background image

I pg 13

MultiCyclone

WARRANTY

MultiCyclone is covered by a 2 year warranty and 1 year warranty on labour. Commercial 
installations are covered by a 1 year warranty.

Please refer to Waterco’s warranty terms and conditions.

TROUBLESHOOTING GUIDE

Symptoms

Possible Problems / Solutions

Water Is Not Clear

Insufficient disinfectant level.
Incorrect pool chemistry.
Heavy bathing and/ or dirt loads.
Incorrect flow.
Insufficient running times. (Increase pump run time.)
Filter is dirty. (Clean per instructions.)
Hole in filter element.
Air leak on suction line
Pump impeller vanes blocked
Other restrictions include (pool suction cleaners) resistance from other inline 
equipment such as strainers.
Pump not primed.

Low Water Flow

Check strainer baskets for debris.
Check for air leaks on suction side.
Check for restrictions or blockage in either suction or return lines.
System filter needs to be cleaned or replaced.
Pool water level too low.
Pump not primed.
Pump impeller vanes blocked.
Strainer baskets not being used and/ or not being cleaned regularly.
Pump operating under speed (low voltage).

Short Filter Cycles

Presence of algae, check disinfectant content. 
Check pH and total alkalinity. 
Pump output exceeds design flow rate of filter, check pump performance. 
Ineffective cleaning, check conditionsof sediment chamber. 

High Pressure on 
Start Up

Small eyeball fitting in Pool/ Spa.
Partially closed valve on return line.
Too large of pump, check selection.

WINTERISING

Proper winterising procedures should always be taken in order to protect your filter in cold 
climates (temperatures below freezing point).

1.  Switch off the Pump / Close the inlet valve.

2. Open the air release valve and open the purge vale to allow water to flow out of the 

MultiCyclone.

a.  Sand Filter, move the Multi Port Valve handle to the winterise position 

(between filter and waste).

b.  Cartridge Filter, open air release valve.

This will allow air to through to all ports.

3.  Remove any drain plugs from the pump.

4.  Drain water from the pipe work.

Содержание MultiCyclone 12

Страница 1: ...NZ Limited Auckland New Zealand Tel 64 9 525 7570 Waterco C Limited Guangzhou China Tel 8620 3222 2180 Waterco Far East Sdn Bhd Selangor Malaysia Tel 60 3 6145 6000 PT Waterco Indonesia Jakarta Indonesia Tel 62 21 4585 1481 Installation and Operation Manual This equipment must be installed and serviced by a qualified technician Improper installation may result in property damage serious injury or ...

Страница 2: ...arefully read the following instructions 5 The operating safety of the filter is only guaranteed if the installation and operation instructions are correctly followed 6 In the event of defective operation or fault contact Waterco or its nearest authorised service agent 7 To reduce the risk of injury do not permit children to use this product 8 Incorrectly installed equipment may fail causing sever...

Страница 3: ... per year for an average domestic sized swimming pool Minimise Filter Cartridge Cleaning and Replacement The installation of a MultiCyclone as a pre filter to a cartridge filter can reduce filter cartridge cleaning and replacement to once per swimming season and even up to once per year depending on the size of the cartridge filter Air Release Valve MultiCyclone Housing Lid Clear Poly Carbonate Se...

Страница 4: ...he filter so that it is free from flooding away from sumps guttering garden hollows etc 3 Position the filter so that the piping connections purge valve and air release valve is convenient and accessible for operation servicing and winterising 4 Ensure that the compliance label is facing the front to allow easy identification 5 The filter should be placed on a level concrete slab very firm ground ...

Страница 5: ...he MultiCyclone to the next component in line with the filtration system 6 Glue all plumbing to barrel union fittings in accordance with glue solvent manufactures specifications and allow 24 hours to set Ensure glue solvent is not excessively applied to fittings as this could run onto o rings and create sealing problems Note Waterco recommends that a shut off valve be installed after the MultiCycl...

Страница 6: ...cur if air release valve becomes loose MULTICYCLONE FILTER MAINTENANCE The MultiCyclone Plus filter maintenance is determined by the following conditions 1 The sediment chamber is half filled with sediment This accumulation of sediment can be visibly monitored through the MultiCyclone clear sediment chamber The MultiCyclone is cleaned by simply opening the purge valve Only 15 litres 4 gallons of w...

Страница 7: ...nt chamber of trapped sediment Once the sediment chamber is clean open the 2 way valve and then close the purge valve GENERAL MAINTENANCE GUIDE To ensure the maximum life of the MultiCyclone please follow the procedures below 1 Visually monitor through the MultiCyclone clear sediment chamber Clean sediment chamber when accumulated sediment is half full 2 Maintain a correct chemical balance of your...

Страница 8: ...placed Pool water level too low Pump not primed Pump impeller vanes blocked Strainer baskets not being used and or not being cleaned regularly Pump operating under speed low voltage Short Filter Cycles Presence of algae check disinfectant content Check pH and total alkalinity Pump output exceeds design flow rate of filter check pump performance Ineffective cleaning check conditionsof sediment cham...

Отзывы: