background image

34

Water Softener Limited Warranty

Congratulations. You have purchased one of the fi nest water treatment systems available. In the unlikely 
event of a problem due to defects in material and workmanship, we proudly warrant our water softeners to 
the original owner, when installed in accordance with Water-Right

®

 specifi cations. This warranty is effective 

from the date of original installation for:

A period of TEN YEARS: 

 

 Fiberglass mineral tanks 13” and smaller; except for damages 
due to freezing, high pressure (120 PSI and above), extreme 
temperature (100°F and above) or a vacuum on the system. 

A period of FIVE YEARS: 

 

The control valve and all internal components.

 

 

 

 

 

Fiberglass mineral tanks 14” and larger.

     The 

salt 

storage 

container.

A period of ONE YEAR: 

 

All other softener components.

Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay 
only freight from our factory and local dealer charges. To obtain local warranty service, contact original dealer 
or an authorized service dealer. If no authorized dealer is located in your area, please ship defective part or 
component freight prepaid to Water-Right, Inc., 1900 Prospect Ct., Appleton, Wisconsin 54914. Water-Right,  
at its discretion, will repair or replace the part or component at its expense and return part freight collect.

The above provisions of the warranty are valid as long as the unit is connected in compliance with local 
plumbing codes and in an equivalent manner and condition of the original installation and is owned by the 
original owner.
 
This warranty does not cover damages due to accident, fi re, fl ood, freezing, or any other Act of God.  
We are not responsible for damages due to change in water conditions, misapplication, misuse, neglect, 
vacuum, oxidizing agents, alteration, or lack of maintenance. No responsibility is assumed for loss of use 
of the unit, inconvenience, loss or damage to real or personal property or any incidental or consequential 
damages. Furthermore, we assume no liability and extend no warranties, express or implied, for the use 
of this product with a non-potable water source. 

To the extent permitted by law, Water-Right disclaims 

all implied warranties, including without limitation warranties of merchantability and fi tness for 
particular purpose; to the extent required by law, any such implied warranties are limited in duration 
to the aforementioned period specifi ed above.

Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty 
lasts. Consequently, the above limitation may not apply to you.

This warranty gives you specifi c legal rights, and you may also have other rights which vary from state    
to state.

Содержание Impression Plus Series

Страница 1: ...Twin Water Softeners For Models IMP 844TW ASP1 1044TW IMP 1044TW ASP1 1054TW IMP 1054TW ASP1 1354TW IMP 1354TW ASP1 1465TW IMP 1465TW ASP1 1665TW IMP 1665TW IMPRC 1054TW ASP2 1044TW IMPRC 1354TW ASP2...

Страница 2: ...rated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water...

Страница 3: ...dels Read Normal Operating Displays Set Time of Day Read Power Loss Error Display Be sure system and installation are in compliance with all state and local laws and regulations For the homeowner plea...

Страница 4: ...r flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Страница 5: ...a firm level surface 1 The distance between the drain and the water conditioner should be as short as possible see step 8 2 Since salt must be periodically added to the brine tank it should be locate...

Страница 6: ...s could cause interior damage to the flow control Install a 1 2 I D flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3 4 NPT fitting for rigid pipe recommended If...

Страница 7: ...tion however an overflow line connection will direct the overflow to the drain instead of spilling on the floor where it could cause considerable damage This fitting is an elbow on the side of the bri...

Страница 8: ...ation initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration By default this regeneration will occur at 2 00 a m Set Day Override usi...

Страница 9: ...ed time after a regeneration if there is no salt or if another error has occurred Turn the alarm OFF or ON using the or buttons Press NEXT NOTE This feature allows you to program the time in which the...

Страница 10: ...ess the REGEN button to advance the control to the BRINE position 4 With the bypass now in diagnostic mode Fig 3 on page 4 check to verify that water is being drawn from regenerant tank with no air le...

Страница 11: ...dby tank online so there is no disruption of treated water Once this transfer is complete the depleted tank will regenerate and return to standby mode ready to enter service upon depletion of capacity...

Страница 12: ...ally indicates that the salt level in the brine tank is too low to operate properly If CHECK SALT appears there will usually be an audible alarm that sounds also if turned on alerting you to these con...

Страница 13: ...Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed secure...

Страница 14: ...G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type a...

Страница 15: ...ston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NE...

Страница 16: ...seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not conne...

Страница 17: ...uzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply...

Страница 18: ...ews on each side that retain the transfer drive cap assemblies on both sides of the valve 8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor tran...

Страница 19: ...re to be certain the meter cable doesn t get under the drive cap while tightening as it will result in damaging the cable 17 Position the large white drive gear with the A pointing toward the one o cl...

Страница 20: ...cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV3554WS PC board for Sanitizer Plus 1 CV3813WP PC board for Impression Plus 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Dr...

Страница 21: ...embly 1 3 CV3135 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 5 CV3174 Regenerant piston 1 6 CV3541 Drive backplate 1 REPLACEMENT PARTS IN OUT HEAD FOR TANK...

Страница 22: ...22 REPLACEMENT PARTS...

Страница 23: ...1 18 CV3264 WS2H bypass reduction gear axle 3 19 CV3110 WS1 drive reducing gear 12 x 36 3 20 CV3262 01 WS1 5 2 ALT 2BY reduction gear cover assembly 1 21 CV3592 Screw 8 1 PHPN T 25 SS 3 22 CV4049 T1 c...

Страница 24: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parker fitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve th...

Страница 25: ...embly BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GR...

Страница 26: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 27: ...1030 36S 4 x 36 slotted brine well 18 x 40 24 x 41 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620 474 float assembly 7 1 8 CH4600 50 474 safety brine val...

Страница 28: ...TANKS Item No Part No Description Qty CV4052 01 Interconnect kit for tanks 12 and larger 1 1 CV3151 Nut 1 QC 4 2 CV3150 Split ring 4 3 CV3105 O ring 215 4 4 CV3352 1 1 4 1 1 2 PVC solvent fitting 4 5...

Страница 29: ...CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2...

Страница 30: ...2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105...

Страница 31: ...31 This page left intentionally blank...

Страница 32: ...26 0 25 0 26 0 25 0 Continuous Flow Rate GPM P PSI 9 0 2 4 9 0 2 8 9 0 2 7 19 0 15 0 19 0 15 0 Water Pressure Range PSI 25 100 25 100 25 100 25 100 25 100 Water Temp F 33 100 33 100 33 100 33 100 33...

Страница 33: ...100 30 100 30 100 30 100 30 100 30 100 Water Temperature F 33 100 33 100 33 100 33 100 33 100 33 100 Electrical Requirements volts hertz 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 110 50 60 Pi...

Страница 34: ...r replace the part or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes a...

Страница 35: ...ess NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6 Adjust current day with and buttons 7 Press NEXT to complete and return to normal operation DAYS TO A REGEN GPM 3 A FLOW RATE GPM 8 0 TIME OF...

Страница 36: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2018 Water Right All rights reserved MAN WR TWIN RevA0818...

Отзывы: