Page 16

 

 

           EE Man u al

Step 9F –

 Set Relay Actuation Time or Gallons using 

 or 

. The choices are:

• Relay Actuation Time: After the start of a regeneration the amount of time that should pass prior 
to activating the relay. The start of regeneration is de

fi

 ned as the 

fi

 rst backwash cycle or brine cycle, 

whichever comes 

fi

 rst. Ranges from 1 second to 200 minutes.

• Relay Actuation Gallons: Relay activates after a set number of gallons has passed through the meter. 
Ranges from 1 to 200 gallons.
Press NEXT to go to Step 10F. Press REGEN to return to previous step.

Step 9F

Step 10F –

 Set Relay Deactivate Time using 

 or 

.

• If Set Time on is selected in Step 8F the relay will deactivate after the time set has expired. Ranges from 1 
second to 200 minutes.
• If Set Gallons Filtering on or Set Gallons Filtering Regen on is selected in Step 8F the relay will 
deactivate after the time set has expired or after the meter stops registering 

fl

 ow, whichever comes 

fi

 rst. 

Ranges from 1 second to 20 minutes.
Press NEXT to exit OEM Filter System Setup. Press REGEN to return to previous step.

Step 10F

EXIT OEM FILTER SYSTEM SETUP           

Step 8F –

 Set Relay Operation using 

 or 

. The choices are:

• Time on: Relay activates after a set time at the beginning of a 
regeneration and then deactivates after a set period of time. The start of 
regeneration is de

fi

 ned as the 

fi

 rst backwash cycle or Dn brine cycle, 

whichever comes 

fi

 rst.

• Gallons Filtering on: Relay activates after a set number of gallons 

have been used while in service and then deactivates after the meter stops registering 

fl

 ow and the set time 

period has expired.
• Gallons Filtering Regen on: Relay activates after a set number of gallons have been used while in service, 
or during regeneration, and then deactivates after the meter stops registering 

fl

 ow and the set time period 

has expired.
•ERROR: Relay closes whenever the valve enters error mode, and immediately deactivates when error 
mode is exited. If set to ERROR, Steps 9F and 10F will not be shown.
• Off: If set to Off, Steps 9F and 10F will not be shown.
Press NEXT to go to Step 9F. Press REGEN to return to previous step.

Step 8F

Step 7F –

 Set Regeneration Time Options using 

 or 

. NOTE: This step will not appear if Step 5F is set 

to oFF or Step 5CS is set to “SYS”.
If value is set to:
• “NORMAL” means regeneration will occur at the preset time;
• “on 0” means regeneration will occur immediately when the volume capacity reaches 0 (zero); or
• “ on 0” means regeneration will occur at one of the following:
— the preset time when the volume capacity falls below the reserve or the speci

fi

 ed number of days 

between regenerations is reached whichever comes 

fi

 rst; or

— immediately after 10 minutes of no water usage when the volume capacity reaches 0 (zero).
“NORMAL” is the default if Step 5CS is set to ALT A or ALT B, and “ on 0” is not available.
“on 0” is the default if Step 2CS is set to 1.0T , and “ on 0” is not available.
See Setting Options Table for more detail. Press NEXT to go to Step 8F. Press REGEN to return to previous 
step.

Step 7F

Содержание EE

Страница 1: ...Water Specialist EE Control Valve Programming and Cover Drawing Manual...

Страница 2: ...Page 2 EE Manual...

Страница 3: ...rations and Functions 5 User Displays 6 Configuration Settings 7 OEM Softener System Setup 11 Setting Options Table 14 OEM Filter System Setup 15 Installer Display Settings Regeneration Type Auto 17 I...

Страница 4: ...nternational Supply Voltage 120 V AC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 15VDC 15VDC Output Current 500 mA 500 mA Refer to Control Valve Service Manual for other drawings and part numb...

Страница 5: ...e regeneration Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing in the program levels will go backwards...

Страница 6: ...f Day Push NEXT until time of day screen is displayed Press and hold until SET TIME is displayed and the hour flashes once Press or until the correct hour is displayed Then press NEXT The minutes will...

Страница 7: ...witch cannot be used for both controls on0 If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system the MAV will transi...

Страница 8: ...ntrol operation For separate source operation the three wire communication cable is not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin conne...

Страница 9: ...ice Position MAV piston rod Extended WS1 WS1 25 and WS1 5 Valves For Clack Corporation alternator systems using WS1 WS1 25 and WS1 5 valves there will be an option to delay the last two cycles of rege...

Страница 10: ...to System Controller For communication between control valve and System Controller a three wire communication cable is required Selection requires that a connection to a Clack No Hard Water Bypass V30...

Страница 11: ...on time set This screen is not viewed when Step 2S is set to Filtering Press NEXT to go to Step 5S Press REGEN to return to previous step Step 4S Step 5S Select the time for the first cycle using or F...

Страница 12: ...not available on 0 is the default if Step 2CS is set to 1 0T and NORMAL on 0 is not available See Setting Options Table for more detail Press NEXT to go to Step 14S Press REGEN to return to previous...

Страница 13: ...e meter Ranges from 1 to 200 gallons Press NEXT to go to Step 16S Press REGEN to return to previous step Step 16S Set Relay Deactivate Time using or If Set Time on is selected in Step 14S the relay wi...

Страница 14: ...e capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 Any number On 0 oFF Reserve capacity NOT automatically est...

Страница 15: ...the first cycle using or Press NEXT to go to Step 4F Press REGEN to return to previous step Step 3F Step 4F Select the time for the second cycle using or If Step 2F is set to FILTERING REGEN press NE...

Страница 16: ...ng on Relay activates after a set number of gallons have been used while in service and then deactivates after the meter stops registering flow and the set time period has expired Gallons Filtering Re...

Страница 17: ...e from 1 to 28 regeneration initiation will be called for on that day regardless of actual water usage Set Day Override using or number of days between regeneration 1 to 28 or oFF See Setting Options...

Страница 18: ...tween regeneration 1 to 28 See Setting Options Table for more detail on setup Press NEXT to go to step 3I Press REGEN to return to previous step Step 2I Step 3I Next Regeneration Time hour Set the hou...

Страница 19: ...Step 2I Step 3I Scroll through days 1 to 7 using NEXT Use or to turn regen ON or OFF for each individual day After completing the 7th day press NEXT to go to Step 4I Press REGEN to go to previous dis...

Страница 20: ...ows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 6D Press REGEN to return to previous step Step 5D Step 6D Error Log This display shows a hist...

Страница 21: ...f A then the tank with the valve on it was in service if b the tank with the in out head on it was in service The next three digits represent the number of hours ago that the transfer occurred The dis...

Страница 22: ...Page 22 EE Manual...

Страница 23: ...EE Manual Page 23...

Страница 24: ...MAL not adjustable Any number Reserve capacity not automatically estimated 28 day Regeneration occurs at the next Regen Set Time when the specified number of days between regenerations is reached 7 da...

Отзывы: