background image

 

WL100

 Manual                                                                     Page 39                                                                      Revision: 1‐14‐2019 

8.

 

Once flushed, install the filters.  Following the flow direction on the filter. 

 

NOTE:

  

Filters should not be flushed prior to 24 hours before installation to limit Microbial 

Growth.   
 

9.

 

Connect 

WL100 Water Treatment System 

to power.  

 

       CAUTION!  

NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 

 

Red Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the overload (high 
limit) will require manual reset if Heater is turned on with an empty Hot Tank.  

 

 

Flushing the Sanitizer from the Machine 
 

10.

 

Place a pitcher, catch basin, or other container under the faucet of the 

WL100 Water Treatment 

System

.     

 

11.

 

Flush the Cold Tank.  Run several gallons of water through the faucet by dispensing cold water to 
dilute and remove the sanitizer from the cold circuit.  Chlorine test strips can be used to evaluate 
the water.  

 

12.

 

Once the sanitizer odor/taste has been flushed out of the cold side of the machine the 
sanitization process for the Cold Circuit is now complete.    

 

Fill the Hot Tank 
 

13.

 

Press the Hot Water Select Button, followed by the Main Dispensing Button to fill the Hot Tank.  
Water will dispense from the faucet once the Hot Tank is full.  Flush until water is clear. 
 

      

WARNING!  

HOT CIRCUIT IS NOT SANITIZED.   

Water in the Hot Circuit is not sanitary until the temperature exceeds 77°C (171°F) for at least 
5 minutes. 

 

Compressor Test 
 

14.

 

Switch Red Compressor / Heater to on 

I=ON position

.  Always ensure Tanks are 

full of water before turning on the Heater or the Overload (High Limit) opens and 
require manual reset.  If the Wire Condenser at back of the 

WL100 Water 

Treatment System

 is warm, the refrigeration system is working.    

 

 

15.

 

Once the machine reaches its target temperature, the Compressor will shut off.  Draw a glass of 
cold water and verify it has chilled to proper temperature. 

 

Содержание WL100

Страница 1: ...rain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Ma...

Страница 2: ...ainer and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 8 or 11 Liters 2 or 3 gallons of water...

Страница 3: ...he cold circuit Chlorine test strips can be used to evaluate the water 12 Once the sanitizer odor taste has been flushed out of the cold side of the machine the sanitization process for the Cold Circu...

Страница 4: ...e the Heater approximately 10 minutes to heat the water from ambient 24 C 75 F to the factory set point of 85 C 185 F Dispense a cup of hot water to ensure the temperature odor taste is acceptable WAR...

Страница 5: ...ncoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc from scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor...

Страница 6: ...ont Panel 8 Unclip the White Red and Black wire connectors from PCB to allow Front Cover to be removed 9 Remove Front Panel 10 Disconnect tubing to allow water to drain from the WL100 Water Treatment...

Страница 7: ...ater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Red Compressor Heater Switch mus...

Страница 8: ...e Solenoids 7 Disconnect tank line outlet lines from Hot and Cold Solenoids to drain into basin or bucket 8 Turn outlet fittings outward to avoid water spilling onto the Compressor 9 Reconnect Tubing...

Страница 9: ...on CAUTION USE A WATER PRESSURE REGULATOR Waterlogic will not be responsible for injury or damage caused by excessive water pressure Operating pressure must be 40 psi to 60 psi Be aware any of potenti...

Страница 10: ...must be in the O OFF position while the Hot Tank is empty Damage could occur within one minute and the overload high limit will require manual reset if Heater is turned on with an empty Hot Tank 6 Mo...

Отзывы: