background image

Electrical work 

2005/06/10 

37 / 60 

 

Copyright 

 2013 by: WATERKOTTE GmbH. Subject to changes. 

 

8.4.4 

Controller WWPR 2 

 

 

 

Deutsch 

Englisch 

Französisch 

U1 

–    Verdampfungsdruck 

U1 

–    Evaporation pressure 

U1 

–    Pression evaporation 

U2 

–    Temp. Sauggas 

U2 

–    Temp. suction gas 

U2 

–    Temp. gaz aspires 

U3 

–    Kondensationsdruck 

U3 

–    Condensation pressure 

U3 

–    Pression condensation 

U4 

–    Temp. Quelle Ein 

U4 

–    Temp. source entrance 

U4 

–    Temp. entrée captage 

U5 

–    Temp. Quelle Aus 

U5 

–    Temp. source exit 

U5 

–    Temp. sortie captage 

U6 

–    Temp. Außen / 0-10V  Heizen 

U6 

–    Temp. outdoor / 0-10V        

heating 

U6 

–    Temp. exter / 0-10V chauffage 

U7 

–    Temp. Raum / 0-10V Kühlen 

U7 

–    Temp. room / 0-10V cooling 

U7 

–    Temp. pièce / 0-10V rafraîchis-

sement 

U8 

–    Temp. Vorlauf 

U8 

–    Temp. flow 

U8 

–    Temp. départ chauffage 

U9 

–    Temp. Rücklauf 

U9 

–    Temp. return 

U9 

–    Temp. retour chauffage 

U10 

–  Temp. Speicher 

U10 

–  Temp. buffer 

U10 

–  Temp. ballon tampon 

U11 

–  Temp. Warmwasser 

U11 

–  Temp. hot water 

U11 

–  Temp. ECS 

U12 

–  Phase / Drehfeld 

U12 

–  Phase / Rotary field 

U12 

–  Panne phase 

J9 

–     Erweiterungsbus 

J9 

–     Extension bus 

J9 

–     Bus d‘extension 

J12 

–    EVD1 

J12 

–    EVD1 

J12 

–    EVD1 

J14 

–    Touch Display 

J14 

–    Touch Display 

J14 

–    Touch Display 

J15 

–    pgD1-Display 

J15 

–    pgD1-Display 

J15 

–    pgD1-Display 

Y1 

–     Pumpe Quelle 

Y1 

–     Pump source 

Y1 

–     Pompe captage 

Y2 

–     Pumpe Heizung 

Y2 

–     Pump heating 

Y2 

–     Pompe chauffage 

Y3 

–     Pumpe Warmwasser 

Y3 

–     Pump hot water 

Y3 

–     Pompe ECS 

Y4 

–     Kompressor 1 

Y4 

–     Compressor 1 

Y4 

–     Compresseur 1 

Y5 

–     Kompressor 2 

Y5 

–     Compressor 2 

Y5 

–     Compresseur 2 

Di1 

–    Störmeldung Quelle 

Di1 

–    Failure message source 

Di1 

–    Message de panne captage 

Di2 

–    Störmeldung Heizung 

Di2 

–    Failure message heating 

Di2 

–    Message de panne chauffage 

Di3 

–    SG-Ready-A / EVU 

Di3 

–    SG-Ready-A / EVU 

Di3 

–    SG-Ready-A / Coupure ex-

terne 

Di4 

–    SG-Ready-B / Sollwertbeein-

flussung 

Di4 

–    SG-Ready-B / Setpoint influ-

ence 

Di4 

–    SG-Ready-B / Valeur consigne 

Di7 

–    HD-Schalter 

Di7 

–    HP-Switch 

Di7 

–    Interrupteur HP 

Di8 

–    ND-Schalter 

Di8 

–    LP-Switch 

Di8 

–    Interrupteur BP 

Di9 

–    MS1 

Di9 

–    Motor protection MS1 

Di9 

–    Protection moteur MS1 

Di10 

–  MS2 

Di10 

–  Motor protection MS2 

Di10 

–  Protection moteur MS2 

NO1 

–  

NO1 

–  

NO1 

–  

NC1 

–  

NC1 

–  

NC1 

–  

Out2 

–  Ext. Wärmeerzeuger 

Out2 

–  Ext. heat generator 

Out2 

–  Producter de chaleur ext. 

Out3 

–  Kompressor 1 

Out3 

–  Compressor 1 

Out3 

–  Compresseur 1 

Out4 

–  Kompressor 2 

Out4 

–  Compressor 2 

Out4 

–  Compresseur 2 

Out5 

–  4-Wege-Ventil 

Out5 

–  4-way-valve 

Out5 

–  Vanne-4-voies 

NO6 

–   Pumpe Quelle 

NO6 

–   Pump source 

NO6 

–   Pompe captage 

NO7 

–   Pumpe Heizung 

NO7 

–   Pump heating 

NO7 

–   Pompe chauffage 

NO8 

–   Speicherentladepumpe 

NO8 

–   Buffer unloading pump 

NO8 

–   Pompe décharge ballon 

NO9 

–   MKV Hzg/WW => WW 

NO9 

–   MBV Htg/HW => HW 

NO9 

–   Vanne Ch/ECS => ECS 

NC9 

–   MKV Hzg/WW => Hzg 

NC9 

–   MBV Htg/HW => Htg 

NC9 

–   Vanne Ch/ECS => Ch 

NO10 

– MKV Hzg/Klg => Klg 

NO10 

–  MBV Htg/Cool => Cool 

NO10 

– Vanne Ch/Rafr => Rafr 

NC10 

– MKV Hzg/Klg => Hzg 

NC10 

– MBV Htg/Cool => Htg 

NC10 

– Vanne Ch/Rafr => Ch 

NO11 

– Multifunktionsausgang 

NO11 

– Multifunctional exit 

NO11 

– Sortie multifonction 

NO12 

– Stetiges Kühlsignal 

NO12 

– Continuous cooling signal 

NO12 

– Signal rafraîchissement 

constant 

NO13 

–  

NO13 

–  

NO13 

–  

Содержание EcoTouch DS 5027 Ai

Страница 1: ...tallation EcoTouch DS 5027 Ai Heating System WATERKOTTE GmbH Gewerkenstra e 15 D 44628 Herne Tel 0049 0 2323 9376 0 Fax 0049 0 2323 9376 99 E Mail info waterkotte de Internet http www waterkotte de Z2...

Страница 2: ...en approval by WATERKOTTE GmbH Illustrations and diagrams serve as explanatory description and shall not be used as drawings for construction offers or installation All specifications comply with the...

Страница 3: ...tion 13 4 1 Heating system EcoTouch DS 5027 Ai 13 4 2 Installation 13 4 2 1 Heat pump system series EcoTouch DS 5027 Ai 13 4 2 2 Heat pump module 13 4 3 Electrical equipment 14 4 3 1 Electrical resist...

Страница 4: ...thermostat settings 33 8 3 Installation instructions for external sensor 33 8 3 1 Cabeling 33 8 4 Electrical connections 34 8 4 1 EcoTouch DS 5027 Ai 3x 400 V 34 8 4 2 EcoTouch DS 5027 Ai 1x 230 V 35...

Страница 5: ...ans that electrical and electronic equipment at the end of its useful life shall be disposed of separately from household waste Please dispose of this equipment at your designated collection point or...

Страница 6: ...rk Equipment ordinance Keep all safety and operating signs on the heat pump in fully legible condi tion at all times Replace damaged or illegible signs immediately 1 2 2 Before initial use Before init...

Страница 7: ...vant usage and safety requirements Parts and special equipment not delivered by WATERKOTTE are not ap proved for use on the heat pump 1 3Hazards Observe the following points to avoid life threatening...

Страница 8: ...uching electronic Ground yourself before touching electronic components Risk of total loss Repeated restart of heat pump can result in total loss In case of heat pump failure before restart an inspect...

Страница 9: ...an only be ensured by taking all necessary measures As operator of the heat pump it is your responsibility to plan these measures and oversee their implementation You must ensure that The heat pump is...

Страница 10: ...ed as heat source WQ is the ground It is also possible to cool a building To utilise ground as thermal energy for domestic water heating and cool ing in your home you need the following a heat source...

Страница 11: ...06 10 11 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 3 Product description 3 1Overview connected device Figure 2 Heating system EcoTouch DS 5027 Ai 1 ON OFF switch 2 Control panel electro...

Страница 12: ...ion 2005 06 10 12 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 3 2 Overview unit opened Figure 3 EcoTouch DS 5027 Ai Top view opened 1 Safety group with manometer relief valve bleeder 2 Con...

Страница 13: ...y Con Mobile software diagnosis system All hydraulic connections are placed on the back side All modules in the frame work are law vice fitted with removable heat and sound insulated housing color sig...

Страница 14: ...ernally to facilitate installation in the rear panel frame 4 4 1 Heatsource Consisting of heating circulation pump speed controlled energy class A air separator with automat air diverter filling press...

Страница 15: ...anual for heat pump control 4 5Options Domestic hot water thermo storage charging storage heating side pota ble water heater temperature sensor three way valve Expansion kit For pool heating thermal u...

Страница 16: ...ring direct sun exposure The heat source must be suitable for cooling operation Particularly suita ble are Geothermal energy probes heat source is regenerated with renewable energy from your building...

Страница 17: ...are Geothermal energy probes heat source is regenerated with renewable energy from your building thermal planning is essential Groundwater with groundwater cooling operation is practically unlim ited...

Страница 18: ...g the unit to prevent hand injuries from cooling fins or other parts Observe the transport instructions on the package Observe the specified storage requirements The units may not be stacked Machine m...

Страница 19: ...During transport it must be ensured that appropriate means of transport are used lift truck transport rollers handcart Unit must be transported upright Transport in tilted position 45 is permitted onl...

Страница 20: ...clearance in front at least 1 000 mm 6 1Environmental conditions for installation Note the minimum volume of the installation room and consider the type of the refrigerant EN 378 1 The room must be d...

Страница 21: ...tructure borne noise insulation 6 2 1 Laying a foundation for acoustic heat pump 1 Heat pump 2 Noise absorbent mat Polyethylen PE 3 Insulation material 3 layer polyurethan rubber 4 Supporting subsurfa...

Страница 22: ...ons insert and press 6 3 1 Removing the housing A disassembly tool is delivered with the heat pump Use this tool to avoid damage while you are removing the housing parts The housing parts are removed...

Страница 23: ...pipes and other steel components in the water circuit shall not be used when connecting diffusion open surface heating system In exceptional cases an effective corrosion inhibitor must be added and a...

Страница 24: ...reated according to VDI 2035 e g with corrosion inhibitor To find the volume flow at heating side for the corresponding heat pump please refer to the performance table chapter 16 5K spread The heating...

Страница 25: ...ly and the mainte nance instructions of the supplier must be followed strictly Heating systems with radiators require the installation of a buffer tank connected in parallel see diagrams The size of t...

Страница 26: ...l pipe thread for flat sealing connections with union nut and insert The heat pump is equipped with a 12 l pressure expansion tank A circulation class A pump is installed at heat source side Heat pump...

Страница 27: ...A 25 1 7 25 1 7 25 1 7 25 1 7 25 1 8 25 1 8 25 1 8 25 1 8 Residual head T 4K mWS 6 4 6 1 5 7 5 2 6 7 6 2 5 3 4 5 Residual head heating side W10 B8 4 W35 Heat pump EcoTouch DS 5008 5Ai DS 5010 5Ai DS...

Страница 28: ...Groundwater heat source For groundwater heat pumps the installation of a separation heat exchanger is absolutely essential to avoid direct damage to the heat pump The inter mediate circuit must be fi...

Страница 29: ...h 0 0 0 0 0 Ammonia NH4 2 2 20 20 in the space of 24 h 0 Chloride Cl up to 60 C 300 300 no limit 0 0 Free chlorine Cl2 1 1 5 5 in the space of 24 h 0 0 0 Sulphide SO3 1 1 5 5 in the space of 24 h 0 0...

Страница 30: ...sor on with a time delay to pump heat source The start of the compressor is only enabled if the min imum water volume is present during the lead time and the limit indicator did not respond This devic...

Страница 31: ...ation according to regulations and initial commissioning For electrical installation the regulations of VDE EN as well as of EVU must be observed For wiring standard lines must be used Mains connectio...

Страница 32: ...y consumption must be attributed to construction costs and not to heating costs What must be considered when heat pump functions as heat generator When a heat pump uses groundwater as heat source the...

Страница 33: ...n according val ue e g 6 C the EWE also automatically connects when value drops be low this limit thus relieving the heat source 8 2 3 Heat generator thermostat settings The thermostat of the heat gen...

Страница 34: ...Electrical work 2005 06 10 34 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 8 4Electrical connections 8 4 1 EcoTouch DS 5027 Ai 3x 400 V...

