background image

11

5.

ERROR MESSAGE:

If the word “ERROR” and a number are

alternately flashing on the display record the number and contact
the dealer for help. This indicates that the control valve was not
able to function properly.

6.  

BRINE TANK MAINTENANCE AND SALT:

Refill the brine tank as necessary, making sure at

least 1/3 of the brine tank is full at all times. Without proper salt levels, the water softener may
not operate properly.

Because “typical” settings of this water softener include a dry salt storage feature (no water in
brine tank between regeneration), the manufacturer recommends the use of solar salt for best
results. The brine tank is manufactured for the use of solar, pellets or rock salt. If pellet or rock
salt is used, a cleaning of the brine tank every six months is recommended. If the dry salt
storage feature is not being utilized, block salt may be used.

CAUTION:

The manufacturer does not recommend the use of any
resin cleaners, nor placement of any resin cleaners into
the brine tank. This may be harmful to the water
softener and for human consumption. Consult dealer
for proper cleaning instructions.

ERROR

Содержание IMP-844

Страница 1: ...Impression Plus Series Metered Water Softeners For Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 For Cabinet Models IMPC 835 IMPC 935 IMPC 1035...

Страница 2: ...ome when installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any ques...

Страница 3: ...kly exit any Programming Installer Settings etc press SET CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the prese...

Страница 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Страница 5: ...liers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 30 100...

Страница 6: ...lamp or jumper wiring NOTE If replacing an existing softener also replace the ground clamps wire If removing a softener replace the piping with the same type of piping as the original to assure plumbi...

Страница 7: ...ilding structure Your softener is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow In the event of a malfunction however an overflow line connec...

Страница 8: ...DNESS Set the amount of hardness in grains per gallon default 20 using the or buttons The allowable range is from 1 to 150 in 1 grain increments Note Increase the grains per gallon if soluble iron is...

Страница 9: ...nd display shows the current treated water flow rate through the system in Gallons Per Minute The third display is one of the following days remaining or volume remaining Days remaining is the number...

Страница 10: ...thereafter see Start Up Instructions for regeneration sequence the water softener will deliver water but it will be untreated IMPORTANT With the Dry Salt Storage Feature the brine tank will refill 4 h...

Страница 11: ...er softener include a dry salt storage feature no water in brine tank between regeneration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use...

Страница 12: ...up it could result in a salty water complaint after the first regeneration During the first regeneration the unit will draw out the initial volume of brine regenerant and refill it with the correct pr...

Страница 13: ...any remaining debris and air from the system again 1 Full open a cold water faucet preferably at a laundry sink or bathtub without an aerator 2 Wait two to three minutes or until water runs clear then...

Страница 14: ...ed stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into t...

Страница 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...

Страница 16: ...t power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGEN buttons for 3...

Страница 17: ...ttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wir...

Страница 18: ...pression cover 1 CV3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3579WI PC board CC 1 5 CV3110 Drive gear...

Страница 19: ...11 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4...

Страница 20: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...

Страница 21: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...

Страница 22: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Страница 23: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve...

Страница 24: ...24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4640 32 474 float assembly 32 w 2 grommets 1 8 CH4600 50 474 safety brine valve w 5 gpm glow control 1...

Страница 25: ...ion Qty 1 CG2197 01 Salt and tank cover must be ordered together 1 2 CG2724HP 01 Windsor cabinet white with black lids 1 3 CH1090 01 Optional salt grid for 8 diameter tank and 4 brine well 1 CH1090 02...

Страница 26: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Страница 27: ...3375 Fitting 2 1 BRASS SHARK BITE Item No Part No Description Qty CV3007 13 1 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2...

Страница 28: ...ssure Loss at Max Service PSI 8 6 14 1 15 0 Min to Max Working Pressure PSI 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1...

Страница 29: ...mponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent mann...

Страница 30: ...30 NOTES...

Страница 31: ...31...

Страница 32: ...s as shown to the right Access this mode by pressing NEXT and button simultaneously NOTE Hardness display shows nA if used as a filter If other displays do not appear refer to manual QUICK REFERENCE G...

Отзывы: