• Display screen will not timeout for 1 minute
• If less than 100 events, end of the log will display a blank
• If more than 100 events, the newest event will overwrite the oldest event
• Events cannot be cleared unless the user reprograms the controller software.
n
SPA LIGHT:
this screen allows spa manufacturers to select the type of spa light that they install in the spa.
• There are 3 choices for spa light
· ON/OFF: light for normal standard spa lighting. Software just turns on or off the triac output.
· DIMMABLE: provides 5 levels of dimming for the light. Software will divide the 60Hz or 50Hz cycle to 5
different zones for minimum and maximum light intensities. Appropriate zone will turn on depending on the
dimming level the user selected.
· Color LED (for J&J color LED light): provides the user the ability to select a specific color every time they turn
on the light. A special software interface with J&J color box for color selection was implemented for the
ability to select specific color.
• DEFAULT setting for this option is set to ON/OFF light
• The SPA LIGHT setting set by the manufacturer will be saved in flash memory when the button is pressed and
remembered even if the system is powered off and on.
• This setting does not get reset by SYSTEM DEFAULT and can only be changed through this menu
n
CONFIGURATION PAGE SELECTION:
due to feature add-ons after implementing a communication protocol
that only has a maximum of 16 configurations. This screen is added to provide the ability to expand to many more
configurations in the future. Now the software can have up to 256 x 16 = 4096 configurations if needed. Currently
the configuration page is limited to 4 pages with a total of 64 configurations.
• The Spas Manufacturer will select a page number from 1 to 4 where their specific configuration for the spa is
located.
• The selected configuration page will save to the controller after the RETURN button pressed and remembered
even if the system is powered off and on.
· A new 16 configurations will be loaded to memory accordingly
· The current system configuration prior to the change configuration page is no longer valid. If the system is
powered off and on at this time, a wrong configuration may be loaded to the system.
· The user must go to configuration to select the desired configuration from the new configuration page
• DEFAULT setting for this option is set to page 1
• This setting does not get reset by SYSTEM DEFAULT and can only change through this menu
n
CONFIGURATION SELECTION:
allow spas manufacturers to select a specific configuration that matches with
their spas. To make the controller board a generic item for all manufacturers, the controller software only saves the
configuration page number, configuration number, and the configuration specific details like pump1 2 speed,
blower, light, etc. Panel software stores all available configurations. Spa manufacturers will set the configuration
that they want for their model through the panel and these will be saved to the controller.
• The Spa Manufacturer will select a configuration number from 1 to 16 where their specific configuration for the
spa is located.
• The selected configuration page will save to the controller after the RETURN button is pressed and remembered
even if the system is powered off and on.
· A system reboot will happened if the new configuration number and configuration details successfully send
down to the controller
· At controller power on, a new specific configuration detail and number will be sent from the controller to
the panel to tell the system how to configure and how the panel button functionality should be mapped
· The Panel will use the new configuration and button map layout as its software from now on