WL3 Technical Manual - Version 1, July 2014

22

23

Maintenance and Servicing

• Every six months it is strongly recommended that the UV lamp and filters be 

changed.

• The Firewall quartz spiral needs to be removed, inspected and cleaned where 

necessary.

• A WL3 Firewall with a hot water option may require any calcium build up in the 

hot tank to be removed, this depends on local water conditions

• No paperwork or cleaning records should be stored inside the WL3 Firewall.

1. 

You will need to stop the water supply to the machine by turning the isolation 

valve to the off position and releasing the pressure by depressing the cold water 

button until the water stops being dispensed.

2. 

Isolate the power to the WL3 Firewall by turning the red and green power 

switches off, these are located at the rear of the machine. Remove the power lead 

as a second safety precaution.

3. 

The filter is located in the WL3 Firewall base cabinet behind the lower front panel 

or within the top front panel if it is a mini model. 

4. 

To replace the filter detach the water pipes from the elbow fittings at the top, 

then the filter can then be removed from the retaining bracket. Unscrew the filter 

housing by twisting it clockwise, this will expose the carbon cartridge. The cartridge 

can then be removed from the filter housing and replaced.

5. 

The new filter will require flushing prior to being re-fitted in the WL3 Firewall. 

To do this connect a water feed directly into the inlet side of the filter and attach 

another length of pipe to the outlet side and direct this into a bucket/large container 

or drain, then flush through 10 litres of water to ensure that any loose carbon fines 

are fully removed from the filter to avoid any damage being caused to the machine.

6. 

After the filter has been flushed it can be replaced in the WL3 Firewall and the 

water pipes can be reconnected.

7. 

Remove the UV lamp by unplugging the UV loom connector and pulling the lamp 

upwards. Then undo the three screws and remove the top cover of the Firewall 

housing and the quartz spiral. 

8. 

Check the spiral for any scale build up and clean were necessary.

9. 

Examine the UV loom for any discolouration or wear, if there is any visible remove 

the loom and replace with a new one.

10. 

Replace the quartz spiral and reconnect and replace the UV lamp assembly and 

Firewall housing, making sure not to touch the new UV lamp with bare hands as this 

will shorten the life of the lamp.

11. 

Inspect all of the electrical and water connections on the machine, and take any 

action necessary to prevent a fault from occurring.

12. 

Check the faucet nipple for any calcium build up or any visible damage and 

clean or replace it if necessary.

13. 

Reassemble the machine and secure all panels with screws.

14. 

Check that the air gap around the machine is sufficient and there is nothing 

blocking the ventilation.

15. 

Reconnect the power to the machine and turn the red switch at the rear of the 

machine to the ‘on’ position.

16. 

Flush through 5 litres of hot and cold water and if there is the option, 5 litres of 

sparkling water to ensure the water is running clear of any carbon fines and that the 

taste of the water is clean and to the customers satisfaction. If you are not happy 

with the quality of the water continue to flush an additional 2-5 litre of water until 

you are satisfied with the taste.

17. 

The green heater and compressor switch can now be turned on, allow the 

machine to heat and cool the water.

18. 

Clean the outside of the machine with a non-abrasive anti-bacterial wipe or 

cloth.

19. 

Taste the water one final time and check it is cooling and heating the water.

SANITISING

You will need the following items:

• An empty Waterlogic inline filter housing 

• Rubber gloves

• Antibacterial wipes or spray

• Test strips

• A crosshead screwdriver

• Sanitisation fluid

• A container

1.  

Put on the rubber gloves to minimise the chance of any contamination to the 

machine and to protect yourself whilst the sanitisation procedure is being carried out.

2. 

Turn off the water supply to the machine and release the internal pressure by 

pushing the cold button until the cold water stops being dispensed. Then disconnect 

the water feed pipe from the bulkhead at the rear of the machine.

Содержание WL3 Firewall

Страница 1: ...WL3 Firewall Technical Manual...

Страница 2: ...ent not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses and by cli...

Страница 3: ...ore the Activated Carbon process will remove a whole range of contaminants e g chlorine and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achie...

Страница 4: ...ation tank at a minimum pressure of 3 2 bar This pressure is required to overcome the internal pressure from the CO2 gas which is in the tank IN FAUCET UV The Unique design allows the faucet area to b...

Страница 5: ...VALVE WATER IN SPARKLING WATER OUT SOLENOID VALVE PUMP CHECK VALVE CO2 In SPARKLING TANK SAFETY VALVE COLD SENSOR COLD TANK SUCK BACK SOLENOID VALVE CHECK VALVE HOT WATER OUT HOT WATER OUT AIR VENT S...

Страница 6: ...VALVE SOLENOID VALVE SPARKLING WATER OUT COLD SENSOR COLD TANK SOLENOID VALVE SUCK BACK SOLENOID VALVE CHECK VALVE AMBIENT WATER OUT COLD WATER OUT SOLENOID VALVE Wetted Parts Layout Cold Ambient and...

Страница 7: ...als could present a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used CO2 gas cylinders used for sparkling units are under h...

Страница 8: ...s required the whole way around the machine to allow for sufficient ventilation The WL3 must not be installed in direct sunlight adjacent to a heat source or in an ambient room where the temperature i...

Страница 9: ...he WL3 Firewall will then begin to cool and heat 12 The water temperatures are pre set at the factory to 5 c for the cold water and 87 c for the hot water 13 The water should now be taste tested any h...

Страница 10: ...ock 7 1 4 Pushfit Outlet Your WL3 is generally ready for use Dispensing your choice of water is very simple as follows 1 Place your cup centrally in the dispensing area 2 Select the type of water you...

Страница 11: ...he button starts flashing This means that the water is now heating to the extra hot temperature Once the button stops flashing press and hold the hot water button and simultaneously press the ambient...

Страница 12: ...Firewall housing and the quartz spiral 8 Check the spiral for any scale build up and clean were necessary 9 Examine the UV loom for any discolouration or wear if there is any visible remove the loom a...

Страница 13: ...removing the UV lamp Inspect the spiral for any damage or calcium build up if there is a large amount of calcium remove and replace the spiral and send it away to be treated by an ultrasonic bath 11 U...

Страница 14: ...re to the WL3 Firewall is 45 PSI Check the filters are not partially blocked that the solenoid valves function correctly hot tank calcium build up need to be de scaled cold tank ice build up needs to...

Страница 15: ...FS CAS WL3 M HCA WL3 M CA WL3 M CAS Machine Size 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 365mm D x 1140mm H 385mm W x 460mm D x 486mm H 385mm...

Страница 16: ...o the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the grow...

Страница 17: ...id Valve DC24V 1000mm 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 PI0308S 15 1 4 PE Pipe 16 Water Pressure Pump DC24 Daehwa 17 1 4 PE Pipe 18 JG Equal Elbow Connector 1 4 PI0308S 19...

Страница 18: ...Elbow Connector 1 4 PI0308S 36 Solenoid Valve DC24V 1000mm 37 1 4 PE Pipe 38 1 4 PE Pipe 39 1 4 PE Pipe 40 JG Equal Elbow Connector 1 4 PI0308S 41 JG Equal Tee Connector 1 4 42 FW Assm 43 JG Equal El...

Страница 19: ...ite WL650 universal as ST 8011 16 JG Equal Elbow Connector 1 4 PI0308S 17 Solenoid Valve DC24V 1000mm 18 JG Equal Elbow Connector 1 4 PI0308S 19 JG Equal Elbow Connector 1 4 PI0308S 20 Solenoid Valve...

Страница 20: ...ual Elbow Connector 1 4 PI0308S 68 JG Equal Straight Connector 1 4 69 Wire Condenser WL650FS 70 13W UV Lamp UV and wire and plastic connector assembled N Part Description 31 Universal FS Filter Bracke...

Страница 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Canada and Mexico info waterlogicusa com 1 402 884 72...

Отзывы: