background image

 

15 

 

 

 

Date 

Line  

System  Permeate  Feed Water  Pre-Filter  Fast   Permeate 

Waste 

  

Pressure  Pressure 

TDS 

TDS 

Change  Flush  Flow Meter Flow Meter 

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

 

 

 

 

 

Содержание Vectapure RSXII LITE

Страница 1: ...SES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL...

Страница 2: ...taminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RSXII Lite RO system use Vectapure RSXII Lite systems use two stages of tre...

Страница 3: ...ak usage of water for the combined equipment does not exceed the output of your RO system or its product water storage See your dealer for advice and parts Q What factors affect the quantity and the q...

Страница 4: ...orating and is losing its effectiveness Where the RO is used as a pre treatment for a process requiring water to exact standards you should adopt a regular ongoing sampling and testing procedure to en...

Страница 5: ...e Pre treatment by carbon filtration is very effective for chlorine reduction carbon eventually becomes exhausted and must be replaced to ensure continuous filtration If stabilized chlorine is present...

Страница 6: ...eation Fouling may occur as layers of deposition on the surface of the membrane cake fouling a hardened layer on the membrane surface scale particle insertion into the pore channel or entrance pore bl...

Страница 7: ...lorine 1 ppm Permanent membrane damage Increased salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adj...

Страница 8: ...itized before use and periodically disinfected RO product water will have no chlorine residual and will be subject to contamination at all stages in the plumbing system Consider UV disinfection as an...

Страница 9: ...s TDS Monitor Reject flow meter Permeate flow meter 1 4 Drain Connection membrane housings Auto Shut Off Valve 3 8 Feed Water inlet 3 8 Permeate Outlet Housing 5 micron Pre Filter Levelling feet Figur...

Страница 10: ...on the drain line over the drain and secure it in place Do not elevate the drain line over 10 feet from the floor If connection to a sewer line is necessary check the local code or a plumbing professi...

Страница 11: ...1000 to 2000 Orifice colour codes are as follows 500 TDS Black 501 1000 TDS Lilac Make sure that you have the correct orifice plate fitted to your system This orifice has been selected to operate at...

Страница 12: ...ILL CAUSE PREMATURE MEMBRANE FAILURE OR INTERNAL SCALING AND EQUIPMENT FAILURE Section 5 System Maintenance Changing Pre filter Cartridges The pre filter cartridges should be changed as a rule of thum...

Страница 13: ...eter to verify the initial reading The membrane element life will range from 1 to 5 years depending on the quality of the raw water See S 3 7 2 for membrane removal and installation instructions If yo...

Страница 14: ...pre filter cartridges Low feed water pressure Check feed water source for restrictions Malfunctioning pressure gauge Replace gauge High System Pressure Plugged or restricted concentrate orifice Clean...

Страница 15: ...14 Section 7 VectapureTM RSXII Lite Performance Log Date Line System Permeate Feed Water Pre Filter Fast Permeate Waste Pressure Pressure TDS TDS Change Flush Flow Meter Flow Meter...

Страница 16: ...15 Date Line System Permeate Feed Water Pre Filter Fast Permeate Waste Pressure Pressure TDS TDS Change Flush Flow Meter Flow Meter...

Страница 17: ...e An RSXII Lite has 2 membranes each nominally rated at 400 gpd and the raw water temperature is 9 0 degrees Celsius 2x400 2 350 gpd Temperature Corrected Of course the actual production of your syste...

Страница 18: ...17 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Страница 19: ...18 THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY...

Страница 20: ...19 WATERITE INC Winnipeg Manitoba Canada www waterite com...

Отзывы: