Use a float switch for draining or filling. 

 

Use pressure switch for water pressure boosting. 

 

Or manual start stop switch for water circulation etc. 

Care & Maintenance

 

Always watch your power supply voltage or current for over voltage, under voltage or short 
circuit. 

 

Make sure your pump filter sieve is always clean of debris or any clogging dirty. 

 

Careful attention will guarantee outstanding pump performance  
 

Parts:

 

 

 

 

 

 

thth

SUITABLE FOR USE;

 

FL35 used in a R.V. open flow is 12.5 litres per minute, choked to 7 litres per minute.  The 
FL35 is NOT suitable for a 6 -5.5 litres per minute Gas Geyser.  The FL30 @ 7 – 4.5-5 litres 
per minute would be the correct pump. 
  

Pro Pumps used in Mobile Toilets

 

The FL40 ‘s flow is too high for the ball valves at 17 - 11 litres per minute and only suitable 
if used with a float switch.  The best pump for Mobile Toilet Application would be the 

FL35 

VITON

 

  

Causes for Failures

 

1. Leaks on the system will cause the pump to cycle.  The Pressure Switch will 
fail Examples:  poor connection, Gardenia fittings, Ball valve not shutting off properly. 
  
2. Low voltage will allow pump to run continuously and not reach the cut off pressure of 2.4 
bar, this will cause the motor to burn out eventually. 
  
3. Application in mobile toilets; the VITON pumps will stand the best chance against 
chemical attack.  Beware of inconsistent Formaldehyde strengths (i.e. toilets placed far from 
sight will receive a stronger solution.) 
  
Please feel free to contact us if we can be of further assistance regarding the correct 
application of our Waterhouse Pumps. 