SAFETY ALERT SYMBOLS 

 

Read and follow all safety information carefully.  The signal words used in this manual are selected as 
shown below and based on an assessment of the degree of potential injury or damage (severe or 
minor) and the occurrence of injury (definitely occurs or has the potential to occur) when the 
warning is ignored: 

 

 DANGER!   

Indicates a situation which, when not avoided, results in death or severe injury.   

 

 WARNING!   

Indicates a situation which, when not avoided, has the potential to result in death or severe 
injury; and/or severe property damage.  

  

 

 CAUTION!   

Indicates a situation which, when not avoided, results or has the potential to result in minor 
injury; and/or minor property damage. 

 

 

SAFETY PRECAUTIONS 

 

Basic safety precautions should be followed, including the following: 

Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met 
when installing 

Waterlogic

 Equipment.   Only qualified service technicians should attempt 

installation and service of 

Waterlogic

 Equipment.  Always read the entire operating instructions 

before using the appliance and save these instructions for future use. 

 

DANGER!  

This product can cause death or severe injury if incorrectly operated, installed or 

maintained. 

The installation, maintenance, sanitizing and any repair must be performed by 

qualified persons trained by Waterlogic International or their approved distributors only.  Do not 
remove any panel or cover to protect against electrical shock and exposure to UV radiation.   

 

 

DANGER! 

ELECTRICAL SHOCK HAZARD

.  

Always use a dedicated and properly grounded outlet.  

Unit should be protected by ground‐fault circuit interrupter (GFCI) or residual current device (RCD) 
having a rated residual operating current not exceeding 30mA.  Use only Waterlogic supplied 
power cord. Never use extension cords or power strips to connect unit. Do not use if the power 
supply cord is damaged. Always unplug from power supply prior to servicing. 

 

 

WARNING!

  

AUTHORIZED USE ONLY.  

This appliance is to be used for its intended purpose as 

described in this manual and untrained individuals who use this manual assume the risk of any 
resulting property damage or personal injury.  This appliance can’t be used by children and persons 
with reduced physical, sensory or mental capabilities or lack of experience.   

 

WARNING!

  

DO NOT OPERATE IF DAMAGED.

  Unplug and isolate water supply if abnormal 

conditions exist. Contact Waterlogic or authorized dealer for repair, service, and installation to 
avoid hazards.  

 

WARNING! 

CONNECT TO POTABLE WATER SUPPLY.

  This system is to be used for water only and is 

not intended for use where water is microbiologically unsafe or with water of unknown quality 
without adequate disinfection before or after the system. 

 

 

Содержание BLUPURA FIZZ 80

Страница 1: ...installation maintenance sanitizing and any repair must be performed by qualified persons trained by Waterlogic International or their approved distributors only Do not remove any panel or cover to p...

Страница 2: ...eratures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around the unit Minimum clearance aroun...

Страница 3: ...he BLUPURA FIZZ 80 Water Treatment System supply head brings contemporary style and state of the art technology to commercial water dispensers combining professional performance with a modern sleek de...

Страница 4: ...on 3 8 Inlet Water Pipe Recommended Service Pressure 14 5 51 psi 10 MPa 0 35 MPa Use Pressure Regulator specification label on back of machine states 51 58 psi which one is correct Incoming Flow Rate...

Страница 5: ...360 x 566 x 570 mm 14 2 x 22 3 x 22 4 Inches 420 x 590 x 720 mm 16 5 x 23 2 x 28 3 inches Weight dry 27 kg 59 pounds 30 kg 66 pounds ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 1PH 15 Amp Se...

Страница 6: ...RUCTIONS For Cold Sparkling Water Pull Tap Knob forward to start dispensing Push Tab Knob back to stop dispensing For Cold Water Pull Tap Knob forward to start dispensing Push Tab Knob back to stop di...

Страница 7: ...WING PRODUCTS Using the following product can cause surface pitting oxidization and give the impression that the surface of the product is rusting Full strength bleach Only use bleach diluted 1 part b...

Страница 8: ...BLUPURA Fizz 80 Manual Page 11 Revision 11 2 2018 WEEKLY MAINTENANCE REQUIRED BY CUSTOMER 1 Use a vacuum to clean out all vents...

Страница 9: ...rlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installatio...

Отзывы: