background image

8

 PROGRAMMING PROCEDURES:

1

DAYS BETWEEN REGEN

SET

 OFF

3

WATER HARDNESS

SET

20

2

REGEN IMMEDIATE

GAL

GR

ON ZERO

4

LIGHT NORMALLY

SET

ON

8

Return to general display.

5

6

7

SERVICE ALARM 

SET

OFF

SERVICE ALARM 

SET

OFF

  YR

GAL

ALARM BUZZER START

SET

ALARM BUZZER END

SET

6:00

AM

10:00

PM

ALARM BUZZER

SET

ON

Typically, time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended 

power outage occurs, the time of day will flash on and off indicating that the time should be reset. To set the clock:

STEP 1 –

 Press the 

CLOCK

 button.

STEP 2 –

  Set the hour of the day using 

+

 or 

 buttons. AM/PM toggles after 12. Press 

NEXT 

to go to step 3.

STEP 3 –

   Set the minutes using 

+

 or 

 buttons. Press 

NEXT

 to go to step 4 or 

REGEN

 to return to previous step. 

STEP 4 –

  Set the day of the week using 

+

 or 

 buttons. Press 

NEXT

 to exit clock setting or 

REGEN

 to return to previous step. 

1. Set Time of Day

1

TIME

HOUR

AM

SET

2:00

TIME

MINUTES

AM

SET

2:00

2

3

CURRENT DAY

SET

MON

4

Return to general display.

The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated 

after the hardness is entered. Press 

NEXT

 to cycle to the next step or 

REGEN

 to return to the previous step. 

STEP 1

 – Press and hold the 

NEXT

 and 

+

 buttons simultaneously for 3 seconds.

STEP 2

 –  

HARDNESS: 

Use the 

+

 or 

 buttons to adjust the hardness value in grains per gallons. Adjustable 

from 1 to 150 gpg in 1 grain increments (default setting is 20).

The hardness value is based on the actual compensated hardness of the water and must be set by 

an authorized dealer following an on-site water analysis. Adjusting the number will only impact the 

frequency of regeneration and will not alter or affect the hardness of the water treated by the unit. 

Note: If a resin media is used, increase the grains per gallon if soluble iron is present 

(1 ppm = 4 gpg). This screen will not display if “FILTER” mode is selected. 

  

STEP 3

 – 

DAYS BETWEEN REGENERATION (DAY OVERRIDE): 

Use the 

+

 or 

 buttons to adjust the day 

override. Adjustable from 1-28 days or OFF. The manufacturer has factory set OFF as the default for Twin 

units.
The Day Override value represents the maximum number of days between regenerations. If any number 

is set (1-28 days), a regeneration will be scheduled for that day if the gallon capacity has not been met.  If 

OFF is set, the unit will only initiate a regeneration once the gallon capacity has been met. 

STEP 4

 – 

IMMEDIATE REGENERATION:

 

The manufacturer has set the regeneration to occur when zero gallons 

remain. When this occurs, the standby tank will switch into service and provide treated water while the 

tank requiring regeneration will start this process. 

STEP 5

 – 

 SERVICE ALARM GALLONS:

 

Use the 

+

 or 

 buttons to schedule a service alarm by gallons. Adjustable 

in 100 gallon increments or OFF. The manufacturer has factory set OFF as the default. 

This feature is typically set by the installing dealer to warn the homeowner that service is required after 

a number of gallons have been consumed. If the feature is active, a specific gallon amount will appear. 

For more information regarding how to set service alarms, the installer should consult the master 

programming guide that corresponds to the unit being installed. 
Press the 

NEXT

 button three times to advance to the next screen. 

STEP 6

 – 

 SERVICE ALARM TIME:

 

Use the 

+

 or 

 buttons to schedule a service alarm in years. Adjustable in .25 

year increments or OFF. The manufacturer has factory set OFF as the default. 

This feature is typically set by the installing dealer to warn the homeowner that service is required after 

an amount of time has passed. If the feature is active, a specific number of days will appear. For more 

information regarding how to set service alarms, the installer should consult the master programming 

guide that corresponds to the unit being installed. 
Press the 

NEXT

 button three times to advance to the next screen.

2. Programming

Содержание CareSoft Elite RC Twin

Страница 1: ...For Models TC1 TW TC2 TW CSE TW CSP TW CSERC TW CSPRC TW TotalCare CareSoft Elite and CareSoft Pro Series Twin Water Softeners and Conditioners...

Страница 2: ...nd understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner contact your local dealer or the manuf...

Страница 3: ...time of day and gallons per minute Flow rate vacation mode capacity remaining and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance sect...

Страница 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...tall any water treatment unit with less than 10 feet of piping between its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer...

Страница 6: ...gap see drawing Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti siphon devices CAUTION Never insert a drain line into a dr...

Страница 7: ...7 This page intentionally left blank...

Страница 8: ...LTER mode is selected STEP 3 DAYS BETWEEN REGENERATION DAY OVERRIDE Use the or buttons to adjust the day override Adjustable from 1 28 days or OFF The manufacturer has factory set OFF as the default f...

Страница 9: ...ng the NEXT button proceeds to the Alarm Start Time screen This feature allows the installer to choose a time when the owner will be home or awake to hear the alarm BUZZER START TIME Press the or butt...

Страница 10: ...tarily press the button to advance the control to the BRINE position 4 With the bypass now in diagnostic mode Fig 3 on page 4 check to verify that water is being drawn from regenerant tank with no air...

Страница 11: ...ly the unit will trigger an immediate regeneration instead of a delayed regeneration For example if the unit s maximum Days Between Regeneration is reached while the unit is in Vacation Mode an immedi...

Страница 12: ...e brine tank as necessary making sure at least 1 3 of the brine tank is full at all times Without proper salt levels the water softener may not operate properly Because typical settings of this water...

Страница 13: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Страница 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body ty...

Страница 15: ...ton position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEX...

Страница 16: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Страница 17: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Страница 18: ...ews on each side that retain the transfer drive cap assemblies on both sides of the valve 8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor tran...

Страница 19: ...get under the drive cap while tightening as it will result in damaging the cable 17 Position the large white drive gear with the A pointing toward the one o clock position and then press it onto the...

Страница 20: ...1 2 CV3107 1 Motor 1 3 CV3002A Drive assembly Includes 5 and 6 4 CV4050WB PC board used on chlorine generator models 1 CV4062WX PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear co...

Страница 21: ...embly 1 3 CV3135 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 5 CV3174 Regenerant piston 1 6 CV3541 Drive backplate 1 REPLACEMENT PARTS IN OUT HEAD FOR TANK...

Страница 22: ...22 REPLACEMENT PARTS...

Страница 23: ...1 18 CV3264 WS2H bypass reduction gear axle 3 19 CV3110 WS1 drive reducing gear 12 x 36 3 20 CV3262 01 WS1 5 2 ALT 2BY reduction gear cover assembly 1 21 CV3592 Screw 8 1 PHPN T 25 SS 3 22 CV4049 T1 c...

Страница 24: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parkerfitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve the...

Страница 25: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Страница 26: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 27: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 41 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Страница 28: ...TANKS Item No Part No Description Qty CV4052 01 Interconnect kit for tanks 12 and larger 1 1 CV3151 Nut 1 QC 4 2 CV3150 Split ring 4 3 CV3105 O ring 215 4 4 CV3352 1 1 4 1 1 2 PVC solvent fitting 4 5...

Страница 29: ...Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628 Fitting 2...

Страница 30: ...30 This page intentionally left blank...

Страница 31: ...110 50 60 110 50 60 110 50 60 110 50 60 Pipe Size 1 1 1 1 1 1 Total Dimensions Media Tank and Valve 27 W x 52 H 29 W x 52 H 29 W x 62 H 31 W x 62 H 32 W x 74 H 34 W x 74 H Brine Tank 18 W x 33 H 18 W...

Страница 32: ...6 Service Flow Rate GPM P PSI 9 0 2 4 9 0 2 8 9 0 2 7 Water Pressure Range PSI 25 100 25 100 25 100 Water Temp F 33 100 33 100 33 100 Electrical Requirements volts hertz 110 50 60 110 50 60 110 50 60...

Страница 33: ...ponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manne...

Страница 34: ...TION BYPASS OPERATION ERROR 106 CALL FOR SERVICE QUICK REFERENCE GUIDE GENERAL OPERATION When the system is operating one of six displays will be shown 1 time of day gpm 2 flow rate 3 vacation mode 4...

Страница 35: ...llons ON with and buttons Default is OFF 9 Press NEXT 10 Turn service alarm by time ON with and buttons Default is OFF 11 Press NEXT three times 12 Turn alarm buzzer ON or OFF with and buttons 13 Pres...

Страница 36: ...2020 WaterCare All rights reserved MAN WC TWIN RevA0120 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406...

Отзывы: