Water Right IMP-1044 Скачать руководство пользователя страница 25

24

25

SPECIFICATIONS

Manufactured by Water-Right, Inc.  •  1900 Prospect Court  •  Appleton, WI 54914  •  800-777-1426  •  water-right.com                   

  

 

             SPE-IMP CERT RevA0720

* All Impression Plus water softeners are set at “minimum salting” from the factory.

Cabinet dimensions represent the High-Profile cabinet option. Low-Profile cabinets    

    

 are about one inch shorter in height than the High-Profile cabinet lid. 

Impression Plus Series

®

Specifications

CABINET MODEL (IMPC) SPECIFICATIONS

MODEL

IMP-844

IMP-948

IMP-1044

IMP-1054

IMP-1248

IMP-1354

Rated Softener 

Capacity:*

(Grains/Lbs. Salt)

Minimum

13,700 @ 3.4

18,200 @ 4.5

18,200 @ 4.5

27,600 @ 7.0

36,400 @ 9.0

45,800 @ 11.5

Medium

16,800 @ 6.0

23,500 @ 9.0

23,500 @ 9.0

36,700 @ 15.0

47,000 @ 18.0

53,900 @ 18.0

Maximum

18,800 @ 8.0

28,000 @ 15.0

28,000 @ 15.0

42,000 @ 22.5

56,100 @ 30.0

69,800 @ 37.0

Amount of  High Capacity Cat-ion Resin Media (Cu. Ft.)

.75

1.0

1.0

1.5

2.0

2.5

Efficiency at 1 lb Salt Setting (Grains/Lbs Salt)

4,040/1

4,040/1

4,040/1

4,040/1

4,040/1

4,040/1

Max. Service Flow Rate (GPM)

11.7

13.1

16.0

13.3

16.4

17.1

Max. Pressure Loss at Max. Service (PSI)

15

15

15

15

15

15

Min. to Max. Working Pressure (PSI)

30-100

30-100

30-100

30-100

30-100

30-100

Min. to Max. Operating Temperature (ºF)  

33-100

33-100

33-100

33-100

33-100

33-100

Max. Flow to Drain During Regeneration (GPM)

1.3

1.7

2.2

2.2

3.2

3.2

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

110-50/60

Pipe Size

1”

1”

1”

1”

1”

1”

Total Dimensions:

Media Tank and Valve

8”W x 52”H

9”W x 56”H

10”W x 52”H

10”W x 62”H

12”W x 56”H

13”W x 62”H

Brine Tank

18”W x 33”H

18”W x 33”H

18”W x 33”H

18”W x 33”H

18”W x 40”H

18”W x 40”H

MODEL

IMPC-835

IMPC-1035

Rated Softener 

Capacity:*

(Grains/Lbs. Salt)

Minimum

5,100 @ 2.3

18,200 @ 4.5

Medium

7.300 @ 6.0

23,500 @ 9.0

Maximum

7,800 @ 7.5

28,000 @ 15.0

Amount of High Capacity Cat-ion Resin Media (Cu. Ft.)

.50

1.0

Efficiency at 1 lb Salt Setting (Grains/Lbs Salt)

N/A

4,040/1

Max. Service Flow Rate (GPM)

9.6

16.0

Max. Pressure Loss at Max. Service (PSI)

9.0

15.0

Min. to Max. Working Pressure (PSI)

30-100

30-100

Min. to Max. Operating Temperature (ºF)  

33-100

33-100

Max. Flow to Drain During Regeneration (GPM)

1.3

2.2

Electrical Requirements (volts-hertz)

110-50/60

110-50/60

Pipe Size

1”

1”

Total Dimensions:

Cabinet

14” x 44.5”H x 

20.5”D

14” x 44.5”H x 

20.5”D

IMP SPECIFICATIONS

Width

Width

Height

Height

Depth

Low Profi le Cabinet

High Profi le Cabinet

CYCLE TIMES (in minutes)

MODEL

IMP-835

IMP-948

IMP-1044

IMP-1054

IMP-1248

IMP-1354

IMPC-835

IMPC-1035

Brine Refill

2

3

3

4.5

6

7.5

1.5

3

Regenerant (lbs)

3.4

4.5

4.5

7.0

9.0

11.5

2.3

4.5

Service

240

240

240

240

240

240

240

240

The above sequence takes place prior to regeneration; therefore, minutes are not included in totals.

Backwash

6

8

8

8

10

10

6

8

Brine and Rinse

40

60

60

90

90

90

40

60

Rinse

4

4

4

4

4

4

4

4

Total

50

72

72

102

104

104

50

72

Manufacturer recommends the use of coarse solar salt in these water softeners.
IMP -844, -948, -1044, -1054, -1248, -1354 and IMPC -835 -1035 softeners are certified by WQA against NSF/ANSI Standard 44 for the reduction of hardness as verified 

and substantiated by test data.
Only the efficiency-rated water softener models have a rated capacity of not less than 3,350 grains of total hardness exchange per pound of salt (based on NaCl) and 

shall not deliver more salt or be operated at a sustained maximum service flow rate greater than its listed rating. Efficiency is measured by a laboratory test described 

in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve after the system has been installed. The operational efficiency is typically 

less than the efficiency due to individual application factors including water hardness, water usage, and other contaminants that reduce the softener’s capacity.
These water softeners are not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or 

after the system.

Содержание IMP-1044

Страница 1: ...stallation Instructions Owner s Manual Impression Plus Series Metered Water Softeners For Certified Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 Certified Cabinet Models IMPC 835 IMPC 10...

Страница 2: ...ully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water softener contact your local dealer YOUR WATE...

Страница 3: ...Flow rate capacity remaining and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operatin...

Страница 4: ...es point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve for normal operation of a water softener or filter During the regeneration...

Страница 5: ...nds the use of an expansion tank on the outlet side of the unit see diagram 5 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to temperatur...

Страница 6: ...th appropriate air gap see drawing Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti siphon devices CAUTION Never insert a dr...

Страница 7: ...7 This page intentionally left blank...

Страница 8: ...gallons Adjustable from 1 to 150 gpg in 1 grain increments default setting is 20 The hardness value is based on the actual compensated hardness of the water and must be set by an authorized dealer fo...

Страница 9: ...let handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air CAUTION If water flows too rapidly there will be a loss of media to the drain 3 When the water...

Страница 10: ...ater use is anticipated or when the system has been operating without salt To initiate a manual regeneration at the next preset regeneration time press and release the REGEN button The words REGEN TOD...

Страница 11: ...cedures and initiate regeneration see operating displays and maintenance If these procedures do not remedy the problem please consult the installing dealer for service 5 ERROR MESSAGE If the word ERRO...

Страница 12: ...B Connect meter to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into...

Страница 13: ...mming Check refill flow control for restrictions or debris and if necessary replace H Damaged seal stack assembly piston H Replace seal stack assembly and or piston I Control valve body type and pisto...

Страница 14: ...n the PC board labeled MOTOR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC bo...

Страница 15: ...V NHBP motor to PC board two pin connection labeled DRIVE Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 secon...

Страница 16: ...ory screens These do not flash when error occurs A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error A Check for low...

Страница 17: ...V3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor Assembly 1 3 CV3002 A Drive assembly includes 5 and 6 1 4 CV3579WI 03 PC board Impression 1 CV4229XP 03...

Страница 18: ...CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 12 CV3015A WS1 QC2 Tank adapter assembly includes O rings 1 13 CV3001 04 1 body assembly dow...

Страница 19: ...1 CV3195 01 Refill port plug assembly 1 2 CH4615 Elbow locking clip 1 3 CV4144 3 8 Elbow Parkerfitting 1 4 CV3163 O ring 019 1 Although no tools are necessary to assemble or disassemble the valve the...

Страница 20: ...assembly CV3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown C...

Страница 21: ...n 1 Strt No Sil 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elb...

Страница 22: ...4 CH1030 29S 4 x 29 slotted brine well 18 x 33 BT 1 CH1030 36S 4 x 36 slotted brine well 18 x 40 24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4620...

Страница 23: ...y with 474 Brine Assembly 1 Not shown CH4850 34 625 Brine Well with Brine Well 474 Assembly 34 5 8 1 LOW PROFILE CABINET AND BRINE TANK Item No Part No Description Qty 1 CJ2TCWSLP C Top Assembly Black...

Страница 24: ...t No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628 Fitting 2 1 PL...

Страница 25: ...ins Lbs Salt N A 4 040 1 Max Service Flow Rate GPM 9 6 16 0 Max Pressure Loss at Max Service PSI 9 0 15 0 Min to Max Working Pressure PSI 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100...

Страница 26: ...art or component at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equiva...

Страница 27: ...power outage 1 Accessed by pressing 2 Adjust hours with or buttons AM PM toggles at 12 3 Press 4 Adjust minutes with or buttons 5 Press 6 Adjust current day with or buttons 7 Press to complete and ret...

Страница 28: ...2021 Water Right Inc All rights reserved MAN IMP CERT RevA0821 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406...

Отзывы: