8. 

 INSTALLING  GROUND:

 To maintain an electrical ground in metal plumbing of a home’s cold water piping 

(such as a copper plumbing system), install a ground clamp or jumper wiring. 

NOTE: If replacing an existing unit, also replace the ground clamps/wire. If removing a unit, replace 

the piping with the same type of piping as the original to assure plumbing integrity and grounding. 

9.

  

DRAIN LINE:

 First, be sure that the drain can handle the backwash rate of the system. Solder joints near 

the drain must be done prior to connecting the drain line flow control fitting. Leave at least 6” between 

the drain line flow control fitting and solder joints. Failure to do this could cause interior damage to the 

flow control. Install a 1/2” I.D. tube to the Drain Line Assembly in accordance with plumbing regulations or 

discard the tubing nut and use the 3/4” NPT fitting for rigid pipe (recommended). If the backwash rate is 

greater than 7 gpm, use a 3/4” drain line. Where the drain line is elevated but empties into a drain below the 

level of the control valve, form a 7” loop at the discharge end of the line so that the bottom of the loop is level with the drain connection on the 

control valve. This will provide an adequate anti-siphon trap. Piping the drain line overhead <10 ft is normally not a problem. Be sure adequate 

pressure is available (40-60 psi is recommended). Where the drain empties into an overhead sewer line, a sink-type trap must be used with 

appropriate air gap (see drawing). Run drain tube to its discharge point in accordance with plumbing codes. Pay special attention to codes for 

air gaps and anti-siphon devices.

CAUTION:  Never insert a drain line into a drain, sewer line, or trap. Always allow an air gap of 1-1/2” or twice the pipe 

diameter, whichever is greater, between the drain line and the wastewater to prevent the possibility of sewage 

being back-siphoned into the softener.

SHUTOFF

VALVE

GROUND

STRAP

TYPICAL DRAIN LINE INSTALLATIONS

GROUND STRAP

INSTALLATION

1. Floor Drain

2. Standpipe

3. Laundry Tub

10.   

SAFETY BRINE TANK CONNECTION:

 Install the 3/8” O.D. polyethylene tube from the Refill Elbow to the Brine Safety Float valve in the 

brine tank.

11.  

OVERFLOW LINE CONNECTION:

 An overflow drain line is recommended where a brine overflow could damage furnishings or the building 

structure. Your unit is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow. In the event of 

a malfunction, however, an overflow line connection will direct the “overflow” to the drain instead of spilling on the floor where it could cause 

considerable damage. This fitting is an elbow on the side of the brine tank. Attach a length of 1/2” I.D. tubing to fitting and run to drain. Do not 

elevate overflow line higher than 3” below bottom of overflow fitting. Do not connect this tube into the drain line of the control valve. Overflow 

line must be a direct, separate line from overflow fitting to drain, sewer, or tub. Allow an air gap as per the drain line instructions.

Connection at Refill Elbow on the control valve

Connection at Brine Safety Float in brine tank

Содержание IMP-1044

Страница 1: ...stallation Instructions Owner s Manual Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 10...

Страница 2: ...ully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer YOUR WATE...

Страница 3: ...Flow rate capacity remaining and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operatin...

Страница 4: ...es point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve for normal operation of a water softener or filter During the regeneration...

Страница 5: ...nds the use of an expansion tank on the outlet side of the unit see diagram 5 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to temperatur...

Страница 6: ...th appropriate air gap see drawing Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti siphon devices CAUTION Never insert a dr...

Страница 7: ...7 This page intentionally left blank...

Страница 8: ...gallons Adjustable from 1 to 150 gpg in 1 grain increments default setting is 20 The hardness value is based on the actual compensated hardness of the water and must be set by an authorized dealer fo...

Страница 9: ...let handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media to the drain 3 When the water...

Страница 10: ...ater use is anticipated or when the system has been operating without salt To initiate a manual regeneration at the next preset regeneration time press and release the REGEN button The words REGEN TOD...

Страница 11: ...cedures and initiate regeneration see operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERRO...

Страница 12: ...B Connect meter to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into...

Страница 13: ...mming Check refill flow control for restrictions or debris and if necessary replace H Damaged seal stack assembly piston H Replace seal stack assembly and or piston I Control valve body type and pisto...

Страница 14: ...n the PC board labeled MOTOR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC bo...

Страница 15: ...V NHBP motor to PC board two pin connection labeled DRIVE Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 secon...

Страница 16: ...ory screens These do not flash when error occurs A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error A Check for low...

Страница 17: ...V3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor Assembly 1 3 CV3002 A Drive assembly includes 5 and 6 1 4 CV3579WI 03 PC board Impression 1 CV4229XP 03...

Страница 18: ...CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 12 CV3015A WS1 QC2 Tank adapter assembly includes O rings 1 13 CV3001 04 1 body assembly dow...

Страница 19: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parkerfitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve the...

Страница 20: ...assembly CV3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown C...

Страница 21: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 22: ...4 CH1030 29S 4 x 29 slotted brine well 18 x 33 BT 1 CH1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620...

Страница 23: ...y with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with Brine Well 474 Assembly 34 5 8 1 LOW PROFILE CABINET AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWSLP C Top Assembly Black...

Страница 24: ...t No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628 Fitting 2 1 PL...

Страница 25: ...ins Lbs Salt N A 4 040 1 Max Service Flow Rate GPM 9 6 16 0 Max Pressure Loss at Max Service PSI 9 0 15 0 Min to Max Working Pressure PSI 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100...

Страница 26: ...art or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equiva...

Страница 27: ...power outage 1 Accessed by pressing 2 Adjust hours with or buttons AM PM toggles at 12 3 Press 4 Adjust minutes with or buttons 5 Press 6 Adjust current day with or buttons 7 Press to complete and ret...

Страница 28: ...2021 Water Right Inc All rights reserved MAN IMP CERT RevA0821 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406...

Отзывы: