Waterco Commandomatic
Volumatic
(with flow meter)
The unit keeps track of how much water has been processed since the last regeneration and automatically
regenerates once the remaining capacity is less than the daily reserve capacity. However if the calendar override
is set and if the number of days is equal or greater than the calendar setting, regeneration will be initiated at the
regeneration time.
Calendar Timer
(no flow meter)
The units keep track of the length of time since the last regeneration/ backwash and automatically regenerates /
backwash once the programmed calendar setting has been reached.
COMMANDOMATIC AUTOMATIC CONTROLLER
The
Commandomatic Automatic Controller
fitted to your Commandomatic unit is a programmable
microprocessor. There is the option of either the Volumatic or the Calendar Timer.
PROGRAMMING THE CONTROLLER
Plug in the supplied power pack and connect the power pack to the Commandomatic Controller. The capacity
display will be shown as below, with the timer initiated.
UP, DOWN, SELECT and MANUAL keys.
Operation of the menus and settings are accessed with the UP/ DOWN and SELECT keys.
A)
UP/ DOWN
- These buttons are used to move through the numerous displays in either service mode
or running mode and to increase or decrease values. When holding down one of the buttons, a slow
stepping action begins which after five seconds switches to fast stepping.
B)
SELECT
- This button is used to allow the setting of shown values in a display during service mode.
The first press changes to an editing mode, a value will flash on the display, and this value can be
modified using the UP/ DOWN buttons. The second press advances to the next value on the display.
When the last value on the display has been modified, pressing the SELECT button will exit editing mode
and advance automatically to the next display. The value in the next display can be modified simply be
repeating the process by pressing the SELECT again.
C)
MANUAL
- This button is used for manual regeneration/ backwashing and for the initial filling of
the unit.
Calendar Timer - Softener / Purifier
1. Press SELECT to enter the Access Code display.
2. Enter the Access Code
1357
via the
UP
button. After each input press SELECT and the number will convert to an
Asterix (*), once all the numbers are entered, press SELECT to exit and the Display will revert to the default display.
3. Scroll to “
Set Time
”, press SELECT and set the current time.
4. Scroll to “
Calendar Override
” press SELECT and set the number of days in between regenerations.
This is determined by the amount of water being used and the level of hardness; please refer to the “
Softener
and Softener/ Purifier Regeneration
”.
5. Scroll to “
Regeneration Time
”, the default setting is at 2:00am, if you wish to change this setting, press
Select
and input the new regeneration time.
6. Scroll to “
Regeneration Period
”, press SELECT and input the appropriate regeneration period
according the table below:
7. Scroll to “
Set Salt Warning
”, press
Select
and set the salt warning according to the table below:
Volumatic Controller - Softener/ Purifier
1. Press SELECT to enter the Access Code display.
2. Enter the Access Code
8624
via the
UP
button. After each input press SELECT and the number will convert to an
Asterix (*), once all the numbers are entered, press SELECT to exit and the Display will revert to the default display.
3. Scroll to “
Set Time
”, press SELECT and set the current time.
4. Scroll to “
Calendar Override
” you can either leave the setting at its default setting of
99 days
or press SELECT
and set the maximum number of days in between regenerations. The Volumatic will regenerate based on volume,
but if the number of days is equal or greater than the calendar setting, a regeneration will be initiated.
5. Scroll to “
Regeneration Time
”, the default setting is at 2:00am, if you wish to change this setting,
press Select and input the new regeneration time.
6. Scroll to “
Regeneration Period
”, press SELECT and input the appropriate regeneration period
according the table below:
7. Scroll to “
Set Capacity
”, press SELECT and input the appropriate capacity according to the table below:
8. Scroll to “
Set Hardness
”, press SELECT and input the hardness of your water in milligrams per litre.
The hardness of the water supply can be obtained from your local Water Authority.
9. Scroll to “
Set Salt Warning
”, press SELECT and set the salt warning according to the table below:
After programming and installation.
Once the unit is installed activate battery-backed memory, by removing the tab shown in the photo.
Unit Model No.
W7 / WPS4
PS9 / S14
Regeneration Time
60 mins
80 mins
Unit Model No.
W7 / WPS4
PS9 / S14
Salt Warning
10 Regenerations
7 Regenerations
Unit Model No.
W7 / WPS4
PS9 / S14
Regeneration Time
60 mins
80 mins
Unit Model No.
W7
WPS4
S14
PS9
Capacity
975 000mg
650 000mg
1950 000mg
1300 000mg
Unit Model No.
W7 / WPS4
PS9 / S14
Salt Warning
10 Regenerations
7 Regenerations
I