ENG 9
Functions of the Main Components
The standard configuration of the water purifier that utilizes the current,
most advanced international RO technology is as follows:
•
The first stage is a 10-inch 5-micron PP filter (Sediment):
The pores on the aperture within the PP filter is 5 microns wide so it
can effectively filter rust, sand, other larger particles and solid impurities
suspended in the water.
•
The second stage is a 10-inch 85C granular activated carbon filter:
The filter effectively absorbs chlorine, mould, disinfection by-products,
odors, discolorations and other materials suspended in the water.
•
The third stage is a 10-inch CTO block carbon:
This filter further removes small particles within in the water, suspended
solids, colloids, etc.
•
The Fourth stage is the RO membrane:
The membrane has an aperture of 0.0001 micron (0.1 nm) that reduces
bacteria by 4,000 fold, reduces viruses by over 200 fold, so you can
effectively remove bacteria, viruses, heavy metals, pesticide residue,
and other harmful substances contained in your water supply .
•
The fifth-stage is a post-activated carbon filter:
This filter regulates the taste of water an d keeps the water fresh .
Note: This machine also has an optional configuration
which is as follows:
Pretreatment Filter: KDF two stage filter, KDF three stage filter, sintered
activated carbon filter Post-filter: Alkaline filter, infrared mineralization
activated carbon filter, alkaline sterilization filter, sterilizing filter.
Technical Specifications
Note: the parameters above may change due to product improvements, but the product name plate shall remain the same. TDS refers to influent total dissolved solids.
Model No.
Voltage
Suitable Water Pressure
Operating Pressure
Inlet Temperature
Maximum Daily Water TDS Value
Flushing Method
Electric Shock Protection Type
Suitable Water Quality
Power Rating
Maximum Daily Water Production Volume
AC 220V 50HZ
28.8 W
0.1 ~ 0.35 MPa
0.4 ~ 0.6 MPa
5 ~38
˚
C
≤1000 PPM
Auto Flushing
75 Gallons, approximately 283 Liters
Type II
Munical tap water meeting the GB5749-2006 standarts
LAL-267 NP
LAL-267 WP
Note:
0.1 MPa = 1.02 Kg/cm
2
= 14.5Psi
1 Psi = 0.07 Kg/cm
2
1 Gallon = 3.785 Liters
75 GPD = 75 Gallons/Day = 284 Liters/Day = 197 Milliliters/Minute
Dimensions
Weight
370 x 480 x 170 mm
12.5 kg
17.5 kg
Содержание LAL-267
Страница 1: ...Innovation has a name LAL 267 Reverse Osmosis User Manual Ters Osmoz Kullanma K lavuzu...
Страница 2: ......
Страница 4: ...ENG 2 CONTENTS NDEK LER...
Страница 20: ...TR 18...
Страница 43: ...TR 41 NOTE...
Страница 44: ...TR 42 NOTE...
Страница 45: ...TR 43 NOTE...
Страница 46: ...TR 44 NOTE...
Страница 47: ......