           EE Man u al

Drawing No.

Order No.

Description

Quantity

1

V3175EE-01

WS1EE FRONT COVER ASSEMBLY

1

2

V3107-01

WS1 MOTOR

1

3

V3002-A

WS1 DRIVE BRACKET ASY

1

4

V3408EE-04BOARD

WS1THRU/2 EE PCB 5 DIGIT REPL

1

5

V3110

WS1 DRIVE GEAR 12X36

3

6

V3109

WS1 DRIVE GEAR COVER

1

7

V3106-01

WS1 DRIVE BRACKET & SPRING CLIP

1

Not Shown

V3186-05

WS1 POWER SUPPLY US 15VDC VI

1

V3186-01

WS1 POWER CORD ONLY

Not Shown

V3178

WS1 DRIVE BACK PLATE

1

EE Front Cover and Drive Assembly

4

AC Adapter

U.S.

International

Supply Voltage

120 V AC

230V AC

Supply Frequency

60 Hz

50 Hz

Output Voltage

15VDC

15VDC

Output Current

500 mA

500 mA

Refer to Control Valve Service Manual for other drawings and part numbers.

Relay Speci

fi

 cations: 12V DC Relay with a coil resistance 

not less than 80 ohms. If mounting relay under the cover 

check for proper mounting dimensions on the backplate.

Wiring for Correct On/Off Operation

PC Board Relay Terminal Block

Relay

RLY 1

Coil -

+ COM

Coil +

Battery replacement is 3 volt 

lithium coin cell type 2032.

Correct 

Battery 

Orientation

Battery Fully Seated

When replacing the battery, align 

positives and push down to fully seat.

PC Board Relay 

Terminal Block

1

2

5

6

7

3

Содержание EE

Страница 1: ...Water Specialist EE Control Valve Programming and Cover Drawing Manual...

Страница 2: ...Page 2 EE Manual...

Страница 3: ...rations and Functions 5 User Displays 6 Configuration Settings 7 OEM Softener System Setup 11 Setting Options Table 14 OEM Filter System Setup 15 Installer Display Settings Regeneration Type Auto 17 I...

Страница 4: ...nternational Supply Voltage 120 V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 15VDC 15VDC Output Current 500 mA 500 mA Refer to Control Valve Service Manual for other drawings and part numb...

Страница 5: ...e regeneration Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing in the program levels will go backwards...

Страница 6: ...f Day Push NEXT until time of day screen is displayed Press and hold until SET TIME is displayed and the hour flashes once Press or until the correct hour is displayed Then press NEXT The minutes will...

Страница 7: ...witch cannot be used for both controls on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system the MAV will transi...

Страница 8: ...ntrol operation For separate source operation the three wire communication cable is not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin conne...

Страница 9: ...ice Position MAV piston rod Extended WS1 WS1 25 and WS1 5 Valves For Clack Corporation alternator systems using WS1 WS1 25 and WS1 5 valves there will be an option to delay the last two cycles of rege...

Страница 10: ...to System Controller For communication between control valve and System Controller a three wire communication cable is required Selection requires that a connection to a Clack No Hard Water Bypass V30...

Страница 11: ...on time set This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 5S Press REGEN to return to previous step Step 4S Step 5S Select the time for the first cycle using or F...

Страница 12: ...not available on 0 is the default if Step 2CS is set to 1 0T and NORMAL on 0 is not available See Setting Options Table for more detail Press NEXT to go to Step 14S Press REGEN to return to previous...

Страница 13: ...e meter Ranges from 1 to 200 gallons Press NEXT to go to Step 16S Press REGEN to return to previous step Step 16S Set Relay Deactivate Time using or If Set Time on is selected in Step 14S the relay wi...

Страница 14: ...e capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 Any number On 0 oFF Reserve capacity NOT automatically est...

Страница 15: ...the first cycle using or Press NEXT to go to Step 4F Press REGEN to return to previous step Step 3F Step 4F Select the time for the second cycle using or If Step 2F is set to FILTERING REGEN press NE...

Страница 16: ...ng on Relay activates after a set number of gallons have been used while in service and then deactivates after the meter stops registering flow and the set time period has expired Gallons Filtering Re...

Страница 17: ...e from 1 to 28 regeneration initiation will be called for on that day regardless of actual water usage Set Day Override using or number of days between regeneration 1 to 28 or oFF See Setting Options...

Страница 18: ...tween regeneration 1 to 28 See Setting Options Table for more detail on setup Press NEXT to go to step 3I Press REGEN to return to previous step Step 2I Step 3I Next Regeneration Time hour Set the hou...

Страница 19: ...Step 2I Step 3I Scroll through days 1 to 7 using NEXT Use or to turn regen ON or OFF for each individual day After completing the 7th day press NEXT to go to Step 4I Press REGEN to go to previous dis...

Страница 20: ...ows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 6D Press REGEN to return to previous step Step 5D Step 6D Error Log This display shows a hist...

Страница 21: ...f A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits represent the number of hours ago that the transfer occurred The dis...

Страница 22: ...Page 22 EE Manual...

Страница 23: ...EE Manual Page 23...

Страница 24: ...MAL not adjustable Any number Reserve capacity not automatically estimated 28 day Regeneration occurs at the next Regen Set Time when the specified number of days between regenerations is reached 7 da...

Отзывы: