WARNING

DO NOT OBSTRUCT FREE AIR SUPPLY TO THE
AIR INLET DUCT LOCATED AT THE BACK OF
THE STOVE.

OUTSIDE AIR CONNECTION

This stove may be connected direct to the outside of
the house for its combustion air supply.

Note:  It is recommended to use the shortest 
possible outside air supply ducts.  Supply ducts with
long runs, multi bends and corners may reduce air 
volume supply due to excessive drag.

When connecting this stove to an outside air supply
the optional outside air kit must be used, which
includes a spigot, wire mesh, and fixing screws.

a.

Fit the cast iron spigot into the air inlet (Part
No. 39).

b.

Connect a 4” (100mm) stainless steel, gal
vanised ridge or flexible pipe to the air inlet 
spigot.

c.

Fit a 4” (100mm) stainless steel or gal
vanised sweep bend to the outside of the air
supply pipe.

d.

Fit the stainless mesh to the downturn of the
bend terminus using the fixing screws sup
plied with the outside air kit.

e.

Make sure that all joints are secured using 
the fixing screws supplied with the outside 
air kit.

f.

The outside air terminus must be fitted with 
the 1/4” (6mm) x 1/4” (6mm) stainless wire 
mesh to prevent leaves and rodents entering
from the out side.

g.

Air inlets traversing cavity walls should 
include a continuous duct across the cavity.
The duct should be installed in such a man
ner as not to impair the weather  resistance 
of the cavity.

h.

Joints between air vents and outside walls 
should be sealed to prevent ingress of mois
ture.

l.

This stove is listed for Mobile home installa
tion provided it is properly connected to an 
outside air supply and a listed chimney with 
a ceiling support and spark arrester.

MOBILE HOME INSTALLATION

In addition to standard installation instructions the
following requirements are mandatory for installation
in a Mobile Home.

CAUTION:  Do not obstruct combustion air opening.

1.

The stove must be permanently bolted to the
floor of the Mobile Home using the floor 
screws provided.

2.

The stove must have a permanent outside 
air source for combustion.

3.

The stove must be grounded to the steel 
chassis of the Mobile Home.

4.

A listed chimney system, roof thimble, spark
arrestor and roof flashing kit suitable for use
in Mobile Homes must be used.

5.

If the chimney exits the Mobile Home at a 
location other than through the roof, and 
exits at a point 7ft. (2100mm) or less above 
the ground level on which the Mobile Home 
is positioned, a guard or method of enclosing
the chimney shall be fitted at the point of exit
for a height up to 7 ft.(2100mm).

6.

The chimney shall be attached directly to the
room heater and shall extend at least 3 ft. 
(910mm) above the part of the roof through 
which it passes.  The top of the chimney 
should project at least 2 ft. (610mm) above 
the highest elevation  of any part of the 
Mobile Home within 10 ft. (3050mm) of the 
chimney.

4

DO NOT CONNECT TO OR USE IN CONJUNC-
TION WITH ANYAIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH
INSTALLATIONS.

Содержание Fionn 90 o.s.a. and

Страница 1: ...t all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled If this stove is not properly installed a house fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area The stove must be connected to a UL ULC l...

Страница 2: ...EAR VENT REAR FLUE EXIT Fit back sealing plate Part no 17 over the top flue aperture in the hob Part no 13 Fit the flue spigot to part no 11 where part no 17 was making sure that part no 17 and part no 14 are well secured on a bed of fire cement TOP FLUE EXIT Fit part no 14 over top flue aperture in the hob Part No 13 make sure that part no 14 is well secured on a bed of fire cement ASSEMBLY OF OP...

Страница 3: ... or 1 4 6mm thick covered with 1 8 3mm sheet metal is required to cover the area under the heater and to extend to at least 18 450mm at the front and 8 200mm to the sides and rear This will provide pro tection from sparks and embers which may fall out from the door when stoking or fuelling LOCATION There are several conditions to be considered when selecting a location for your Fionn 90 O S A a Di...

Страница 4: ...nts between air vents and outside walls should be sealed to prevent ingress of mois ture l This stove is listed for Mobile home installa tion provided it is properly connected to an outside air supply and a listed chimney with a ceiling support and spark arrester MOBILE HOME INSTALLATION In addition to standard installation instructions the following requirements are mandatory for installation in ...

Страница 5: ...rances may be reduced by the percentage reduction as stated in the wall shield manufacturer s instructions For clearance reduction systems using an air space between the combustible wall and the wall protector adequate air circulation shall be provided by one of the following methods 1 Adequate air circulation may be provided by leaving all edges of the wall protector open with at least a 1 25mm a...

Страница 6: ...o masonry The connector may pass through walls or partitions constructed of combustible material to a masonry chimney provided the connector system selected is installed in accordance with the proper clearances and conditions See figures A B C D page 8 9 6 4 All clearances shall be measured from the outer surface of the combustible material to the nearest point on the surface of the Fionn 90 O S A...

Страница 7: ... Baffle 27 Air Baffle 28 Inside Back Heat Shield 29 Door Sealing Rope 30 Outside Back Heat Shield 31 Spacers 32 Optional Pipe Shield 33 Heat Shield Blanking Plate 34 Tie Bolts 35 Top Baffle Plate Gasket 36 Back Panel Gasket 37 Side Panel Gaskets 38 Back Baffle Gasket 39 Primary Air Duct 40 Primary and Secondary Air Flap 41 Cast Iron Spacer 42 Connecting Rod 43 Primary Air Control Lever WATERFORD 1...

Страница 8: ...e diameter as the chimney connector and having 1 25mm or more of insulation with a min 9 230mm air space between the outer wall of the chimney length and combustibles The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the brick mason ry penetration with non water soluble refrac tory cement Supports should be securel...

Страница 9: ...s less than 2 50mm from the face of the fireplace See Section under Minimum Clearances to Combustibles Before the installation the entire fireplace system should be inspected for condition and code compli ance prior to connecting to the fireplace chimney Older fireplaces and chimneys may not have been constructed to current day codes The fireplace and chimney should be in or brought up to acceptab...

Страница 10: ... your finger when the pipe is cool If you hear a dull echo the pipe may need cleaning Disassemble the chimney connector and clean the sections Replace corroded pipe sections The fit ting of a slip joint in the stove pipe makes the dis mantling easy for cleaning and inspection of chim ney and stove 10 2 Existing fuel fired equipment in the house such as fireplaces or other heating appli ances smell...

Страница 11: ...lean itself when there is sufficient heat generated by burning fuel The Air Way system provides pre heated warm air which keeps the glass clean WARNING DO NOT OPERATE THE STOVE WITH BROKEN GLASS 2 How to Replace a Open the door item 6 and remove the 4 1 4 6 4mm counter sunk screws from the inside Fire Door item 8 and lift it away b Remove the broken glass and gasket take the replacement glass and ...

Страница 12: ...pipe or hot embers or sparks from the chimney FIONN 90 O S A MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDE WALL TO STOVE 20 INCHES 510mm BACK WALL TO CHIMNEY CONNECTOR 18 INCHES 460mm BACK WALL TO STOVE TOP REAR EXIT 141 2 INCHES 370mm CEILING TO HORIZONTAL CONNECTOR 18 INCHES 460mm CORNER 13 INCHES 330mm MANTLE CLEARANCE 25 INCHES 635mm SIDE TRIM 14 INCHES 355mm FLOOR PROTECTION When installin...

Отзывы: