INSTALLATION KIT
The WL3 Firewall must be installed according to the local guidelines and a pressure
reducer must be installed as part of the installation. The pressure reducer should
not be set higher than 3bar.
• The WL3 Firewall should not be connected to water supplies of unknown bacterial
quality or those not already fit for human consumption. The WL3 Firewall should
only be connected to a Potable drinking water supply.
• The filter on the WL3 Firewall must be changed every 6 months.
• The UV lamp on the WL3 Firewall must be changed every 6 months.
• The cold tank should also be flushed and sanitised every 6 months.
• Waterlogic International strongly recommends the use of an anti-flood device.
• Figure 1 is the recommended installation kit.
The part number for the installation kit shown below is “P-KIT-INSTALLATION”
Fig 1. Waterlogic
Installation Kit
1 - 15mm Compression Inlet
2 - Double Check Valve (great for carbonated water)
3 - Adjustable Pressure Reducing Valve
4 - Integral Isolator
5 - Pressure Gauge Port
6 - Waterblock
7 - 1/4” Pushfit Outlet
Your WL3 is generally ready for use.
DISPENSING yOUR CHOICE OF WATER IS VERy SIMPLE,
AS FOLLOWS:
1
. Place your cup centrally in the dispensing area
2
. Select the type of water you wish to be dispensed and press/touch the
corresponding button.
3
. Keep the button depressed until your cup has reached the desired level, and then
release the button.
SLEEP MODE
Some WL3 models have a sleep mode function for the hot water tank. This is an
energy saving feature to reduce the amount of power consumed by the machine.
The machine will enter sleep mode after three hours and can be brought back out
of the sleep mode by selecting any of the buttons on the front panel. If you wish to
deactivate the machine’s sleep mode, please follow the instructions below using
dip switch 3 on the machine’s main PCB.
Operating Instructions
HOT WATER CAUTION
• Always place cup / mug in the centre of the drip tray.
• Always use a ceramic cup or a cup suitable for use with
hot water.
• Do not hold cup or place hands in dispensing area
whilst dispensing water.
• Do not dispense water in a stop start style of vending
• (Hold the button continuously until cup is full).
• Never try to fill more than one vessel at a time.
1
2
6
4
7
3
5
Hot tank sleep mode off
Hot tank sleep mode on