Waterco 20 SC Скачать руководство пользователя страница 9

I pg 07

Waterco Hydrochlor®

Note:

 When the LED lights flash it is an indication of:

•  Low salt level
•  Low temperature or 
•  Cell plates wearing

If you don’t know what your salt level is or how to test it, consult your local pool care specialist.

Water Chemistry

It is important to maintain the correct water chemical balance in the swimming pool; this will help 
protect the Electrochlor chlorinator unit and its cell.

Consult the local pool professional for the correct water balance according to the swimming pool 
type.

The Electrochlor chlorinator will run correctly at the following chemistry levels

Range

Suggested

pH.                                     

7.2 – 7.8                      

7.2 – 7.6

Total alkalinity                     

60 – 200ppm                 

80 – 150ppm

Calcium hardness                

100 – 500ppm               

60 – 250ppm

Stabilizer (Sun screen)        

30 – 60ppm

SALT CELL CLEANING PROCEDURE 

a.  Press the MODE key until OFF on the power pack, then turn the pump and 

Hydrochlor to standby mode.

b.  Unscrew the barrel unions from the salt cell and disconnect the cables 

from the salt cell’s brass connectors.

c.  Turn the salt cell housing upside down with both ports facing upwards.

d.  Pour the Cell Wash cleaning solution into the housing to dissolve the calcium build-up from the 

salt cell plates. There should be just enough solution to cover the salt cell plates. 

e.  Allow enough time for the solution to dissolve the calcium build-up from the salt cell plates. 

Approximately 5 to 10 minutes.

f.  Once the calcium build-up has been removed, pour out the Cell Wash solution into a bucket and 

lightly rinse-off excess calcium and Cell Wash solution from the salt cell assembly, with fresh 
water.

g.  Reconnect the salt cell onto the filter system

h.  Press the 

MODE

 button to AUTO  or ON  on the power pack to reactivate the Hydrochlor.

 

Never use products that are not specifically manufactured to clean the Hydrochlor®’s salt 
cell. Do not use raw acids such as Hydrochloric acid. This will damage the salt cell and 
severely shortens its life and will void warranty. Please consult your local pool professional 
for advice on salt cell cleaning products.

Содержание 20 SC

Страница 1: ...tallation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Rainbow Pool Products PO Box 2388 Mansfield Qld 4122 Telephone STD 61 7 3849 5385 Facsimile STD 61 7 3849 5384 Email info rainbowpoolproducts com au Web www rainbowpoolproducts com au ...

Страница 2: ...ting the Hydrochlor s 04 Self cleaning Cell EZY TIMER SETTING 05 Setting a New Time 05 Setting the Timer 05 Timer Default Settings 05 Overnight Operation 06 CHLORINE PRODUCTION LEVEL 06 CHLORINATOR OVERRIDE SWITCH 06 PUMP PROTECTION 06 WATER CHEMISTRY 06 Salt Level 06 Water Chemistry 07 SALT CELL CLEANING PROCEDURE 07 TROUBLESHOOTING 08 TECHNICAL SPECIFICATIONS 08 GENERAL SAFETY RULES 09 WARRANTY ...

Страница 3: ... separated into its basic components chlorine and sodium The chlorine is instantaneously transformed into Hypochlorous acid this the chlorine form that kills algae and other harmful organism in the water A chlorine generator s main function is to produce chlorine for the pool This keeps a residual of chlorine in the pool that prevents algae from growing The chlorine then turns back into salt and t...

Страница 4: ...s for the current time of the day or Timer Settings Subsequent presses will change the minutes immediately WINTER By selecting WINTER hours of operation will be reduced to save energy during the winter months Deselecting WINTER will instantly return to increased hours of operation for the non winter months AUTO operation SUPER CL Superchlorination If the SUPER CL key is pressed once the Hydrochlor...

Страница 5: ...reversing of polarity or electrical potential difference will then start to remove any calcium build up which may have been deposited onto the cathode This continuous reversing of polarity will keep the cell clean from calcium deposits during its operation providing the chemical balance and flow of the pool water thru the cell is maintained within normal parameters It is recommended that you obtai...

Страница 6: ...ted in areas where chemicals are stored e g acid and chlorine Also ensure that the Hydrochlor Power Pack can be connected to the mains power outlet of the pool area Note that this outlet must meet the current applicable local standards at the time of installation Installing Connecting the Hydrochlor Self Cleaning Cell The Cell Housing assembly should be plumbed into the pool return line after all ...

Страница 7: ...efault Settings A new Hydrochlor initially has been set with the following defaults timers SUMMER Timer 1 START 8 00 Timer 1 FINISH 12 00 Timer 2 START 16 00 Timer 2 FINISH 20 00 WINTER Timer 1 START 9 00 Timer 1 FINISH 11 00 Timer 2 START 17 00 Timer 2 FINISH 19 00 All time settings can be individually programmed however altering the SUMMER times will automatically change the matching WINTER time...

Страница 8: ...set at maximum it will turn to zero and each press will raise production by one LED till MAX If the pool water is over chlorinated simply reduce the chlorine production set level CHLORINATOR OVERRIDE SWITCH Normal operation is O To start override switch to to initiate override function of stopping pump for backwashing vacuuming the pool to waste and lowering the pool water level Press Mode button ...

Страница 9: ... salt cell and disconnect the cables from the salt cell s brass connectors c Turn the salt cell housing upside down with both ports facing upwards d Pour the Cell Wash cleaning solution into the housing to dissolve the calcium build up from the salt cell plates There should be just enough solution to cover the salt cell plates e Allow enough time for the solution to dissolve the calcium build up f...

Страница 10: ...at this will require reset after blackout Electrical fault Return to distributor for repair TECHNICAL SPECIFICATIONS Model Input Watt kW max Output current DC A max Chlorine Production g hr Max Pool Capacity L Climate Temperate Tropical 20 SC 290 20 20 80 000 48 000 25 SC 330 25 25 100 000 60 000 30 SC 380 30 30 120 000 72 000 Model 20 SC 25 SC 30 SC Primary Input Volts Frequency Hz 220 240 50 60 ...

Страница 11: ...horized persons and that these persons have first carefully read the Service and Installation Instructions 8 The operating safety of the chlorinator is only guaranteed if the Installation and Service instructions are correctly followed 9 The limit values stated in the Technical Specifications should not be exceeded under any circumstance 10 In the event of defective operation or fault contact the ...

Страница 12: ...9 33 30 WATERCO USA INC Augusta Georgia USA Tel 1 706 793 7291 WATERCO CANADA Longueuil Quebec Canada Tel 1 450 748 1421 WATERCO NZ LIMITED Auckland New Zealand Tel 64 9 525 7570 WATERCO LIMITED Guangzhou China Tel 86 20 3222 2180 WATERCO FAR EAST SDN BHD Selangor Malaysia Tel 60 3 6145 6000 PT WATERCO INDONESIA Jakarta Indonesia Tel 62 21 4585 1481 WATERCO SINGAPORE INTL PTE LTD Nehsons Building ...

Отзывы: