WL3 FX
Manual
Page 71 - Revision: 7-27-2022
6.
Low Flow of Water
–
Rated Service Flow: 1.9 L/min (0.5 gal/min)
Possible Reason
Solution
Determine Flow of Water
Rated Flow Rate is 1.89 Liters (0.5 gallons) per Minute. Check Flow
Rate by dispensing into a container for one minute. Measure the
amount of water that has been dispensed.
Feed Lines too small
Feed lines can restrict flow if run long distances from the supply. It
may be necessary to incr
ease the supply line (e.g. use 3/8” feed
line versus ¼”).
Elbows and turns in the line
Minimize elbows and turns in the feed line.
Filters
Filters with high pressure drop due to fouling or just by design.
Change filters more frequently or go to higher micron size filter for
local water conditions.
Restrictions
Flow path to ensure there are no undiscovered restrictions due to
debris or malfunctioning valves, including the supply valve at the
source.
Booster Pump
Add a booster pump to the supply line if the feed is slower than
needed.
7.
Hot Water Intermittently Forced Out through the Faucet, or a Dual Stream
out of the Faucet
Possible Reason
Solution
Mineral deposits on the
expansion slot inside the Hot
Tank vent chamber which
blocks the normal path of
water to expand.
Descale the Tank.
See Hot Tank Descaling Instructions that are included further
below win this Troubleshoot Section.
Содержание WL3 FX
Страница 32: ...WL3 FX Manual Page 32 Revision 7 27 2022 WL3 FX TOWER DRAWING AND PARTS LIST Wetted Parts Drawing...
Страница 46: ...WL3 FX Manual Page 46 Revision 7 27 2022 WL3 FX COUNTER TOP WATER FLOW DIAGRAM...
Страница 47: ...WL3 FX Manual Page 47 Revision 7 27 2022 WL3 FX TOWER WATER FLOW DIAGRAM...
Страница 50: ...WL3 FX Manual Page 50 Revision 7 27 2022 WL3 FX ELECTRICAL DIAGRAM SUPPLEMENT...