2.5 INSTALL HYDROXZONE SUPPLY TUBE
2.5.1. The Hydroxzone unit is supplied with sufficient braided supply tube which may be
cut to length. Ensure sufficient slack in the supply tube. Do not extend the length of
the braided supply tube.
2.5.2. For installations where the Hydroxzone unit is installed 400mm above the highest
point of the filter system, cut the polybraided line to a minimum of 600mm from
the Hydroxzone unit and install the check valve with the concave shape facing the
direction of the Venturi Injector, (Make sure you can blow air through the Check
Valve towards the Injector port). See Figures 2.4.
2.5.3. Cut a 150mm length of ¼” polybraided hose and connect one end to the open
ozone suction point (As shown in illustration 2.5) on the Venturi Injector and the
other end to the OUTLET side of the Check Valve.
2.4 Check Valve Orientation
Ozone
Flow
Direction
Concave
Shape
2.5 Ozone Inlet point at venturi injector
Outlet