Commissioning
21.10.2015
44 / 60
Copyright
2014 by: WATERKOTTE GmbH. Subject to changes.
heater has to heat the oil up to operating temperature. This takes
up to 30 min in cool ambient temperature.
3.
Once the operating temperature is reached, the compressor starts.
10.3
Control of entire operation
This heat pump is equipped with an efficient electronic control system. All
necessary settings and options are described in the controller manual.
Tip: The correct use of the controller saves money. Particularly the correct
settings of flow temperature, hot water temperature, heating curve and
heating times can result in substantial cost savings.
10.4
Turning heat pump off
After finishing operation, wait at least five minutes before turning main pow-
er switch off. Otherwise, there is a risk of water leak / module failure.
Procedure:
Switch off main switch of heat pump.
Switching off circuit breaker: Compressor, control voltage and electrical
heating element.
10.5
Taking heat pump out of operation for extended period
- see 10.4-
Total loss (freezing)
At low outdoor temperatures the device and the pipes must be protected
from freezing.