Waterford Fionn 90 o.s.a. and Скачать руководство пользователя страница 7

1.

Leg

2.

Ashtray

3.

Base

4.

Base Heat Shield

5.

Combustion Chamber Base Plate

6.

Fire Door

7.

Side Panels

8.

Inside Fire Door

9.

Door Latch

10.

Top Side of Top Baffle

11.

Back Panel

12.

Back Baffle

13.

Hob

14.

Spigot

15.

Hotplate

16.

Front Frame

17.

Back Sealing Plate

18.

Back Sealing Plate Gasket

19.

Door Catch

20.

Window Sealing Tape

21.

Window Glass

22.

Fire Fence

23.

Front Side Brick (2)

24.

Rear Side Brick (2)

25.

Bottom Bricks

26.

Lower Side of Top Baffle

27.

Air Baffle

28.

Inside Back Heat Shield

29.

Door Sealing Rope

30.

Outside Back Heat Shield

31.

Spacers

32.

Optional Pipe Shield

33.

Heat Shield Blanking Plate

34.

Tie Bolts

35.

Top Baffle Plate Gasket

36.

Back Panel Gasket

37.

Side Panel Gaskets

38.

Back Baffle Gasket

39.

Primary Air Duct

40.

Primary and Secondary Air Flap

41.

Cast Iron Spacer

42.

Connecting Rod

43.

Primary Air Control Lever

WATERFORD 100B 90 O.S.A.

WOOD BURNING STOVE

EXPLODED VIEW

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to Comply with July 1990

Particulate Emission Standards

Maximum Heat Output up to 33,000 BTU’s/hr

Heat Output Range 9,000 - 26,700 BTU’s/hr

7

Содержание Fionn 90 o.s.a. and

Страница 1: ...t all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled If this stove is not properly installed a house fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area The stove must be connected to a UL ULC l...

Страница 2: ...EAR VENT REAR FLUE EXIT Fit back sealing plate Part no 17 over the top flue aperture in the hob Part no 13 Fit the flue spigot to part no 11 where part no 17 was making sure that part no 17 and part no 14 are well secured on a bed of fire cement TOP FLUE EXIT Fit part no 14 over top flue aperture in the hob Part No 13 make sure that part no 14 is well secured on a bed of fire cement ASSEMBLY OF OP...

Страница 3: ... or 1 4 6mm thick covered with 1 8 3mm sheet metal is required to cover the area under the heater and to extend to at least 18 450mm at the front and 8 200mm to the sides and rear This will provide pro tection from sparks and embers which may fall out from the door when stoking or fuelling LOCATION There are several conditions to be considered when selecting a location for your Fionn 90 O S A a Di...

Страница 4: ...nts between air vents and outside walls should be sealed to prevent ingress of mois ture l This stove is listed for Mobile home installa tion provided it is properly connected to an outside air supply and a listed chimney with a ceiling support and spark arrester MOBILE HOME INSTALLATION In addition to standard installation instructions the following requirements are mandatory for installation in ...

Страница 5: ...rances may be reduced by the percentage reduction as stated in the wall shield manufacturer s instructions For clearance reduction systems using an air space between the combustible wall and the wall protector adequate air circulation shall be provided by one of the following methods 1 Adequate air circulation may be provided by leaving all edges of the wall protector open with at least a 1 25mm a...

Страница 6: ...o masonry The connector may pass through walls or partitions constructed of combustible material to a masonry chimney provided the connector system selected is installed in accordance with the proper clearances and conditions See figures A B C D page 8 9 6 4 All clearances shall be measured from the outer surface of the combustible material to the nearest point on the surface of the Fionn 90 O S A...

Страница 7: ... Baffle 27 Air Baffle 28 Inside Back Heat Shield 29 Door Sealing Rope 30 Outside Back Heat Shield 31 Spacers 32 Optional Pipe Shield 33 Heat Shield Blanking Plate 34 Tie Bolts 35 Top Baffle Plate Gasket 36 Back Panel Gasket 37 Side Panel Gaskets 38 Back Baffle Gasket 39 Primary Air Duct 40 Primary and Secondary Air Flap 41 Cast Iron Spacer 42 Connecting Rod 43 Primary Air Control Lever WATERFORD 1...

Страница 8: ...e diameter as the chimney connector and having 1 25mm or more of insulation with a min 9 230mm air space between the outer wall of the chimney length and combustibles The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the brick mason ry penetration with non water soluble refrac tory cement Supports should be securel...

Страница 9: ...s less than 2 50mm from the face of the fireplace See Section under Minimum Clearances to Combustibles Before the installation the entire fireplace system should be inspected for condition and code compli ance prior to connecting to the fireplace chimney Older fireplaces and chimneys may not have been constructed to current day codes The fireplace and chimney should be in or brought up to acceptab...

Страница 10: ... your finger when the pipe is cool If you hear a dull echo the pipe may need cleaning Disassemble the chimney connector and clean the sections Replace corroded pipe sections The fit ting of a slip joint in the stove pipe makes the dis mantling easy for cleaning and inspection of chim ney and stove 10 2 Existing fuel fired equipment in the house such as fireplaces or other heating appli ances smell...

Страница 11: ...lean itself when there is sufficient heat generated by burning fuel The Air Way system provides pre heated warm air which keeps the glass clean WARNING DO NOT OPERATE THE STOVE WITH BROKEN GLASS 2 How to Replace a Open the door item 6 and remove the 4 1 4 6 4mm counter sunk screws from the inside Fire Door item 8 and lift it away b Remove the broken glass and gasket take the replacement glass and ...

Страница 12: ...pipe or hot embers or sparks from the chimney FIONN 90 O S A MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDE WALL TO STOVE 20 INCHES 510mm BACK WALL TO CHIMNEY CONNECTOR 18 INCHES 460mm BACK WALL TO STOVE TOP REAR EXIT 141 2 INCHES 370mm CEILING TO HORIZONTAL CONNECTOR 18 INCHES 460mm CORNER 13 INCHES 330mm MANTLE CLEARANCE 25 INCHES 635mm SIDE TRIM 14 INCHES 355mm FLOOR PROTECTION When installin...

Отзывы: