FLUSHING OF SYSTEM:

To flush the system of any debris and air after installation is complete, please perform the following steps:

 

1 . Rotate bypass handles to the bypass mode 

(see Fig. 2 of page 4)

 .

 

2 . Turn on inlet water and check for leaks in the newly installed plumbing .

 

3 . Fully open a cold water faucet, preferable at a laundry sink or bathtub without an aerator .

 

4 .  Allow water to run until clear to rid pipes of debris which may have occurred during installation .

 

System regeneration sequence is in the following order . (If it is desired to change this sequence, please refer to the Dealer 

Master Programming Guide or contact the manufacturer .)
 

1) BACKWASH 

4) BRINE TANK FILL

 

2) BRINE and RINSE DOWN 

5) END (returns to Standby)

 

3) RAPID RINSE 

The system is now ready for filling with water and for testing .

1 .   With the softener in the bypass mode 

(Fig. 2 on page 4)

 and the control valve in normal operation where the display 

shows either the time of day or the gallons remaining, manually add 8” of water to the regenerant tank .

NOTE:

 If too much water is put into the brine tank during softener start up, it could result in a “salty water” complaint after 

the first regeneration .
 During the first regeneration the unit will draw out the initial volume of brine/regenerant and refill it with the correct preset amount .

2 .   With the softener in bypass mode, press and hold the 

regen

 button until the motor starts . Release button . The display will read 

“Pend 0” for about three seconds while the system transfers from one tank to another . After the transfer is complete, the valve will 

automatically advance to the “Backwash” position . Once the valve has stopped in this position, unplug the transformer so that 

the valve will not cycle to the next position . Open the inlet handle of the bypass valve very slightly, allowing water to fill the tank 

slowly in order to expel air from the tank .

CAUTION:

  If water flows too rapidly, there will be a loss of media to the drain.

3 .  When the water is flowing steadily to the drain, clear and without the presence of air, slowly open the inlet valve . Restore 

power and momentarily press the 

regen

 button to advance the control to the “BRINE” position .

4 .  With the bypass now in diagnostic mode 

(Fig. 3 on page 4)

, check to verify that water is being drawn from regenerant tank 

with no air leaks or bubbles in the brine line . There should be a slow flow to the drain . Disconnect brine line from the safety float 

valve in the brine tank and check for a vacuum . After proper confirmation, reconnect brine line, making sure to tighten securely .

5 .  Momentarily press 

regen

 again until the display reads “RINSE .” There should be a rapid flow to the drain . Unplug transformer 

to keep the valve in the “RINSE” position . Allow to run until steady, clear and without air . While the unit is rinsing, load the 

brine tank with water softener salt 

(refer to page 10, Brine Tank Maintenance and Salt)

 . Restore power .

6 .   Push 

regen

 again and the unit will advance to the “Brine Refill” position . Check to make sure the brine tank is refilling .  

The flow rate is usually  .5 gpm for all residential and light commercial applications .

7 . Push 

next

 and the unit will return to normal operation .

8 .  Place unit into bypass mode again 

(see Fig. 2 on page 4)

 and press and hold the regen button to allow control valve to 

transfer to the second tank . Follow steps 2-7 to now expel air from this tank .

9 .  When finished expelling air from second tank, return bypass handles to normal operating position 

(see Fig. 1 on page 4)

 . 

The unit is now online and soft water is available for use .

10 . 

 CONDITIONING OF MEDIA 

(To flush any remaining debris and air from the system): 

1 . Fully open a cold water faucet, preferably at a laundry sink or bathtub without an aerator . 

2 . Wait two to three minutes or until water runs clear, then turn water off . 

3 . Turn on hot water and check for air, then turn water off after air is discharged .

11 .  

SANITIZING OF UNIT UPON INSTALLATION AND AFTER SERVICE 

(At this time, it is advised to sanitize the softener): 

1 . Open brine tank and remove brine well cover .  

2 . Pour 1 oz . of household bleach into the softener brine well .  

3 . Replace brine well cover . 

NOTE: 

Avoid pouring bleach directly onto the safety float components in the brine well . 

    Unit sanitizing will be complete when the first cycle is run and the bleach is flushed from the softener .

12 . Check time of day . Start-up is now complete .

START-UP INSTRUCTIONS:

Содержание Evolve EV1-1044TW

Страница 1: ...Evolve Series Twin Water Softeners and Conditioners For Models EV1 TW EV2 TW EVR TW EVRC TW EVRS TW EVRCS TW...

Страница 2: ...Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner co...

Страница 3: ...tallation are in compliance with all state and local laws and regulations For the homeowner please read Programming Procedures and Operating Displays and Instructions During operation the normal user...

Страница 4: ...egeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is isola...

Страница 5: ...ns only electrical 115 120V 60Hz uninterrupted outlet the tank should be on a firm level surface 1 The distance between the drain and the water conditioner should be as short as possible 2 Since salt...

Страница 6: ...op at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti siphon trap Piping the drain line overhead...

Страница 7: ...ill be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration...

Страница 8: ...STEP 7 ALARM BUZZER The manufacturer has factory set ON as the default An alarm will sound at the indicated time after a regeneration if there is no salt or if another error has occurred Turn the ala...

Страница 9: ...d minimum of 50 gallons the unit will automatically regenerate that night and resume normal operation CAUTION Depending on the severity of water conditions and the length of no water usage it may not...

Страница 10: ...turned on alerting you to these conditions To turn off alarm If the audible alarm sounds due to a low salt condition press any button on the face of the control valve to turn off If salt is not added...

Страница 11: ...arily press the regen button to advance the control to the BRINE position 4 With the bypass now in diagnostic mode Fig 3 on page 4 check to verify that water is being drawn from regenerant tank with n...

Страница 12: ...er to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin con...

Страница 13: ...ing in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type and piston type mix m...

Страница 14: ...h piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Pres...

Страница 15: ...A Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper set...

Страница 16: ...ap assemblies on both sides of the valve 8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor transfer cap from the control valve the cap will spri...

Страница 17: ...ult in damaging the cable 17 Position the large white drive gear with the A pointing toward the one o clock position and then press it onto the stainless steel drive shaft making sure it snaps and loc...

Страница 18: ...acket spring clip 1 4 CV3502WE Evolve PC board used on chlorine generator models 1 CV4022WU Evolve PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assemb...

Страница 19: ...Item No Part No Description Qty 1 CV3005 1 spacer stack assembly 1 2 CV3004 Drive cap assembly 1 3 CV3135 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 5 CV31...

Страница 20: ...20 REPLACEMENT PARTS See pages 22 23...

Страница 21: ...01 T1 transfer drive cap assembly 1 15 CV4011 01 T1 transfer drive gear assembly 1 16 CV4012 T1 transfer drive gear axle 1 17 CV4013 T1 transfer reduction gear 1 18 CV3264 WS2H bypass reduction gear a...

Страница 22: ...y light green not shown CV3170 O ring 011 lower not shown CV3171 O ring 013 upper The injector plug and the injector each use one lower and one upper o ring REPLACEMENT PARTS OPTIONAL CHLORINE GENERAT...

Страница 23: ...CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3 4 e...

Страница 24: ...METER PLUG Item No Part No Description Qty 1 CV3151 Nut 1 QC 1 2 CV3003 Meter assembly includes items 3 4 1 3 CV3118 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 REPL...

Страница 25: ...T s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4640 32 474 float assembly 32 w 2 grommets 1 8 CH4600 50 474 safety brine valve w 5 gpm glow control 1 9 CH7016...

Страница 26: ...he valve the Service Wrench shown in various positions on the valve is available to aid in assembly or disassembly SERVICE WRENCH CV3193 02 IN OUT HEAD FOR TANK B Item No Part No Description Qty CD140...

Страница 27: ...Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O...

Страница 28: ...TANKS Item No Part No Description Qty CV4052 01 Interconnect kit for tanks 12 and larger 1 1 CV3151 Nut 1 QC 4 2 CV3150 Split ring 4 3 CV3105 O ring 215 4 4 CV3352 1 1 4 1 1 2 PVC solvent fitting 4 5...

Страница 29: ...Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2...

Страница 30: ...1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 N...

Страница 31: ...400 6 1 28 300 9 5 11 100 3 2 22 900 6 1 28 200 9 3 Amount of Media Cu Ft 1 0 1 5 2 5 1 0 1 5 2 5 Maximum Water Hardness GPG 20 30 40 40 60 80 2 Maximum Iron and Manganese PPM 8 0 10 0 15 0 8 0 10 0...

Страница 32: ...mum 15 600 3 0 23 600 6 0 35 400 9 0 53 000 12 0 60 000 18 0 80 000 24 0 Amount of Resin Media Cu Ft 85 1 0 1 5 2 5 3 4 Maximum Water Hardness GPG 50 75 100 100 100 100 2 Minimum pH Required 7 0 7 0 7...

Страница 33: ...ts expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condi...

Страница 34: ...ATION When the system is operating one of six displays will be shown 1 time of day gpm 2 flow rate 3 vacation mode 4 capacity remaining 5 days to a regen 6 dealer name and phone number Pressing next w...

Страница 35: ...th and buttons Default is OFF 9 Press next 10 Turn service alarm by time ON with and buttons Default is OFF 11 Press next three times 12 Turn alarm buzzer ON or OFF with and buttons 13 Press next 14 A...

Страница 36: ...Manufactured exclusively for Evolve Series Dealers at 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2014 Evolve Series All rights reserved LIT EV TW MAN 2 17...

Отзывы: