Waterous, Arizona Operations
Aquis 2.5 SSP Installation & Operation
Rev 3
Page 16 of 30
B. Flow Sensor
Cables: 3 meter (standard)
A molded cable is supplied, which
connects from the Flow sensor to the
Control box of the Pump / Motor
Driver Assembly.
The sensor has a built in temperature
sensor.
Note:
Extension cables can be daisy
chained to obtain longer
lengths.
Figure 6 Flow sensor
C. Cables
Making round coils of extra OIT and Flow sensor cables in the pump compartment can act as
an antenna. While the Flow sensor and OIT cables cannot be shortened, various lengths of
cable are available to minimize the "extra" cable in the truck.
When routing the cables, take care to avoid routing them next to antenna cables, radio power
lines and radio components. When there is extra cable, double the cable back on itself and
secure in a flat bundle with plastic wire ties instead of making a round coil.