Important: Always allow the system at least five minutes to

respond to any changes in settings. The thermostat has been pro-
grammed to start the heating or cooling cycle in
stages.

Note: The electronic thermostat cannot be

set closer than 3

o

 between heating and

cooling.

How do I set my

thermostat?

Mode button

Push and release the 

MODE 

button to select the desired

mode of operation.  Each time the 

MODE

 

button is pushed and released, the thermostat will

select a different mode. The different modes are as follows (in sequence):

OFF

System will not operate

COOL

Cooling operation only

HEAT

Heating operation only

AUTO

Heating or cooling operation

E HEAT

Heating with auxiliary heat only

Heat

Push and release the 

MODE

 button until the display

reads 

HEAT

.  Your system is now in the heating mode.

To review the heating setpoint, momentarily  press either
the 

 or  

  button and you will see your current

setpoint displayed along with the words 

DESIRED TEMP

illuminated on the display.   The display will read 

HEAT

 and 

ENERGY SAVINGS

 when

the system is operating in either the first or second stage heating mode.  The heating cycle
starts with the fan and compressor on a lower speed.  (For single-speed units there is only one
compressor speed.)  This lower fan speed reduces the sound level and increases air tempera-
ture.  Note: It is normal for the Premier two-speed GeoExchange system to have extended run
times in low speed. The Premier two-speed is the most efficient in low speed operation. Should
the thermostat require maximum heat, the fan and compressor will switch to a higher speed.
(For single-speed units there is only one compressor speed.)  During extreme cold weather,
additional heating capacity may be required.  At such times, the thermostat will automatically
request auxiliary heating assistance, and display the words 

AUX HT

. The 

ENERGY

SAVINGS

 on the display is not illuminated when auxiliary heat is being used.

Содержание Premier2

Страница 1: ......

Страница 2: ...Benefits 3 How GeoExchange Systems Work 4 GeoExchange System Types 5 WaterFurnace Quality Commitment 6 Warranty 6 Thermostat Operating Procedures 7 12 Premier2 Status Lights 12 14 System Maintenance 1...

Страница 3: ...mney or odors backed by the industry s best warranties low maintenance requirements improves the environment by not burning fossil fuels no carbon monoxide emissions Energy Efficient GeoExchange syste...

Страница 4: ...derground pipe absorbs heat from the earth and carries it to the Premier2 unit which extracts the heat compresses it to a higher temperature and distributes it via a duct system During the cooling sea...

Страница 5: ...h as a ditch field tile pond or stream An open loop system may require periodic inspection cleaning to prevent buildup of mineral deposits Closed loop systems The GeoExchange closed loop system is an...

Страница 6: ......

Страница 7: ...e Note WaterFurnace offers several different thermostats that can be used with your Premier2 system The instructions that follow apply only to the type of thermostat pictured here For operating instru...

Страница 8: ...either the or button and you will see your current setpoint displayed along with the words DESIRED TEMP illuminated on the display The display will read HEAT and ENERGY SAVINGS when the system is ope...

Страница 9: ...removal and reduces sound levels Note It is normal for the Premier two speed GeoExchange system to have extended run times in low speed The Premier two speed is most efficient in low speed operation S...

Страница 10: ...ush and release the MODE button until the display reads OFF When the word OFF is displayed the system will not provide heating or cooling The display still shows room temperature and the fan is operab...

Страница 11: ...airflow Check clean or replace filter Reset the unit see page 15 If unit still does not operate or the TROUBLE display is still on call your WaterFurnace dealer What if the words CLEAN FILTER are disp...

Страница 12: ...ing slowly operation may seem normal but there is a problem Call your WaterFurnace dealer for assistance TYPICAL INSTALLATION Filter Rack Flow Center Status Lights To Loop What do I need to know about...

Страница 13: ...reezing conditions have occurred This may be caused by a pump failure low antifreeze level or air pockets in the loop piping see resetting the unit section page 15 Low Pressure When this light is on i...

Страница 14: ...ols does my unit have Your WaterFurnace Premier2 unit is equipped with safety controls which are designed to protect the unit in case of improper airflow water flow or refrigerant charge These safety...

Страница 15: ...ae To gain access to the drain pan for inspection Turn off all power to unit and auxiliary heat Remove the screw located above the top center of the fan compartment door Lift the door up and pull out...

Страница 16: ...ure the thermostat is set properly Check to make sure the electrical disconnect switches are in the ON position Both the unit and auxiliary heat if present must be powered for proper operation Check f...

Страница 17: ...Date of Purchase Type of System Closed Loop Open Loop Well Water Pond Loop Auxiliary Heat Yes No If yes what kW Loop Length Unit Model Serial Options Extended Warranties Equipment Loop Once again than...

Страница 18: ...18 Premier2 Owner s Manual Notes...

Страница 19: ...19 Premier2 Owner s Manual Notes...

Страница 20: ......

Отзывы: