Installation Guide & Owner’s Manual – Under-the-Counter Reverse Osmosis Drinking Water System
Copyright © 2020 WaterAnywhere
All Rights Reserved.
Page 10
Notice:
Take extreme caution to not drill through to the other side of the drain pipe.
Install the Drain Clamp
Apply the foam gasket inside the front half of the drain saddle: Punch out the cut-out hole in the center of
the pad, remove the adhesive backing, and adhere to the inside of the drain saddle, ensuring the holes
are aligned.
Place one half of the plastic drain saddle assembly on each side of the drain pipe with the fitting, and
clamp loosely using the nuts and bolts included.
Align the hole drilled in the drain pipe with the hole in the drain saddle. A drill bit or other long narrow
object may be used to help align correctly.
Use Phillips screwdriver to tighten the clamp. Avoid over-tightening.
Connect Drain Line to RO System Reject Line
Insert tubing to the pipe stop in the quick connect fitting on the drain line and check the seal.
Connect the other end of the tubing to the flow restrictor outlet coming from the membrane brine port.
Step 4 – System Feed Line Installation
For this step you will need:
½”
and
7
/
16
” open-end wrenches (or two adjustable wrenches)
Teflon
Tape
Feed Adapter (in the size that matches your feed line) & Ball Valve Kit
Tubing
Locate and Turn Off the Cold Water Supply
Locate the valve in the cold water feed line you use for the supply.