IMPORTANT SAFETY INSTRUCTIONS

When installing and using electrical equipment, basic safety precautions should always be 
followed. This includes the following:

READ AND FOLLOW ALL INSTRUCTIONS

Do not block the pump suction; this can cause severe or fatal injury if blocked with the 
body.

To reduce the risk of injury, do not permit children to use this product unless they are closely 
supervised at all times.

Risk of Electric Shock: connect only to a grounding type receptacle protected by a residual 

current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle 

is protected by an RCD.

Do not bury the electrical cable. Locate the cable in a manner that minimises abuse from lawn 
mowers, hedge trimmers, and other equipment.

To reduce the risk of electric shock, replace damaged cable immediately.

 

Incorrectly installed equipment may fail, causing severe injury or property damage.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

!

DANGER

Equipment that is incorrectly pressure tested may fail, causing severe injury or property 
damage. Pressure testing should only be conducted by trained pool professionals.

Do not change the multiport valve position when the pump is running.

 

This pump is for use with permanently installed pools and may also be used with hot tubs 
and spas if so marked. Do not use with storable pools. A permanently installed pool is 
constructed in or on the ground or in a building such that it cannot readily be disassembled 
for storage. A storable pool is constructed so that it may be readily disassembled for storage 
and reassembled to its original integrity and has a maximum dimension of 18 feet (5.49m) and 
a maximum wall height of 42 inches (1.07m).

    
 

To prevent overheating, do not install the pump within an enclosed area unless adequate 
ventilation is provided.

Do not start the pump dry! Running the pump dry for any length of time will cause severe 
damage and will void the warranty.

Chemical fumes and spills can weaken pool/spa equipment. Corrosion can cause pumps, 

filters and other equipment to fail, resulting in severe injury or property damage. Do not store 

pool chemicals near your equipment.

READ AND FOLLOW ALL INSTRUCTIONS

WARNING

!

WARNING

!

WARNING

!

!

CAUTION

!

CAUTION

!

CAUTION

Waterco Commercial Pump

Содержание HYDROSTAR MK3

Страница 1: ...Sdn Bhd Selangor Malaysia Tel 60 3 6145 6000 PT Waterco Indonesia Jakarta Indonesia Tel 62 21 4585 1481 W99245 03 2009 www waterco com WARNING COMMERCIAL PUMP Owners Manual Installation and Operation...

Страница 2: ...P 09 Start up procedure 09 MAINTENANCE 10 Strainer Basket Cleaning 10 Winterizing 11 Electric Motor Care 12 TROUBLESHOOTING 13 HYDROSTAR MK3 14 Pump Performance Curves Dimensional Drawings HYDROSTEEL...

Страница 3: ...severe injury or property damage Pressure testing should only be conducted by trained pool professionals Do not change the multiport valve position when the pump is running This pump is for use with p...

Страница 4: ...will cause the wet end to crack In these scenarios place the lifting strap under the pump housing Lifting Procedure i Raise the pump slowly to ensure that the chains or straps will not slip when under...

Страница 5: ...RNING RISK OF ELECTRIC SHOCK Three Phase Connections Three phase connections should be installed as follows a Hydrostar Mk3 WYE STAR CONNECTION for export market DELTA CONNECTION for Aus NZ market b H...

Страница 6: ...above 4 C 39 2 F and not exceeding 40 C 104 F Please refer to the Waterco Warranty Terms and Conditions booklet supplied with the pump Start up procedure a Clear all piping of construction debris and...

Страница 7: ...this point have been followed check for suction leaks and repeat steps h through o WARNING DO NOT open the strainer pot if the pump fails to prime or if the pump has been operating without water in th...

Страница 8: ...urn pump shaff should spin freely If not contact electrician or nearest Waterco Limited branch for service 3 LOW FLOW Dirty lter Backwash or clean cartridge Dirty Skimmer and Pump strainer Clean skimm...

Страница 9: ...1000 1200 1400 Flow m3 hr 0 12 24 36 48 60 72 84 Hydrostar Mk3 Performance Curves Pump dimensional drawings Hydrosteel Pump Performance Chart Flow lpm 0 200 400 600 800 1000 1200 1400 1600 1800 Flow...

Страница 10: ...88 Dimensions all in mm Waterco Commercial Pump Flow lpm 0 500 1000 1500 2000 2500 Flow m3 hr 0 30 60 90 120 150 CAST IRON PUMP Pump performance curves Pump dimensional drawings WARRANTY WARNING Water...

Отзывы: