WL100

 Manual                                                                     Page 48                                                                      Revision: 1‐14‐2019 

 

2.

 

Red Power Switch is lit but the Red LED on the Front is not lit  

 
 

Possible Reason 

Solution 

Bad Transformer 

Replace Transformer 

Black Power Connector to the 
PCB is not properly connected 

Properly connect. 

Bad Front PCB  

Replace Front PCB 

Part Number EN‐6130 – WLCP PN 20‐0040 

Bad Energy Saver PCB 

Replace Energy Saver PCB 

Part Number EN‐6131 – WLCP PN 20‐0075 

Defective Red Heater / 
Compressor Switch 

Replace Red Heater / Compressor Switch 

 

3.

 

Compressor Runs But Does Not Chill 

 
 

Possible Reason 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow into unit. 

Make sure unit is not under minimum ventilation requirements (2 
to 4 inches). 

Compressor is running very 
hot. 

Low or lost refrigerant.  Refrigerant recharge required. 

 

 

 