USER GUIDE

WHAT IS PINK SHOWER?

Pink Shower is a medical device for domes  c 
vaginal douches.

WHY USE PINK SHOWER

Pink Shower is used to remove residual blood 
inside the vagina a  er menstrual cycle, to 
perform a thorough cleaning or to so  en and 
expel excess vaginal secre  ons.
Pink Shower is recommended for proper 
vaginal hygiene, vagini  s, 

pre-post 

menopause syndrome.
It is always necessary to consult a doctor 
before using the device.

CONTRAINDICATIONS

Pink Shower must not be used in cases of:
post-opera  on and post menopause vaginal 
dryness, pregnancy; in health condi  ons 
that require special precau  ons, in some 
cases of skin hypersensi  vity caused by 
irrita  on, wounds, bruises, surgeries and/for 
other in

fl

 amma  ons. It is always necessary 

to consult your physician before using the 
device.

THE PACKAGE CONTAINS: 
• “Special Filter” pack containing:

 Special A  achment with internal thread (X)

 Special A  achment with external thread (Y)

  Aerator Filter (K)

 Gasket (W – with circular sec  on)  for 

Special A  achment with internal thread.

 Gasket (Z – with rectangular sec  on) for 

Special A  achment with external thread.

• Connector (B) with 80cm spiral tube (C) 
joint (D) and handle (F)
• 1,50 m. spiral tube extension (C2)
• Double 

fi

 lter membrane of 1,2 microns (E 

- Accessory).

• Bag containing n. 10 disposable vaginal 
cannulas (G) 

- length 11 cm - max. diameter 

of insertable part 7 mm

• Key for unscrewing 

fi

 lters (x2 – H)

• Universal Adaptor Addy (J)* with fastening 
key (J2)* – (Accessory)
• Pink Shower carrying bag
• Mul  lingual manual

** Only included in the “Travel” package.

FILTER ASSEMBLY*

To connect the Pink Shower aerator 

fi

 lter to 

the tap (bath sink, shower** or bath tub):
 1   -   Unscrew the aerator 

fi

 lter of your tap and 

make sure that the gasket is removed (

fi

 g 

1). If necessary, use the supplied key (H) - 

fi

 g. 1.1. In case of taps with a swivel mount 

fi

 lter (bidet type - 

fi

 g. 1.2) hold the upper 

part of the 

fi

 lter with one of the keys (H) 

and with the other key unscrew the lower 
part (the one to be replaced with Pink 
Shower Filter).

2a - In case of tap with internal thread (

fi

 g.2a), 

insert the aerator 

fi

 lter (K) inside the special 

a  achment the rectangular shaped gasket 
(Z) on the aerator 

fi

 lter (

fi

 g.2a). Screw then 

to the tap the 

fi

 lter with external thread 

(A1) just assembled (

fi

 g.3a).

2b - In case of tap with external thread 

(

fi

 g.2b), insert the circular shaped gasket 

(W) and the aerator 

fi

 lter (K) inside the 

special a  achment with internal thread (X) 
(

fi

 g.2b). Screw then to the tap the 

fi

 lter with 

internal thread (A2) just assembled (

fi

 g.3b).

3 - Screw the new Pink Shower 

fi

 lter with dry 

hands, using the connector (B) and turning 
an  -clockwise (

fi

 g.4). In case of taps with a 

swivel mount 

fi

 lter (bidet type), with a key 

(H) hold the upper part of the 

fi

 lter  and 

mount the Pink Shower 

fi

 lter supplied with 

connector.

Содержание pink SHOWER Basic

Страница 1: ...EN User guide www waterpowered eu customer waterpowered eu 800577477...

Страница 2: ...C2 F D H x2 2 J J2 X Y K W Z A2 A1 B C E op onal x10 General Pa ern G Included only in Travel version Special filter packet...

Страница 3: ...3 1 4 5 2a 3a 2b 1 1 3b 1 2 X Y K Z A1 A1 A2 A2 K W Filter assembly to the tap...

Страница 4: ...4 Addy Assembly From ref 6 to ref 14 only for Travel version for use at home see from ref 1 to ref 4 A en on for Basic version go to ref 15 6 9 7 8 OK NO OK NO min 16mm min 5mm max 25mm...

Страница 5: ...5 12 14 10 13 11 OK NO NO NO OK OK...

Страница 6: ...6 15 16a Use 17 16b Only for Travel version C2 D C...

Страница 7: ...7 19 21 22 18 20 Only for Travel version...

Страница 8: ...n 10 disposable vaginal cannulas G length 11 cm max diameter of insertable part 7 mm Key for unscrewing filters x2 H Universal Adaptor Addy J with fastening key J2 Accessory Pink Shower carrying bag...

Страница 9: ...n l the water flows from the valve located in the quick connector Ini ally for the first few moments there Theinstalla onofthefiltertothetapshould be done only the first me you connect Pink Shower the...

Страница 10: ...the filter tap 9 Unscrew the cannula from the handle could be some small leakage of water from the upper part of Addy but this will quickly stop If the leakage persists or becomes excessive it is reco...

Страница 11: ...ew the shower head F from the tube to drain the water dry thoroughly and place it into the Pink Shower WARNINGS Water Temperature it is best to use Pink Shower with warm water It is recommend however...

Страница 12: ...cute causata da irritazioni ferite escoriazioni in excess and blow on the side of the connector B to release residual water in the tube Fig 22 At the end screw the handle to the tube to preserve the...

Отзывы: