page 24
PAUL
®
station
manual
PAUL Station Manual 2019-08-02
If you have mounted the
side outlet with hose
, see Figure 12, you can easily
hold the hose down so water can flow out.
6.2.2 Measurement of maximum filtration capacity
In order to do this, please follow the steps:
1. Assure that
PAUL
®
is filled up and enough water is in the RWT.
2. Assure that the effluent from
PAUL
®
is unobstructed. If a FWT is connected, the float
valve at the FWT inlet must be fully open.
3. Note all digits of the water meter, including the three red ones, see Figure 16, and the
exact date and time (seconds!)
Figure 16: meter reading
4. Let
PAUL
®
filter at least for 10 minutes, better 15 minutes, and then again note all dig-
its and the exact date and time
It is the easiest way to make a photo at start and end with a smartphone, as
then the exact date and time is included.
Please transfer this data (or, even
better, the photos) to us from time to time
.
A sample protocol is seen in Figure 17. Please download the template from