Choose the System Setting (Heat, Off, Cool, Auto)

Press the SYSTEM button to select: 

Heat

: Thermostat controls only the heating system. 

Off

: Heating and Cooling systems are 

off. 

Cool

: Thermostat controls only the cooling system. 

Auto

: Auto Changeover is used in areas where both heating and cool-

ing may be required on the same day. 

AUTO

 allows the thermostat to automatically select heating or cooling depending on the 

indoor temperature and the selected heat and cool temperatures. When using 

AUTO

, be sure to set the Cooling temperatures 

more than 1° Fahrenheit higher than the heating temperature.

Manual Operation for Non-Programmable Thermostats

Press the SYSTEM button to select Heat or Cool and use the      or      buttons to adjust the temperature to your desired setting. 
After selecting your desired settings you can also press the SYSTEM button to select 

AUTO

 to allow the thermostat to automatically 

change between Heat and Cool.

Manual Operation (Bypassing the Program) Programmable Thermostats

Press      or      and the HOLD button and adjust the temperature wherever you like. This will override the program. The 

HOLD

 

feature bypasses the program and allows you to adjust the temperature manually, as needed. Whatever temperature you set in 

HOLD

 will be maintained 24 hours a day, until you manually change the temperature or press 

Run

 

Schedule

 to cancel 

HOLD

 

and resume the programmed schedule.

Program Override (Temporary Override)

Press      or      buttons to adjust the temperature. This will override the temperature setting for a (default) four hour override 
period. The override period can be shortened by pressing      or lengthened by pressing     . Program Override period can  
range from 15 minutes to 7 days. 

Example

: If you turn up the heat during the morning program, it will be automatically lowered 

later, when the temporary hold period ends. To cancel the temporary setting at any time and return to the program, press 

Run 

Schedule

. If the SYSTEM button is pressed to select 

AUTO

 the thermostat will change to Heat or Cool, whichever ran last. If 

it switches to heat but you want cool, or it changes to cool but you want heat, press both      or      buttons simultaneously to 
change to the other mode.

PROGRAMMING

Set Current Time and Day

1) Press Menu and then Set Time button once. The display will show the hour only.
2) Press and hold either the      or      key until you reach the correct hour and AM/PM designation (AM begins at midnight,
 

PM begins at noon).

3) Press Set Time once again. The display window will show the minutes only.
4) Press and hold either the      or      key until you reach the correct minutes.
5) Press Set Time once again. The display will show the day of the week.
6) Press the      or      key until you reach the current day of the week.
7) Press Run Schedule once. The display will show the correct time and room temperature alternately.

Enter the Heating Program

1) Press the Menu button and then press Set Schedule. Press SYSTEM button to select either “Heat” or “Cool” in the system 
 

switch area indicating the active mode being programmed. You can switch to the other mode by pressing the system switch at 

 any 

time.

2) The top of the display will show the day(s) being programmed. The time and set at temperature are also displayed. “Morning”  
 

will also be displayed to indicate the period.

3) Press      or      key to change the temperature to your selected temperature for the 1st heating period (Morning).
4) Press      or      key to adjust the start time for period.
5) The time will change in 15 minute increments.
6) After you have set the time and the temperature for the period to begin, press Set Schedule to advance to the next program period.
7) Repeat steps 2 through 6 until all of the program times and temperatures are set for all program periods on that day.
8) Press “Advance Day” to change to the next day and repeat steps 2 through 8.
9) When programming is complete and all of the times and temperatures match your desired heating schedule, press Run
 

Schedule. The thermostat will now run your program.

Enter the Cooling Program

1) Press the SYSTEM button until the Cool icon appears.
2) Follow Enter Heating Program instructions for entering cooling times and temperatures.

For more information on thermostat operation, refer to the instruction manual shipped with your thermostat.

THERMOSTAT OPERATION

TP32W02 Thermostat - Continued

Содержание Geothermal heating and cooling system

Страница 1: ...Owner s Manual...

Страница 2: ...ny years of exceptional performance comfort and savings For a quick reference write your WaterFurnace Dealer s name telephone number and other important information below Company Name Telephone Number...

Страница 3: ...ial Size of Home Under 1500 square ft 2500 to 4000 square ft 1500 to 2499 square ft Over 4000 square ft Location of Home Rural Suburban Urban Value of Home Under 100 000 100 000 to 200 000 200 001 to...

Страница 4: ...WATERFURNACE INTERNATIONAL ATTN WARRANTY REGISTRATION DEPT 9000 CONSERVATION WAY FORT WAYNE IN 46809 9794 Place Stamp Here...

Страница 5: ...at Operation 26 27 HOMEOWNER MAINTENANCE 28 29 TROUBLESHOOTING 30 FAQs GENERAL INFORMATION OPERATING TIPS 31 38 ENERGY SAVING TIPS 39 PRODUCT INFORMATION FOR UNITS ACCESSORIES 40 Model Number Serial N...

Страница 6: ...rkmanship Like your refrigerator your geothermal unit will provide many years of worry free operation Quiet Unlike ordinary air conditioners or heat pumps there is no noisy outdoor unit Our units are...

Страница 7: ...presents 500 times more than mankind needs every year 5 units of heating or cooling delivered into your home 1 unit of electricity 4 units of free energy from the earth ABOUT YOUR WATERFURNACE SYSTEM...

Страница 8: ...ater or water and anti freeze is circulated through the pipe transporting heat to the heat pump during the heating mode and away from the heat pump during the cooling mode The heat transfer takes plac...

Страница 9: ...per wall separating the two This heat transfer causes the cold liquid refrigerant to turn into a gas Unlike water refrigerant changes from a liquid into a gas at a very low temperature The now gaseous...

Страница 10: ...w to go in the opposite direction that it was in the heating mode However the flow to the compressor does not change direction After compression the hot refrigerant passes through the coax the condens...

Страница 11: ...odel and run time of the unit On very hot days and cold days the hot water generator could produce more hot water required for the home due to the long run times of the unit On milder days when the un...

Страница 12: ...oop earth coupled system include Geothermal unit placed on mounting pad Thermostat Earth loop piping Earth loop circulators pumps Electrical supply Duct system except for radiant floor heating systems...

Страница 13: ...generator used Auxiliary heater if used Electrical Flexible Duct Collar Vibration Absorbing Pad P T Plugs Condensate Drain Desuperheater Connections Auxiliary Heater Knockout Low Voltage to Thermosta...

Страница 14: ...then connected to a header system horizontally a few feet below the surface If you have this loop type record information here Number of bore holes _____ Depth of each bore hole _____ Pipe size _____...

Страница 15: ...loop is located Include the house and measurements from various points so that there is no question about the location of the piping system You may also want to include the location of any underground...

Страница 16: ...egin to clog the heat exchanger in the unit When this happens the efficiency and capacity of the unit is decreased eventually to the point where failure may occur To minimize the potential of this hap...

Страница 17: ...ns adhere to these safety precau tions Replacing a disposable filter Turn off the unit and fan at the thermostat Cleaning an electrostatic filter Turn off the unit and fan at the thermostat Cleaning a...

Страница 18: ...sidered to be any factory installed component inside the unit including but not limited to the compressor reversing valve expansion valve electrical components air coil heat exchanger etc Upon failure...

Страница 19: ...e warranty cer tificate carefully to familiarize yourself with the terms of the warranty so that you can obtain full benefits and avoid misunderstandings If you have any questions about warranty cover...

Страница 20: ...ures and options along with a more aesthetically pleasing look Although these thermo stats are significantly more high tech you ll find that they are easy to operate Note Most thermostats have an auto...

Страница 21: ...orresponding pages for instructions on usage These thermostats also come with an individual Owner s Guide which includes additional information For thermostats NOT shown here refer to separate Owner s...

Страница 22: ...the SYSTEM mode is in HEAT Flame icon is displayed flashing when 2nd stage heat Aux or Emergency is energized Snowflake icon is displayed non flashing when the SYSTEM mode is in COOL Snowflake and Fl...

Страница 23: ...System Changeover When the thermostat is in the AUTO mode both the Flame and Snowflake icons are displayed The thermostat will call for heat or cool depending on the room temperature The setpoint temp...

Страница 24: ...eries are low with no system power Displays current temperature or LO when batteries are low Displays currently programmed set temperature this is blank when SYSTEM is OFF Displays FLTR when the syste...

Страница 25: ...HEAT setpoint will be displayed If the room temperature raises above the HEAT setpoint and the COOL setpoint and a for cool is required the temperature displayed will change to be the COOL setpoint S...

Страница 26: ...e current day Used to advance operation to the next program period or advance to the next day in programming mode Used to manually override programming to hold at a selected temperature Used to view a...

Страница 27: ...hrough the entire schedule entering time and temperature for each period When you are satisfied that your program matches your schedule press PROGRAM Programming is now complete for this mode and your...

Страница 28: ...er configuration The words Hold At are displayed when the thermostat is in the HOLD mode Temporary Hold At is displayed when the thermostat is in a temporary HOLD mode Call For Service indicates a fau...

Страница 29: ...s to heat but you want cool or it changes to cool but you want heat press both or buttons simultaneously to change to the other mode PROGRAMMING Set Current Time and Day 1 Press Menu and then Set Time...

Страница 30: ...from your WaterFurnace dealer Electrostatic Filters Clean every 1 2 months If you use an electrostatic filter clean it regularly See page 54 for instructions Electronic Air Cleaners Clean and replace...

Страница 31: ...place disposable filter 2 4 Clean electrostatic filter if used Clean electronic air cleaner if used Check condensate drain pan Check duct system Check thermostat operation and signals Visual check of...

Страница 32: ...breaker Call for service 35 Thermostat settings mysteriously change Check setpoints for both heating and cooling 20 Red LED on at thermostat Check status fault lights on unit See thermostat instructi...

Страница 33: ...system you ll find this information valuable Geothermal systems do function differently than ordinary systems However by using this section as a reference you ll be able to find answers to the most co...

Страница 34: ...ion has ceased look at the thermostat to see if the unit lockout indicator light is illuminated If the lockout indicator light is illuminated see resetting the unit section page 33 What about regular...

Страница 35: ...control which is the brain of the unit is operat ing properly If the light doesn t flash but remains continuously on or off the control is inoperative Turn off all power to the unit including auxiliar...

Страница 36: ...asily washed Never run the unit without a filter The frequency in which you should clean or replace your filter is dependent upon several variables including the type of filter media your outdoor envi...

Страница 37: ...er assist is a function of how long the unit is running and in what mode it is in With the hot water assist more water is heated in the cooling mode than in the heating mode For more information see p...

Страница 38: ...few min utes followed by a cooling off period then another blast of hot air and on and on This type of operation results in ever changing indoor temperatures and hot cold spots within the home This f...

Страница 39: ...so that the air is fully circulated throughout the various rooms to minimize hot spots or cold spots When the guests leave and occupancy levels return to normal be sure to switch back to heating mode...

Страница 40: ...tized in any way Indoor air quality can be improved using special ultra violet UVC lights placed in the air distribution system Al though these lights do not remove any contaminants you ll still need...

Страница 41: ...cient to seal leaks in a duct system Over time the adhesive used on duct tape will dry out resulting in tape failure Other tape types and sealants used by professional HVAC contractors are better suit...

Страница 42: ...experienced the information provided here will help you to better understand the specific features of your unit We have also included information on major options and accessories how they work and wh...

Страница 43: ...r more models The five families of units are Envision E Series Premier Synergy3 Versatec If your unit has a model number starting with E you have an E Series unit E Series units are available in E ES...

Страница 44: ...irflow for your installation In addition the ECM motor will automatically speed up or slow down depending on the mode or stage of operation The unit has the ability to operate in a special dehumidific...

Страница 45: ...components during operation for optimum performance with the ability to signal various fault conditions see page 33 The microprocessor also provides easy to use trouble shooting features and on board...

Страница 46: ...ity does not satisfy the thermostat the unit will automatically change to second stage full capacity compressor operation In order to change from first stage to second stage units with dual capacity c...

Страница 47: ...change the setpoint by one degree In addition to the water temperature display the control panel also has 6 LED indicators that indicate when the unit is in one of the following modes Lockout Standby...

Страница 48: ...reeze protection and fan start detection In the unlikely event of a compressor failure the emergency heat is enabled to satisfy heating requirements Another sensor detects if the condensate drain pan...

Страница 49: ...perate after resetting do not attempt another reset as doing so may damage the unit or components Contact your dealer for service Like our other Premier series products Premier split units utilize R 2...

Страница 50: ...cy heat is enabled to satisfy heating requirements Another sensor detects if the condensate drain pan is full at which time the unit will be shut down for protection against water leaks see page 33 De...

Страница 51: ...t your dealer for service In northern climates Versatec units may include an optional duct mounted auxiliary heater In the unlikely event of a compressor failure the auxiliary heater will provide emer...

Страница 52: ...eater could generate more hot water required for the home due to the long run times of the unit On milder days when the unit has short duty cycles the electric elements in the water heater will mainta...

Страница 53: ...example Installation Option A The geothermal unit is sized to provide 95 of your heating requirement with the other 5 using the auxiliary electric Installation Option B The geothermal unit is sized to...

Страница 54: ...ent Instead water is distributed over a rotating disk wheel Air passing through the humidifier picks up the moisture from the disk wheel and is routed into the home through the duct system providing v...

Страница 55: ...he unit On the Powerhead of the air cleaner unplug the adapter cord Make sure that the jack does not touch any metallic or grounded surfaces which could result in possible damage to the unit Remove th...

Страница 56: ...ldup is very heavy you may want to use a vacuum cleaner hose to remove the bulk of the accumulation This may not be necessary unless the filter is very dirty Spray the filter on both sides with a hous...

Страница 57: ...arate switch conveniently located in the home By utilizing the AlpinePure HRV for bathroom ventilation ordinary noisy exhaust fans are eliminated and fresh outdoor air is introduced indoors without a...

Страница 58: ...moving large numbers of the smallest particles Other less efficient filtration tech nologies rate the efficiency in terms of weight not volume of particles captured It s easy to understand that larger...

Страница 59: ...ticles including pollens mold spores dust fungal spores and pet dander In addition these filters are pleated to increase the surface area allowing for more holding capacity and less frequent replaceme...

Страница 60: ...r the use of a single larger pump or possibly separate loops and pumps for each unit Units using well water do not use a flow center Rather they use the well pump Maintenance Flow centers and pumps re...

Страница 61: ...zoning to eliminate uneven temperature control between the basement and the rest of the home Large homes that might have long unequal length duct runs can use zoning to equalize the delivery of condit...

Страница 62: ...the spread of germs In addition to the health benefits offered with this technology equipment efficiency can be im proved by the fact that the air coil is kept cleaner These components consume about...

Страница 63: ...a great variety of name brand shirts jackets caps and other items with the WaterFurnace logo To view our complete product selection go to www waterfurnace com and click on WaterFurnace merchandise All...

Страница 64: ...natural gas propane fuel oil oil and coal GPM Gallons per Minute A reference to the flow rate of water through the geothermal unit Heat Exchanger A device designed to transfer heat between two physic...

Страница 65: ...22 2023 2024 2025 2026 2027 2028 2029 2030 PREVENTIVE MAINTENANCE SERVICE RECORD PREVENTIVE MAINTENANCE SERVICE RECORD In order to keep your system operating at peak performance levels WaterFurnace re...

Страница 66: ...Document Type Owner s Manual Part Number OM2006 Release Date 08 06 OM2006...

Отзывы: