To ensure your safety and the adequate functioning of your heat pump, 

all electrical work 

should  be  performed  by  a  fully  qualified  and  licensed  electrician  in  accordance  with 

local electrical codes.

An adequate circuit breaker and copper wiring must be used. Refer to the electrical installation 
diagram  found  on  the  inside  of  the  access  panel.  It  may  be  necessary  to  install  a  ground 
circuit breaker.

!

VITAL

GENERAL SAFETY INSTRUCTIONS

DO NOT STOP WATER FLOW TO THE HEATER FOR MORE THAN 8 HOURS WITHOUT 

DRAINING IT.

WARNING

!

IMPORTANT

DEFROSTING IN LOW AMBIENT AIR TEMPERATURE CAN PROVIDE THE FORMATION 

OF ICE AROUND THE HEAT PUMP.

WARNING

!

MAKE SURE THE INSTALLATION IS DONE ACCORDING TO THE INSTRUCTIONS OF THIS 

MANUAL. SEE “INSTALLATION” SECTION.

MAKE SURE YOUR HEATER WAS PROPERLY GROUNDED AND BONDED. SEE “BONDING” 

AND “BONDING DIAGRAM” SECTIONS IN THE GENERAL OWNER MANUAL .

THE UNIT MUST BE DISCONNECTED BEFORE OPENING THE ACCESS PANEL.

WARNING

!

The power cable ground must be connected to the electrical panel and to the ground 

lug of the heat pump. An improper installation may be a potential cause of fire, electrical 

shock or injury.

WARNING

!

Содержание ElectroheatSubZero

Страница 1: ... installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment ...

Страница 2: ...PERATION OF YOUR POOL HEATER 04 Operation of Multifunction Electronic Control Panel 04 To start up the unit 04 To stop the unit 04 To raise or lower desired water temperature 04 Defrost cycle SubZero 05 To select Pool or Spa mode 05 Automatic Pool or Spa Mode and Remote Control 05 Winterizing 06 Service Analyser Codes 07 ...

Страница 3: ...kly defrost the evaporator even when the temperature in the air is closed to freezing point This defrost cycle is not possible with standard machine since it is only carried out by ventilation system It is strongly recommended to install a solar blanket on the swimming pool when the temperature of the ambiant air is between 0 and 12 degres Celcius in order to limit heat loss through evaporation It...

Страница 4: ...ATER FOR MORE THAN 8 HOURS WITHOUT DRAINING IT WARNING IMPORTANT DEFROSTING IN LOW AMBIENT AIR TEMPERATURE CAN PROVIDE THE FORMATION OF ICE AROUND THE HEAT PUMP WARNING MAKE SURE THE INSTALLATION IS DONE ACCORDING TO THE INSTRUCTIONS OF THIS MANUAL SEE INSTALLATION SECTION MAKE SURE YOUR HEATER WAS PROPERLY GROUNDED AND BONDED SEE BONDING AND BONDING DIAGRAM SECTIONS IN THE GENERAL OWNER MANUAL TH...

Страница 5: ... width by 5 inches in depth The base should be completely isolated from the building foundation or wall to prevent the possibility of sound or vibration transmission into the building The size of the base should not be less than the base of the pool heater Your Heat Pump will accumulate condensed water approx 1 to 1 5 Gallons or 4 to 6 Litres per hour therefore causing water to drain out of the un...

Страница 6: ...ff the electrical power supply or by programming the desired water temperature below actual pool water temperature The unit will be OFF if the temperature set point is below 15 C The display indicates OFF To raise or lower desired water temperature Pool or Spa mode Push the SET key until you see POL or SPA Press the UP or DOWN arrow only once and the programmed temperature is displayed Press the U...

Страница 7: ...the Spa temperature to maximum 40 C and the Pool setting to OFF so that when the remote control calls for heat it will activate the Spa mode and start the heater Contact us for more details on this feature Defrost Cycle SubZero The interval time between the defrost cycle depends on the temperature of the ambient air and of the humidity During the defrost cycle the ventilator stops functioning and ...

Страница 8: ...nside of the heat exchanger with a garden hose and to drain the unit once more With the help of pool return winter plugs block the water Inlet and Outlet connections to prevent access by vermin DO NOT leave the water piping connected to the unit for the winter It is also possible to fill the heat exchanger with pool anti freeze only but ensure that the anti freeze contains an elevated pH to preven...

Страница 9: ...ater temperature probe is open or defective Verify connections FLO FL3 Possible causes FIL parameter must be set to activate pool pump The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool pump Water pressure switch must be adjusted or it is defective The unit is in the protection mode and will show FL3 press any key to restart the unit FI3 cod...

Страница 10: ...76 OFFICES OVERSEAS Waterco USA Augusta USA Tel 1 706 793 7291 Waterco Canada St Hyacinthe QC Canada Tel 1 450 796 1421 Waterco Europe Limited Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco NZ Limited Auckland New Zealand Tel 64 9 525 7570 Waterco C Limited Guangzhou China Tel 8620 3222 2180 Waterco Far East Sdn Bhd Selangor Malaysia Tel 60 3 6145 6000 PT Waterco Indonesia Jakarta Indonesia T...