INSTALLATION FOR
WALL MOUNT AUTOMATIC FAUCET
Rev. 2/20
P a g e
|
2
Diagram B
–
Parts Checklist
#
Description
Qty.
1
Spout Assembly
1
2
Spout Adapter
1
3
Solenoid Valve
1
4
Solenoid Bracket
1
5
Electrical Box
1
6
Solenoid Adapter
2
7
Battery
1
8
Wood Screw
4
9
Drywall Anchor
4
10 Wall Clip
5
Installation
1.
Flush the lines of all dirt and debris.
Note:
Failure to completely flush lines will cause valve failure and will void the warranty.
2.
Close water supply.
Note:
Refer to Diagrams A and B for Steps 3
–
4.
3.
Position
Electrical Box (5)
so the top is within 12” of the
desired spout position and secure with 2
Wood Screws (8)
.
Drywall Anchors (9)
may be used if securing to drywall.
4.
Position
Solenoid Bracket (4)
so the top of
Solenoid Valve (3)
is withing 28” of
the top of
Electrical
Box (5)
. Secure with 2
Wood Screws (8)
.
Drywall Anchors (9)
may be used if securing to drywall.
Note:
There must be access to
Electrical Box (5)
and
Solenoid Valve (3)
after the wall is closed and
installation is complete.
Note:
Refer to Diagrams B and C for Steps 5
–
8.
5.
Connect
Solenoid Adapters (6)
to
Solenoid Inlet (11)
and
Solenoid Outlet (12)
.
6.
Slide
Solenoid Valve (3)
into
Solenoid Bracket (4)
. Solenoid should be oriented with inlet on bottom
and outlet on right, as shown.
7.
Connect
Solenoid Wire (14)
to
Solenoid Wire Connector (13)
. Run
Sensor Wire (15)
to the spout
connection and connect to
Connecting Tab (17)
on
Spout Adapter (2).
8.
Route
Sensor Wire (15)
and
Solenoid Wire (14)
so they do not come in contact with each other, with
the piping or with any other metal.
Wall Clips (10)
may be used to assist with wire routing.
Diagram C
–
Sensor and Solenoid Adapter Connections
#
Description
2
Spout Adapter
3
Solenoid Valve
5
Electrical Box
6
Solenoid Adapter
11
Solenoid Inlet
12
Solenoid Outlet
13
Solenoid Wire Connector
14
Solenoid Wire
15
Sensor Wire
16
Red LED/White Button
17
Connecting Tab