Страница 35: ...Electrical work 2005 06 10 35 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 8 4 2 EcoTouch DS 5027 Ai 1x 230 V...

Страница 36: ...Electrical work 2005 06 10 36 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 8 4 3 Connectors...

Страница 37: ...sseur 1 Y5 Kompressor 2 Y5 Compressor 2 Y5 Compresseur 2 Di1 St rmeldung Quelle Di1 Failure message source Di1 Message de panne captage Di2 St rmeldung Heizung Di2 Failure message heating Di2 Message...

Страница 38: ...ATERKOTTE GmbH Subject to changes 9 Pipe instrumentation flow chart measurement control technology EcoTouch DS 5027Ai and EcoTouch DS 5027Ai NC EcoTouch DS 5027Ai RC TIC TIC TIC TIC TIC PIC 8 1 2 3 4...

Страница 39: ...erature readout in the controller display and control in the electrical switchboard NTC 10K gauge condenser IN Heating return PIC 5 Measurement of pressure readout in the controller dis play and contr...

Страница 40: ...10 40 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 07 08 09 10 13 12 11 14 01 02 04 03 06 05 M M 16 17 15 10 Hydraulic diagramms DS 5027Ai DS 5027Ai NC RC Heat pump EcoTouch DS 5027Ai and...

Страница 41: ...fill and drain valve heating 06 expansion tank heating 07 circulation pump heating 08 electronical heating element heating 09 air separator heating 10 safety group heating 11 safety group heat source...

Страница 42: ...mpliance with safety instructions Activate all safety devices and emergency stop switches prior to com missioning Check motor for correct direction of rotation prior to commissioning Also read chapter...

Страница 43: ...it breakers ground fault interrupter isolating switch B fuse and molded case circuit breaker with the specified capacity If the circuit break er capacity is larger than required this can have a system...

Страница 44: ...saved settings remain saved even in case of power failure Info During initial start up the specified limits are often exceeded thus numerous warning messages could appear For this reason the warning...

Страница 45: ...operation wait at least five minutes before turning main pow er switch off Otherwise there is a risk of water leak or unit failure Procedure Turn OFF the main switch of heat pump Turn OFF LS switch C...

Страница 46: ...Insufficient refrigerant see inspection glass Incorrect setting of controller parameter Sensor incorrectly aligned or insufficiently attached 12 1 2 Fault at output side HP fault Motor protection of...

Страница 47: ...ion regulations for cooling de vices In any case it will result in exclusion of warranty The high pressure pressostat is placed in the pipe of the refrigerant medium at the exit of the condenser Shift...

Страница 48: ...modynamic section ensures that the efficiency is main tained on the top Typical inspection Check heating circuit System pressure function of expansion tank venting rotation direction of pump and volum...

Страница 49: ...Connection diagrams 2005 06 10 49 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes 15 Connection diagrams...

Страница 50: ...Connection diagrams 2005 06 10 50 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 51: ...Connection diagrams 2005 06 10 51 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 52: ...Connection diagrams 2005 06 10 52 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 53: ...Connection diagrams 2005 06 10 53 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 54: ...Connection diagrams 2005 06 10 54 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 55: ...Connection diagrams 2005 06 10 55 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 56: ...2 Kelvin 21 membrane expansion tank for potable water systems 22 membrane expansion tank with shut off fitting 23 domestic cold water 24 domestic hot water DHW 25 circulation 26 potable water heater...

Страница 57: ...valve 70 safety group with relief valve pressure reducer backflow preventer and membrane expansion tank with perfusion armature for potable water systems 71 215 liter plastic case 72 hopper 73 immersi...

Страница 58: ...B A 46 5 47 0 48 0 49 0 48 0 49 5 51 5 50 0 Electrical data 3x400 V 50 Hz Type 1x230 V 50 Hz Unreduced starting current A 26 58 38 67 46 98 43 128 51 5 115 5 64 75 101 Starting current with soft start...

Страница 59: ...Technical Data 2005 06 10 59 60 Copyright 2013 by WATERKOTTE GmbH Subject to changes...

Страница 60: ...opyright 2013 by WATERKOTTE GmbH Subject to changes WATERKOTTE GmbH Gewerkenstra e 15 D 44628 Herne Tel 0049 0 2323 9376 0 Fax 0049 0 2323 9376 99 Service 0049 0 2323 9376 350 E Mail info waterkotte d...

Отзывы: