubing. Bottom the tubing into the drain clamp and tighten
firmly without tools.
3-A) See page 2 for connection diagram on color coded tubing on systems with STANDARD FAUCETS
3-B) See page 3 for connection diagram on color coded tubing on systems with AIR GAP FAUCETS
Connector
White Plastic Sleeve
Compression nut
Plastic Tubing
Brass Insert
(Fig. 8)
(Fig.9)
To disconnect, ensure the system is depressurized before removing the tube.
Push in collet squarely against face of fitting. With the collet held in the
position, the tube can be removed. The fitting can there be re-used.
Push in collet and remove tube
Disconnecting
Pull on the tube to check that it is secure. It is a good practice to test the
system prior to leaving site and/or before use.
4 Pull to check secure
Push the tube into the tube stop. The collet (gripper) has stainless steel
teeth which hold the tube firmly in position while the ‘O’ ring provides a
permanent leak proof seal.
3 Push up to tube stop
Fitting grips before it seals. Ensure tube is pushed into the tube stop.
2 Insert tube
Cut the tube square. It is essential that the outside diameter be free of score marks
and that burrs and sharp edges be removed before inserting into fittings. For soft
thin walled plastic tubing, we recommend the use of a tube insert.
1 Cut tube into square
Push on collet
Pull on tubing
Pull on tubing
EZ FITTINGS- QUICK CONNECT
Your Millennium
reverse osmosis system is equipped with EZ fittings. The quick connect fittings feature leak
proof installations. EZ Fittings provide efficient quick connection and disconnection resulting in reduction of
service time and labor cost.
Содержание new millenium