STEP FIVE
Look under your tub. The rails should be approximately 1/2” off the floor.
The space between the tub tom and floor must be completely filled with mortar and the mortar
HIGH LIMIT
covered with plastic sheet in step six.
The heater’s high-limit safety device will trip if the temperature exceeds a safe preset temperature. If the high-
limit trips, the heater will be disabled until the power has been removed from the heater and it has cooled. The
high-limit switch will automatically reset. This is most easily accomplished by turning off the circuit breaker
under the tub. Should the high-limit trip repeatedly, do not use the tub until the heater has been serviced.
OPTIONAL ELECTRIC IN LINE HEATER 120 volt 13.5 amp
Your whirlpool may be equipped with an electric heater to maintain
the water temperature lost through evaporation and convection loss.
The electric in-line heater will maintain the bath’s initial water
temperature and cycles with the pump.
ELECTRICAL REQUIREMENTS: (120 VOLT CLASS A GFI OUTLET (20 AMP)
STANDARD MOOD LIGHT OPERATION (120 VOLT CLASS A GFI OUTLET (20 AMP)
STEP SIX
To turn the mood light on press the round on/off button
Take the tub out of the cabinet and place enough mortar onto the floor in the area under the bottom
installed on your tub. To turn the mood light off press
of the tub to completely fill the space you saw in step five. This is usually 2” to 4”.
the button again. To change the bulb unscrew
Cover mortar with 3 to 5 mil plastic sheet to allow the tub to be removed in the future.
the central portion of the lens with the supplied tools
and carefully pull the lamp out. Take care not to disturb
NOTE:
the outer portion of the lens to prevent leaks.
The tub’s weight (including bather
To change the color of your mood light snap one of the colored filters over the clear lens.
And water) must be fully supported
by the mortar under the tub’s bottom-
LED MOOD LIGHT OPERATION (120 VOLT CLASS A GRI OUTLET (20 AMP)
not the tub lip that rests on
Pressing the LED button installed on your tub activates the LED lamp. Repeated pressing of the LED button
changes the color of the lamp in sequence until all the colors have been lit. Pressing the LED button again
causes the mood light to change colors in sequence until the LED button is pressed again turning the LED
mood light off.
cabinet tile.
OPTIONAL DEEP SOAK DRAIN AND OVERFLOW
The Deep Soak drain and overflow allows the overflow to be closed to
increase the water depth. Rotate overflow cover clockwise or counter
STEP SEVEN
clockwise to open or close the overflow. We suggest the overflow not be
Place the tub back in cabinet and push downward until tub lip rests evenly on top of cabinet,
closed until the bather is fully in the tub to insure the tub is not over filled..
the area between the tub bottom and the floor is filled completely, and the mortar squishes out
Watertech Whirlpool Baths assume no responsibility for damage
around the tub’s bottom.
caused by improper use of the Press Flow overflow.
OPTIONAL GRAB HANDLES
Grab handles are not designed to be mounted on the tub.
Mount your grab handles onto the tub cabinet or a surrounding wall.
Attach the handles with the supplied screws.
Mounting to drywall may require structural reinforcement.
AIR BATH BLOWER
All blowers are variable speed and turn on and off by pushing the control buttons on/off symbol.
To adjust the speed, repeatedly push the “-“ symbol to decrease speed or the “+” symbol
to increase speed.
The blower also has a drying/purge cycle that automatically activates 20 minutes after the
WARNING!
blower is turned off.
It is s normal for your blower to run automatically after it is turned off. The blower will
DO NOT GET INTO TUB FOR ANY REASON UNTIL
turn off at the end of the drying cycle.
MORTAR BED HAS CURED COMPLETELY AS YOUR TUB
ELECTRICAL REQUIREMENTS: 120 volt AC, 20 amp dedicated GFCI circuit.
COULD BE DAMAGED AND VOID OUR WARRANTY.
QUESTIONS?
PLEASE CALL
: 1-800-289-8827
FOR ASISTANCE
6
3