Installation
8
preferred method. When selecting a mounting location, leave enough space to allow the removal of the UV lamp and/or
quartz sleeve (typically leave a space equal to the size of the chamber itself).
3.
Mount the system to the wall using the supplied clamps. Various connection methods can be used to connect the water
source to the system, however union type connectors are recommended. The use of a flow restrictor device will help to
maintain the manufacturers rated flow. The flow restrictor should be installed on the outlet port and is designed to be
installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated on the flow
restrictor. Refer to
Figure 5
.
Note:
DO NOT solder connections while attached to the system as this could damage the O-ring seals.
4.
Mount the VIQUA ICE controller horizontally to the wall, near the chamber. Ideally place the controller above the
chamber and away from any water connection point, to prevent any water from potentially leaking onto the controller by
means of a leak at a connection point or a “sweating” system. Make sure you allow for a “drip-loop” as shown in
Figure 6
on the lamp, sensor, and power cord, again, to prevent any water from potentially entering the controller.
Figure 4 Installation - Vertical and Horizontal
Figure 5 Flow Restrictor
A
B
Unit overall length
Min. clearance equal
to unit overall length
Unit overall length
Min. clearance equal
to unit overall length
Flow
restrictor
Optional temparature
management valve
Flow