manualshive.com logo in svg
background image

2

3

Waterlogic 2 Firewall Technical Manual - Issue B, May 2014

Declaration

Waterlogic International Ltd

1.

 The installation, maintenance and sanitizing procedures must be carried out by persons trained by 

Waterlogic International or their approved distributors. Do not remove any panels or covers unless 
acceptable in this instruction.

2. 

When any abnormal case happens, firstly unplug the appliance.

3. 

This appliance is not intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the use of the appliance by a person responsible for their safety.   

4. 

Children should be supervised to ensure that they do not play with the appliance. 

5. 

This appliance can be used by children aged from 8 years and above if they have been given 

supervision or instruction concerning use of the appliance in a safe way and if they understand the 
hazards involved. Cleaning and user maintenance shall not be made by children unless they are older 
than 8 and supervised. Keep the appliance and its power cord out of reach of children aged less than 
8 years. 

6. 

Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge if they have been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved.  

7. 

Children must not play with the appliance. 

8. 

If the supply cord or the detachable cord sets are damaged, it must be replaced by the manufacturer, 

its service agent or a similarly qualified person in order to avoid a hazard.

9. 

The detachable hose-sets and the connection kit used to connect the main water are supplied by 

the technician. Don’t reuse the old ones. 

10. 

The appliance is to be supplied through a residual current device (RCD) having a rated residual 

operating current not exceeding 30mA.

11. 

This appliance is intended to be used in household and similar applications such as 

 

- staff kitchen areas in shops, offices and other working environments; 

 

- farm houses and by clients in hotels, motels and other residential type environments; 

 

- bed and breakfast type environments; 

 

- catering and similar non-retail applications.

12. 

This appliance contains a UV-C emitter (UV lamp)

13. 

Unintended use of the appliance or damage to the housing may result in the escape of dangerous 

UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. 

14. 

Appliances that are obviously damaged must not be used. 

15. 

The replacement of the UV lamp must be carried out by personnel trained by Waterlogic International 

or their approved distributors. 

16. 

Read the maintenance instructions before opening the appliance.

17. 

The appliance must be disconnected from the power supply before replacing the UV lamp.    

18. 

The UV lamp must be replaced at 6 month intervals or when necessary. If the unit is placed 

in a high use area, the UV lamp will need to be replaced more frequently. 
The quartz spiral can be cleaned by using an ultrasonic bath if needed.

19. WARNING:

 Do not operate the UV lamp when it is removed from the appliance enclosure.

Index

Technical Manual

Welcome to your new Waterlogic machine.  
This Technical Manual is to help you get great tasting water cup 
after cup by making the most of the product’s features.

Machine Overview 

 4

Mains Parts Layout - Cold only

 8

Mains Parts Layout - Cold and ambient

 9

Main Parts Layout - Hot and Cold

10

Pre Delivery Inspection Procedures (PDI)

11

Installation Procedures

13

Operating Instructions

16

Maintenance and Servicing

18

Sanitising

19

De-scaling

20

Technical Specifications and Warranties

22

End of Life

24

ROHS

24

BioCote®

24

Electrical Wiring Diagram 230V - Cold Only

26

Electrical Wiring Diagram 230V - Cold and Ambient 

27

Electrical Wiring Diagram 230V - Hot and Cold

28

Wetted Parts Illustration - Wetted Parts List

30

Main Parts List Illustration - Freestanding model

32

Main Parts List Illustration - Mini model

36

Содержание WL2 Firewall

Страница 1: ...Waterlogic 2 Firewall Technical Manual Issue B May 2014 WL2 Firewall Technical Manual...

Страница 2: ...l operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm h...

Страница 3: ...rmister and it is pre set at the factory at approximately 87 C A BI metal overload thermostat is fitted to stop the tank overheating and can be reset manually Setting the hot water temperature at 87 C...

Страница 4: ...irect sunlight Placing the WL2 Firewall in direct sunlight from a window close to a radiator or in a room of high ambient temperature will affect the efficiency of the refrigeration circuit FIREWALL C...

Страница 5: ...Wetted Parts Layout Cold and Ambient FILTER IN Water SOLENOID VALVE SOLENOID VALVE COLD WATER OUT FILTER DRYER COLD SENSOR COLD TANK COMPRESSOR CONDENSER FILTER IN Water SOLENOID VALVE COLD WATER OUT...

Страница 6: ...Flush water approximately 10 litres through the hot tank first until the water runs clear of any carbon fines 7 Now flush water through the cold tank with approximately 10 litres of water 8 Once you a...

Страница 7: ...to the machine Minimum operating pres sure for the machine to work suitably is 2 5 bar The ideal operating pressure is at 3 bar At pressures higher than 3 bar the machine will not function correctly...

Страница 8: ...ou use an accurate pre viously calibrated thermometer 16 Please ensure that the cold water produced has a good taste If you detect a plastic taste then it is an indication that the machine needs to be...

Страница 9: ...the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not dispense water in a stop...

Страница 10: ...e The new filter can now be installed into the machine 6 Remove the UV lamp by unplugging the UV lamp connector and pulling the lamp upwards 7 Check the quartz spiral for scale build up and clean if n...

Страница 11: ...grill DE SCALING Items needed to carry out the de scaling procedure Rubber gloves A container that can hold 5 liters A funnel or syringe A Phillips Cross head screwdriver De scale solution Non abrasi...

Страница 12: ...tions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of constant and continual improvement and therefore...

Страница 13: ...s silver technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory...

Страница 14: ...26 27 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Cold and Ambient 230V Models Main PCB Schematic Diagram Cold only 230V Models...

Страница 15: ...28 29 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Hot and Cold 230V Models...

Страница 16: ...Valve DC24V 1000mm 8 JG Equal Elbow Connector 1 4 9 JG LLD PE Tube Blue O D 1 4 10 JG Equal Elbow Connector 1 4 11 Cold Tank Assembly 4 Liters No UV Holder 12 JG Equal Elbow Connector 1 4 13 JG LLD P...

Страница 17: ...15 JG Equal Elbow Connector 1 4 16 Solenoid Valve DC24V 1000mm 17 JG Equal Tee Connector 1 4 18 Solenoid Valve DC24V 1000mm 19 JG Equal Elbow Connector 1 4 20 Cushion for Solenoid Valve 21 Filter Bra...

Страница 18: ...r 39 Firewall Display PCB Universal H C C A CO 40 Silicon Button Key Mat CA 41 Firewall Front Upper Insert Panel 42 Button Label HC CA 43 Drip Tray Grill 44 Drip Tray Body Charcoal 45 Firewall Hot Wat...

Страница 19: ...r Fuse 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel Left 9 JG Bulkhead Connector Union 1 4 1 4 10 Plastic Cap for 1 4 Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt...

Страница 20: ...lver Front Panel for Drip Tray insert Firewall 37 Firewall PCB Cover 38 Firewall Display PCB Universal H C C A CO 39 Silicon Button Key Mat CA N Part Description 40 Front upper insert panel 41 Button...

Страница 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...

Отзывы: