background image

 

WL400 

Manual                                                                                                                                    Page 81 – Revision: 7‐16‐2018 

Overloads Tripped   
 

Overloads are a safety feature 
to ensure the tank does not 
overheat. 

Overloads will “click” when pushed.  The overload is automatically 
reset when pressed.   

 

 

See Resetting the Hot Tank Overloads or High Safety Limit 
Instructions that are included further below in this 
Troubleshooting Section

 

Thermostat or overloads 
“open” on Hot Tank 

Turn Power off.  Check OHM’s resistance across terminals on each 
Thermostat and Overloads separately. 

 

Good components will indicate a closed circuit or zero OHM’s on 
the meter. 

 

Replace components as necessary. 

Heating Coil not Working 

Turn Power off 

 

Drain hot tank 

 

Use multi‐meter to check heater element for approximately 26 
OHM’s resistance. 

 

Hot tank must be empty if you are checking for continuity.   

 

Replace Hot Tank as necessary. 

 
 

 

 