![Water Protec LED 13 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/water-protec/led-13/led-13_owners-manual_3563995010.webp)
User guide
886E - WIFI Version
8
Additional information
Replacing the remote control
In the case of loss or failure, to replace a remote control that has already been synchronized with a control panel,take the following
steps: First, push the
Program
button on the control panel to activate Program mode. The control panel is in Program Mode when
the first LED is flashing. When the first led flashes, After push the
Reset
button on the control panel three times. The first three LEDs
should start to flash. Unit is ready to receive a syncronization signal from a remote control.
Replacing or adding a water sensor
Set the Main Control to Program Mode by pressing the
Program
button. The first LED will flash. Push the
Open
button on the
remote control – each push will move the flashing LED to the next position. When the desired position is reached, synchronize the new
sensor by shorting the electrodes as described previously. The selected LED should now be continuously lit, and the next one, flashing.
Battery replacement
Sensors
The water sensors are equipped with two 3V/20mm lithiumcoin cells (ex.: Panasonic CR2032).
To replace, open the sensor case by removing one fixing screw, remove old batteries and replace
with new – carefully observing marked polarity (Positive upward). Replace the cover and
return to service. (Note: the sensor will function with only one battery in place, with reduced
lifetime.)
Remote control
The Remote Control is equipped with one 3V / 16mm lithium coin cell
(ex.: Panasonic CR-1632). The case snaps open with a fingernail.
Control Panel
The control panel is equipped with one 9V Battery (ex.: Energizer EN22). To replace, slide out the access hatch from control panel,
remove the old battery and insert the new, then replace the cover.
Alarms of the control panel
The control panel has 20 numbered LED indicators. These show
green
when there are no anomalies. If one or more sensors fail, or
detect water, the corresponding LED will light
red
, the valve will close and you will hear an alarm.
Sensor Low Battery
If a water sensor has low battery, it periodically sends a signal to the control panel. The corresponding LED on the control panel will
show
orange
, and the audible alarm will sound, and continue for 15 minutes. The LED will remain
orange
until the condition is
rectified. Water will shut off after 4 low battery signals have been received. The system also outputs a relay contact to remote alarm
system if a low battery alarm occurs. The battery of the corresponding sensor must be replaced, though it should continue to function
for some time. Battery life should be in excess of one year.
Water detection
If any sensor detects water, the corresponding LED will light
red
and the audible alarm sound. The valve will immediately close, and
remain closed until opened with the remote or until the
Reset
button is pressed.
It is best to change
batteries every 12 months.
Batteries should be
changed if the sensors
have been activated
when water is detected.