FLOW CENTER INSTALLATION AND LOOP FLUSHING MANUAL

Flow Center Initial Inspection

Please read the complete instructions before starting installation. Carefully follow instructions to ensure optimum and 

safe operation. Leave the instructions with the owner after installation. The GeoLink

®

 Flow Center and UP Series circulating 

pumps should be installed according to all applicable codes. Unpack the fl ow center and any other component kits required 
and inspect them for shipping damage. Shipping damage claims must be fi led promptly by the purchaser with the freight 
company.

Verify the contents of this package with the following list:
 

(2)  Lag screws 1/4'' X 2.5''

 

(4)  Long sheet metal #10 X 3/4'' screws (for mounting on unit)   

 

(2)  1" MPT Brass plug (Not included with FPTB or GL series)

 (1) 

Decal

 (1) 

Installation 

manual

 

(2)  1-1/4'' PE Socket Adapters (GL models only)

Notes: 

The fl ow centers are injected with foam for condensation prevention during low temperature operation and for noise 

attenuation. Pump heads can be fi eld replaced.

Typical Installation

The Flow Centers are insulated and contain all fl ushing and circulation connections for residential and light commercial 

earth loops which require a fl ow rate of no more than 20 gpm. One-inch female pipe thread fi ttings are furnished with FC1-
FPT, FC1-FPTB, FC2-FPT and FC2-FPTB units for loop connections. Various fi ttings are available for FC1-GL and FC2-GL 
units for loop connections. See Adapter Sets table below and Connection Options table (page 5) for all adapter fi ttings.

Typically, one-pump fl ow centers are used on 3-ton and smaller systems, and two-pump fl ow centers are used on 3.5-ton 

to 6-ton systems. However, this is a rule of thumb, and should always be verifi ed by a pressure drop calculation. 

See "Pres-

sure Drop Calculation Manual" or use Pressure Drop software program to determine correct pump selection.

WARNING: 

Before performing service or maintenance operations on the system, disconnect all power 

sources.  Electrical shock could cause personal injury.  Before applying power, make sure that all covers 
and screws are in place.  Failure to do so could cause risk of electrical shock.

PART NO.

DESCRIPTION

CONNECTION USE

FLOW CENTER 

TYPE

MA4INS

1

" MPT to 1" INS (Hose Barb)*

Loop or unit side connection

FPT

MA5INS

1

" MPT to 1-1 /4" INS (Hose Barb)*

Loop or unit side connection

FPT

MA5PES

1

" MPT to 1-1/4" PE (Socket Fusion)

Loop side connection

FPT

MA4SWV

1” MPT to 1” Swivel Union

Unit side connection

FPT

GL4INS

1

"

 GeoLink fi tting x 1

"

 Hose Barb

Unit side connection

GL

GL4PES

1

"

 GeoLink fi tting x 1

"

 Socket Fusion

Loop or unit side connection

GL

GL5PES**

1

"

 GeoLink fi tting x 1-1/4

"

 Socket Fusion

Loop side connection

GL

GL-FP

1

"

 GeoLink fi tting x 1

"

  cam lever elbow (male)

Flushing port connection

GL

Adapter Sets (Sets consist of 2 connectors)

Notes:

  *Hose Clamps included with barbed adapter sets.

Safety Considerations

General Installation Information

Содержание GeoLink FC1-GL

Страница 1: ...ng and Charging Procedures Unit Pressure Drop Tables Antifreeze Use Troubleshooting Flow Centers FC1 GL FC2 GL FC1 FPT FC2 FPT FC1 FPTB FC2 FPTB Flush Cart LFC F Flow Center Installation and Loop Flus...

Страница 2: ...Flow Center Model Nomenclature Flow Center Type GL 1 GeoLink Connections w high impact polystyrene cabinet FC 1 GL Number of Pumps FPT 1 Female Pipe Thread Connection w metal cabinet FPTB 1 Female Pi...

Страница 3: ...menclature 2 General Installation Information 4 7 Electrical 8 9 Flush Cart Information 10 Flushing and Charging 11 14 Initial Start up 15 16 Unit Pressure Drop Tables 17 18 Troubleshooting 19 Antifre...

Страница 4: ...s Various fittings are available for FC1 GL and FC2 GL units for loop connections See Adapter Sets table below and Connection Options table page 5 for all adapter fittings Typically one pump flow cent...

Страница 5: ...ough center of brackets into one stud Finished wall drywall mounting notes The flow center can be mounted by using two lag screws through drywall into stud through center holes in top and bottom of ca...

Страница 6: ...UAL Figure 2a FPT Style Flow Center Three Way Valve Position Indicator 1 FPT Access Ports for Flushing 1 FPT Fittings 4 Typical HEAT PUMP CONNECTIONS GROUND LOOP CONNECTIONS 12 38 4 25 13 58 5 88 3 25...

Страница 7: ...P FLUSHING MANUAL Figure 2b GL Style Flow Center A B C D E F G H INCHES 15 0 10 3 7 0 14 0 2 0 2 6 5 0 4 5 CM 38 1 26 0 17 8 35 6 5 1 6 7 12 7 11 4 TYPE SHIPPING WEIGHT FC1 GL 26 LBS FC2 GL 31 LBS Gen...

Страница 8: ...PB1 as shown in Figure 4 The pumps will automatically be cycled as required either by the unit or by a signal from another unit sharing the same flow center Electrical Information Compressor Contacto...

Страница 9: ...it S C Figure 5 Pump Connection Option Figure 6 Pump Connection Option Multiple Units On One Flow Center When two units are connected to one loop pumping system pump control is automatically achieved...

Страница 10: ...ions 1 PVC braid Valves 1 high flow ball valves Pump Drain Integral petcock valve Priming Drilled into pump volute housing integral petcock valve to bleed air Tubing 1 Copper type L Hand Truck Industr...

Страница 11: ...tank reservoir A drop of more than 2 inches indicates that there is air in the loop Power flushing can be achieved using the home s city water supply or well water connected to the flush cart This use...

Страница 12: ...e direction only Flush the lowest portion of the system first Depending upon the individual layout this could be the loop or the unit Restart pump Once you have a steady flow of water on the return si...

Страница 13: ...er Remove caps from flow center access ports Connect flush cart hoses to access ports Position valve stems as shown below Proceed with steps 4 through 8 on page 12 Rotate the flow center valves to iso...

Страница 14: ...er length of garden hose to the other port in the flow center leading to drain Flush flow center and unit with domestic water until all air is removed Close boiler drain valve on discharge hose and pr...

Страница 15: ...d Perform this by deadheading the pump by closing the return hose ball valve This will increase the pressure on the loop via the flush cart pump As the pressure will fluctuate with the seasons higher...

Страница 16: ...hurt the performance However insufficient flow can significantly reduce capacity and possibly even damage the heat pump in extreme conditions Notes Pressure temperature gauges should be lubricated wi...

Страница 17: ...5 16 0 5 8 13 4 E EZ Dual Capacity E036 Low 4 0 1 0 2 2 5 0 1 5 3 4 E036 High 7 0 2 8 6 5 9 0 4 5 10 4 E048 Low 6 0 1 9 4 4 9 0 3 5 8 1 E048 High 9 0 3 5 8 1 12 0 5 6 12 9 E060 Low 8 0 2 0 4 6 11 0 2...

Страница 18: ...0 6 2 14 3 V L X 015 3 0 1 6 3 6 4 0 2 1 4 9 V L X 018 4 0 2 0 4 7 5 0 3 4 7 9 Versatec V L X 024 4 5 3 1 7 2 6 0 6 0 13 9 Horizontal V L X 030 6 0 2 4 5 4 8 0 3 8 8 8 V L X 036 7 0 3 6 8 3 9 0 5 3 1...

Страница 19: ...shaft is rotating Flush the loop to eliminate the air Add pump capacity Replace Check for leaks add fluid flush loop in the earth loop need more than 3 psi Change type of antifreeze Switch Thermostat...

Страница 20: ...slightly less than methanol high price flammable in concentra tions greater than 25 non corrosive and low viscosity Propylene glycol Nontoxic noncorrosive expensive hard to handle when cold poorest h...

Страница 21: ...With reference to 60 F water courtesy of Carbide and Carbon Chemicals Corporation Antifreeze Selection and Use cont 35 10 5 0 10 15 20 25 30 100 90 80 70 60 50 40 30 20 0 10 F by Volume 5 Figure 16 En...

Страница 22: ...16458 6 48 4 77 13165 46 38 35 10 19 19690 20 22 7 79 17206 7 00 4 98 13763 48 21 78 8 13 17954 7 54 5 20 14361 50 23 39 8 47 18703 8 10 5 42 14960 BRINE 4 20 METHANOL 30 F Viscosity 0 002 lbm ft sec...

Страница 23: ...8962 1 65 1 87 6413 0 87 1 43 5603 0 30 0 91 4479 10 27 79 6 31 12419 9 73 4 06 9958 1 99 2 08 7126 1 04 1 59 6225 0 36 1 01 4976 11 32 83 6 94 13661 11 50 4 46 10953 2 35 2 28 7838 1 23 1 74 6848 0 4...

Страница 24: ...of continuous product research and development and reserves the right to change design and specifications without notice Product Flow Center Installation and Loop Flushing Type FC1 GL FC2 GL FC1 FPT F...

Отзывы: